IFM SBZ224
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Mechatronic flow meters in high-pressure applications |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SBZ224 be shipped?
SBZ224 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SBZ224 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SBZ224 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SBZ224, subject to availability and destination.
Robust housing with very high pressure rating Resistant to cleaning agents thanks to stainless steel components Flexible use thanks to IO-Link, analogue, switching and frequency output Integrated temperature sensor saves hardware costs Convenient operation via buttons or parameter setting via IO-Link IO-Link enables documentation of cleaning operations
Specifications
Product characteristics
| Measuring range | 1...50 l/min; 0.06...3 m³/h; 16...793 gph; 0.26...13.2 gpm |
| 1...50 l/min | 0.06...3 m³/h |
| Process connection | threaded connection G 1/2 internal thread |
Application
| Special feature | Gold-plated contacts |
| Media | Liquids; water; glycol solutions; coolants |
| Medium temperature[°C] [°C] | -10...100 |
| Pressure rating | 200 bar; 20 MPa |
| 200 bar | 20 MPa |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 3 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; frequency signal; IO-Link |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Max. current load per output[mA] [mA] | 150; (200: ...60 °C; Ambient temperature; 250: ...40 °C; Ambient temperature) |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | 500 |
| Short-circuit protection | yes |
| Overload protection | yes |
| Frequency of the output[Hz] [Hz] | 0...10000 |
Measuring/setting range
| Measuring range | -10...100 °C; 14...212 °F |
| 1...50 l/min | 0.06...3 m³/h |
| Display range | -32...122 °C; -25.6...251.6 °F |
| 0...60 l/min | 0...3.6 m³/h |
| Resolution | 0.1 °C; 0.1 °F |
| 0.01 l/min | 0.001 m³/h |
| Set point SP | -9.3...100 °C; 15.2...212 °F |
| 0.35...50 l/min | 0.02...3 m³/h |
| Reset point rP | -10...99.3 °C; 14...210.8 °F |
| 0...49.65 l/min | 0...2.98 m³/h |
| Frequency end point, FEP | 12...100 °C; 53.6...212 °F |
| 3.35...50 l/min | 0.2...3 m³/h |
| In steps of | 0.1 °C; 0.2 °F |
| 0.05 l/min | 0.005 m³/h |
| Frequency at the end point FRP[Hz] [Hz] | 10...10000 |
| In steps of[Hz] [Hz] | 10 |
| Measuring dynamics | 1:50 |
| -10...100 °C | 14...212 °F |
| -32...122 °C | -25.6...251.6 °F |
| 0.1 °C | 0.2 °F |
| -9.3...100 °C | 15.2...212 °F |
| -10...99.3 °C | 14...210.8 °F |
| Frequency start point, FSP | -10...78 °C; 14...172.4 °F |
| -10...78 °C | 14...172.4 °F |
| 12...100 °C | 53.6...212 °F |
Accuracy / deviations
| Accuracy (in the measuring range) | ± (4 % MW + 1 % MEW); (Q > 1 l/min; medium and operating temperature: + 22 °C ± 4K; Installation position upright) |
| Repeatability | ± 1 % MEW |
| Temperature drift | 0,029 °C / K |
| Accuracy[K] [K] | 3 K (25 °C; Q > 1 l/min) |
Response times
| Response time[s] [s] | 0.01 |
| Damping process value dAP[s] [s] | 0...5 |
| In steps of[s] [s] | 0.1 |
| Damping for the analogue output dAA[s] [s] | 0...5 |
| Dynamic response T05 / T09[s] [s] | T09 = 120 (Q > 1 l/min) |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/frequency output; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour; calibration factor |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable; Function; Device diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 2 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 3.2 |
| Supported DeviceIDs | default; 1447 |
| default | 1447 |
Operating conditions
| Ambient temperature[°C] [°C] | 0...60 |
| Note on ambient temperature | medium temperature < 80 °C; medium temperature < 100 °C: 0...40 °C |
| Storage temperature[°C] [°C] | -15...80 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27; 20 g (11 ms) |
| DIN EN 60068-2-27 | 20 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 5 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 170 |
| Pressure Equipment Directive | Sound engineering practice |
Mechanical data
| Weight[g] [g] | 1734.3 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 175.5 x 59 x 39 |
| Materials | stainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC |
| Materials (wetted parts) | stainless steel (316 / 1.4401); stainless steel (316L/1.4404); O-ring: FKM |
| Process connection | threaded connection G 1/2 internal thread |
| Switching cycles mechanical | 10 million |
Displays / operating elements
| Display | Display unit; 6 x LED, green; switching status; 2 x LED, yellow; measured values; alphanumeric display, red/green alternating indication 4-digit; programming; alphanumeric display, 4-digit |
| Display unit | 6 x LED, green |
| switching status | 2 x LED, yellow |
| measured values | alphanumeric display, red/green alternating indication 4-digit |
| programming | alphanumeric display, 4-digit |
Remarks
| Remarks | Recommendation: use a 200-micron filter.; All data refer to water (20 °C).; Installation position upright; MW = measured value; MEW = Final value of the measuring range |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |