Available on request

IFM SD0550

MPN: SD0550 · Brand: IFM
Price on request
12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can SD0550 be shipped?

SD0550 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up SD0550 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for SD0550 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SD0550, subject to availability and destination.

Precise measurement of flow, consumption and medium temperature High accuracy, repeatability and measurement dynamics For detecting compressed air in industrial use With switching output, analogue output and pulse output Clearly visible 4-digit LED display Convenient operation via buttons or parameter setting via IO-Link

Specifications

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range1...250 l/min; 0.3...82.9 m/s; 0.04...15 m³/h
1...250 l/min0.3...82.9 m/s
Process connectionthreaded connection G 1/4 internal thread DN8

Application

Applicationfor industrial applications
Mediaair
Medium temperature[°C] [°C]0...40
Pressure rating2 bar; 0.2 MPa
2 bar0.2 MPa

Electrical data

Operating voltage[V] [V]18...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 110
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]1

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250; (per output)
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Pulse outputconsumed quantity meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range1...250 l/min; 0.3...82.9 m/s; 0.04...15 m³/h
1...250 l/min0.3...82.9 m/s
Display range0...300 l/min; 0...99.5 m/s; 0...18 m³/h
0...300 l/min0...99.5 m/s
Set point SP2...250 l/min; 0.7...82.9 m/s; 0.12...15 m³/h
2...250 l/min0.7...82.9 m/s
Reset point rP1...249 l/min; 0.3...82.5 m/s; 0.04...14.92 m³/h
1...249 l/min0.3...82.5 m/s
Analogue start point ASP0...187.5 l/min; 0...62.2 m/s; 0...11.26 m³/h
0...187.5 l/min0...62.2 m/s
Analogue end point AEP62.5...250 l/min; 20.7...82.9 m/s; 3.74...15 m³/h
62.5...250 l/min20.7...82.9 m/s
In steps of0.001 m³
0.5 l/min0.1 m/s
Pulse value0.001...1000000 m³
Pulse length[s] [s]0,1...2
Measuring range[°C] [°C]0...60
Display range[°C] [°C]-12...72

Accuracy / deviations

Repeatability[% of the measured value] [% of the measured value]± 1,5
Accuracy (in the measuring range)± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 /; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN8)
Accuracy[K] [K]± 2; (medium flow in the limit area of the flow measurement range)

Response times

Response time[s] [s]0.1; (dAP = 0)
Damping process value dAP in steps[s] [s]0 - 0,2 - 0,4 - 0,6 - 0,8 - 1

Software / programming

Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 CDV
SIO modeyes
Required master port typeA
Process data analogue3
Process data binary2
Min. process cycle time[ms] [ms]4.1
Supported DeviceIDsdefault; 1329
default1329

Operating conditions

Ambient temperature[°C] [°C]0...40
Storage temperature[°C] [°C]-20...85
Max. relative air humidity[%] [%]90

Tests / approvals

EMCDIN EN 61000-6-2; DIN EN 61000-6-3
Vibration resistanceDIN EN 68000-2-6; 5 g (55...2000 Hz)
DIN EN 68000-2-65 g (55...2000 Hz)
MTTF[years] [years]220
UL approvalFile number UL; E174189
File number ULE174189
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]955.8
Housingrectangular
Dimensions[mm] [mm]182.3 x 45 x 74.5
MaterialsPBT-GF20; NBR; PC; stainless steel (304/1.4301); PTFE; brass coated; FKM; aluminium powder-coated
Materials (wetted parts)stainless steel (304/1.4301); FKM; ceramics glass passivated; PEEK GF30; polyester; aluminium; cyanoacrylate
Process connectionthreaded connection G 1/4 internal thread DN8
Length[mm] [mm]182.3

Displays / operating elements

DisplayDisplay unit; 5 x LED, green (Nl/min, Nm³/h, Nm/s, Nm³, °C); function display; 1 x LED, green; switching status; 2 x LED, yellow; measured values; alphanumeric display, 4-digit; programming; alphanumeric display, 4-digit
Display unit5 x LED, green (Nl/min, Nm³/h, Nm/s, Nm³, °C)
function display1 x LED, green
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit

Remarks

RemarksMW = measured value; MEW = Final value of the measuring range; Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.; For information about installation and operation please see the operating instructions.; Note: no medical device!; Permanent availability, safe switching-off or self-diagnosis function cannot be confirmed. The manufacturer of the machine/equipment is responsible for ensuring this, if required.
Notescustomer-specific
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More IFM parts

IFM O8H205Available on requestIFM O8H205
MPN: O8H205 · IFM
Price on request
Request a quote
IFM O8H206Available on requestIFM O8H206
MPN: O8H206 · IFM
Price on request
Request a quote
IFM O8H207Available on requestIFM O8H207
MPN: O8H207 · IFM
Price on request
Request a quote
IFM O8H202Available on requestIFM O8H202
MPN: O8H202 · IFM
Price on request
Request a quote