IFM SD6000
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Systems for the consumption measurement of compressed air & industrial gases |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SD6000 be shipped?
SD6000 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SD6000 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SD6000 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SD6000, subject to availability and destination.
Precise measurement of flow, consumption and medium temperature High accuracy, repeatability and measurement dynamics For detecting compressed air in industrial use With switching output, analogue output and pulse output Clearly visible 4-digit LED display Convenient operation via buttons or parameter setting via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range | 10...1250 l/min; 0.3...103.6 m/s; 0.2...75 m³/h |
| 10...1250 l/min | 0.3...103.6 m/s |
| Process connection | threaded connection R 1/2 external thread DN15 |
Application
| Application | for industrial applications |
| Media | compressed air |
| Note on media | air quality ISO 8573-1; class 141; class 344 |
| Medium temperature[°C] [°C] | 0...60 |
| Pressure rating | 16 bar; 1.6 MPa |
| 16 bar | 1.6 MPa |
| MAWP for applications according to CRN[bar] [bar] | 16 |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | < 110 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 1 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250; (per output) |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Pulse output | consumed quantity meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 10...1250 l/min; 0.3...103.6 m/s; 0.2...75 m³/h |
| 10...1250 l/min | 0.8...103.6 m/s |
| Display range | 0...1500 l/min; 0...124.3 m/s; 0...90 m³/h |
| 0...1500 l/min | 0...124.3 m/s |
| Set point SP | 10...1250 l/min; 0.8...103.6 m/s; 0.6...75 m³/h |
| Reset point rP | 4...1244 l/min; 0.3...103.1 m/s; 0.2...74.6 m³/h |
| 4...1244 l/min | 0.3...103.1 m/s |
| Analogue start point ASP | 0...938 l/min; 0...77.7 m/s; 0...56.3 m³/h |
| 0...938 l/min | 0...77.7 m/s |
| Analogue end point AEP | 312...1250 l/min; 25.9...103.6 m/s; 18.7...75 m³/h |
| 312...1250 l/min | 25.9...103.6 m/s |
| In steps of | 0.001 m³ |
| 1 l/min | 0.1 m/s |
| Pulse value | 0.001...1000000 m³ |
| Pulse length[s] [s] | 0,02...2 |
| Measuring range[°C] [°C] | 0...60 |
| Display range[°C] [°C] | -12...72 |
Accuracy / deviations
| Repeatability[% of the measured value] [% of the measured value] | ± 1,5 |
| Accuracy (in the measuring range) | ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 /; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN15) |
| Accuracy[K] [K] | ± 2; (medium flow in the limit area of the flow measurement range) |
Response times
| Response time[s] [s] | 0.1; (dAP = 0) |
| Damping process value dAP in steps[s] [s] | 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1 |
Software / programming
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 3 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 4.1 |
| Supported DeviceIDs | default; 262 |
| default | 262 |
Operating conditions
| Ambient temperature[°C] [°C] | 0...60 |
| Storage temperature[°C] [°C] | -20...85 |
| Max. relative air humidity[%] [%] | 90 |
| Protection | IP 65 |
Tests / approvals
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| CPA approval | model number; 002TG; accuracy class; -; maximum allowable error; ± 4 % FS; Q (min); 0,2 m³/h; Q (t); -; Q (max); 75 m³/h |
| model number | 002TG |
| accuracy class | - |
| maximum allowable error | ± 4 % FS |
| Q (min) | 0,2 m³/h |
| Q (t) | - |
| Q (max) | 75 m³/h |
| Vibration resistance | DIN EN 68000-2-6; 5 g (55...2000 Hz) |
| DIN EN 68000-2-6 | 5 g (55...2000 Hz) |
| MTTF[years] [years] | 227 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 942.5 |
| Dimensions[mm] [mm] | 300 x 45 x 80.4 |
| Materials | PBT-GF20; NBR; PC; stainless steel (304/1.4301); PTFE; brass coated; FKM; aluminium powder-coated |
| Materials (wetted parts) | stainless steel (304/1.4301); FKM; ceramics glass passivated; PEEK GF30; polyester; aluminium |
| Tightening torque[Nm] [Nm] | 50 |
| Process connection | threaded connection R 1/2 external thread DN15 |
Displays / operating elements
| Display | Display unit; 5 x LED, green (Nl/min, Nm³/h, Nm/s, Nm³, °C); function display; 1 x LED, green; switching status; 2 x LED, yellow; measured values; alphanumeric display, 4-digit; programming; alphanumeric display, 4-digit |
| Display unit | 5 x LED, green (Nl/min, Nm³/h, Nm/s, Nm³, °C) |
| function display | 1 x LED, green |
| switching status | 2 x LED, yellow |
| measured values | alphanumeric display, 4-digit |
| programming | alphanumeric display, 4-digit |
Remarks
| Remarks | MW = measured value; MEW = Final value of the measuring range; Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.; For information about installation and operation please see the operating instructions. |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A |