IFM SD2500
Quick facts
| Availability | Confirmed on request |
| Category | Systems for the consumption measurement of compressed air & industrial gases |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SD2500 be shipped?
SD2500 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SD2500 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SD2500 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SD2500, subject to availability and destination.
Precise measurement of flow, consumption, pressure and medium temperature High accuracy, repeatability and measurement dynamics For detecting compressed air in industrial use Red/green display for clear identification of the acceptable range Display can be rotated for optimum alignment Convenient operation via buttons or parameter setting via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range | 40...11670 l/min; 0.3...84 m/s; 2.5...700 m³/h |
| 40...11670 l/min | 0.3...84 m/s |
| Process connection | threaded connection R 2 external thread DN50 |
Application
| Application | for industrial applications |
| Media | compressed air |
| Medium temperature[°C] [°C] | -10...60 |
| Min. burst pressure | 64 bar; 6.4 MPa |
| 64 bar | 6.4 MPa |
| Pressure rating | 16 bar; 1.6 MPa |
| 16 bar | 1.6 MPa |
| MAWP for applications according to CRN[bar] [bar] | 9.5 |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | < 80 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 1 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Inputs
| Inputs | counter reset |
Outputs
| Output signal | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 150; (per output) |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Pulse output | consumed quantity meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | -10...60 °C; 14...140 °F |
| 40...11670 l/min | 0.3...84 m/s |
| Display range | -24...74 °C; -11.2...165.2 °F |
| 0...14000 l/min | 0...100.8 m/s |
| Resolution | 0.2 °C; 0.5 °F |
| 10 l/min | 0.1 m/s |
| Set point SP | -9.7...60 °C; 14.6...140 °F |
| 100...11660 l/min | 0.7...84 m/s |
| Reset point rP | -10...59.7 °C; 14...139.4 °F |
| 40...11600 l/min | 0.3...83.6 m/s |
| Analogue start point ASP | 0...9330 l/min; 0...67.2 m/s; 0...560 m³/h |
| 0...9330 l/min | 0...67.2 m/s |
| Analogue end point AEP | 2330...11670 l/min; 16.8...84 m/s; 140...700 m³/h |
| 2330...11670 l/min | 16.8...84 m/s |
| Low flow cut-off LFC | 30...120 l/min; 0.2...0.8 m/s; 2...7 m³/h |
| 30...120 l/min | 0.2...0.8 m/s |
| In steps of | 0.1 °C; 0.1 °F |
| 1 l/min | 0.1 m/s |
| Measuring range[bar] [bar] | -1...16 |
| Display range[bar] [bar] | -1...20 |
| Resolution[bar] [bar] | 0.05 |
| Set point SP[bar] [bar] | -0.92...16 |
| Reset point rP[bar] [bar] | -1...15.92 |
| Analogue start point[bar] [bar] | -1...12.8 |
| Analogue end point[bar] [bar] | 2.2...16 |
| In steps of[bar] [bar] | 0.01 |
| 0...100000000 m³ | 0...353146667.2 scf |
| 0.001...10000000 m³ | 0.05...353146667.2 scf |
| Pulse value | 0.001...10000000 m³; 0.05...353146667.2 scf |
| 0.0001 m³ | 0.005 scf |
| Pulse length[s] [s] | 0.002...2 |
| -10...60 °C | 14...140 °F |
| -24...74 °C | -11.2...165.2 °F |
| 0.2 °C | 0.5 °F |
| -9.7...60 °C | 14.6...140 °F |
| -10...59.7 °C | 14...139.4 °F |
| Analogue start point | -10...46 °C; 14...114.8 °F |
| -10...46 °C | 14...114.8 °F |
| Analogue end point | 4...60 °C; 39.2...140 °F |
| 4...60 °C | 39.2...140 °F |
| 0.1 °C | 0.1 °F |
Accuracy / deviations
| Temperature coefficient[1/K] [1/K] | ± 0,07 % MW |
| Accuracy (in the measuring range) | class 141: ± (2 % MW + 0,5 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; at medium temperature 23 °C |
| Repeatability | ± (0,4 % MW + 0,1 % MEW) |
| Repeatability[% of the final value] [% of the final value] | ± 0,2 |
| Characteristics deviation[% of the final value] [% of the final value] | < ± 0,5; (BFSL = Best Fit Straight Line) |
| Greatest TEMPCO of the span[% MEW / 10 K] [% MEW / 10 K] | ± 0,3 |
| Greatest TEMPCO of the zero point[% MEW / 10 K] [% MEW / 10 K] | ± 0,1 |
| Accuracy[K] [K] | ± 0,5; (medium flow in the limit area of the flow measurement range) |
Response times
| Response time[s] [s] | 0.05 |
| Damping process value dAP[s] [s] | 0...5 |
| Dynamic response T05 / T09[s] [s] | T09 = 0,5 |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Common - I&D; Identification and Diagnosis; Function; Measurement data, standard resolution |
| Common - I&D | Identification and Diagnosis |
| Function | Measurement data, standard resolution |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 8 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 7.2 |
| Supported DeviceIDs | default; 870 |
| default | 870 |
Operating conditions
| Ambient temperature[°C] [°C] | 0...60 |
| Storage temperature[°C] [°C] | -20...85 |
| Max. relative air humidity[%] [%] | 90 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | DIN EN 60947-5-9 |
| CPA approval | model number; 001TG; accuracy class; -; maximum allowable error; ± 2,5 % FS; Q (min); 0,05 m³/h; Q (t); -; Q (max); 700 m³/h |
| model number | 001TG |
| accuracy class | - |
| maximum allowable error | ± 2,5 % FS |
| Q (min) | 0,05 m³/h |
| Q (t) | - |
| Q (max) | 700 m³/h |
| Vibration resistance | DIN EN 68000-2-6; 5 g (10...2000 Hz) |
| DIN EN 68000-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 183 |
| UL approval | UL approval no.; I012; File number UL; E174189 |
| UL approval no. | I012 |
| File number UL | E174189 |
| Pressure Equipment Directive | Sound engineering practice; can be used for stable gases fluid group 2 |
Mechanical data
| Weight[g] [g] | 2650.5 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 475 x 60.3 x 109.7 |
| Materials | PBT+PC-GF30; PPS GF40; stainless steel (304/1.4301); stainless steel (303/1.4305); steel (1.5523) galvanised; 2.0401 (brass / CW614N); FKM |
| Materials (wetted parts) | stainless steel (304/1.4301); stainless steel (303/1.4305); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate |
| Process connection | threaded connection R 2 external thread DN50 |
Displays / operating elements
| Display | colour display 1,44", 128 x 128 pixels; 2 x LED, yellow |
Remarks
| Remarks | MW = measured value; MEW = Final value of the measuring range; Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.; For information about installation and operation please see the operating instructions. |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A |