IFM SB9233
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Mechatronic sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SB9233 be shipped?
SB9233 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SB9233 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SB9233 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SB9233, subject to availability and destination.
Fast flow or temperature changes do not affect the measurement High measurement dynamics reduces type versions No inlet and output pipe lengths required Specifically adjusted to oil for optimum measurement results Convenient operation via buttons or parameter setting via IO-Link
Specifications
Product characteristics
| Measuring range | 0.5...25 l/min; 0.03...1.5 m³/h; 8...396.5 gph; 0.13...6.6 gpm |
| 0.5...25 l/min | 0.03...1.5 m³/h |
| Process connection | threaded connection G 3/4 internal thread |
Application
| Special feature | Gold-plated contacts |
| Media | Liquids; oils (viscosity 32 mm²/s at 40 °C) |
| Medium temperature[°C] [°C] | -10...100 |
| Pressure rating | 100 bar; 10 MPa |
| 100 bar | 10 MPa |
| Note on pressure rating | at medium temperature >70°C: 80 bar / 8 MPa |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 3 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; frequency signal; IO-Link |
| Output function | parameterisable |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Max. current load per output[mA] [mA] | 150; (200: ...60 °C; Ambient temperature; 250: ...40 °C; Ambient temperature) |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | 500 |
| Short-circuit protection | yes |
| Overload protection | yes |
| Frequency of the output[Hz] [Hz] | 0...10000 |
Measuring/setting range
| Measuring range | -10...100 °C; 14...212 °F |
| 0.5...25 l/min | 0.03...1.5 m³/h |
| Display range | -32...122 °C; -25.6...251.6 °F |
| 0...30 l/min | 0...1.8 m³/h |
| Resolution | 0.1 °C; 0.1 °F |
| 0.01 l/min | 0.001 m³/h |
| Set point SP | -9.3...100 °C; 15.2...212 °F |
| 0.16...25 l/min | 0.01...1.5 m³/h |
| Reset point rP | -10...99.3 °C; 14...210.8 °F |
| 0...24.84 l/min | 0...1.49 m³/h |
| Frequency end point, FEP | 12...100 °C; 53.6...212 °F |
| 1.66...25 l/min | 0.1...1.5 m³/h |
| In steps of | 0.1 °C; 0.2 °F |
| 0.02 l/min | 0.002 m³/h |
| Frequency at the end point FRP[Hz] [Hz] | 10...10000 |
| In steps of[Hz] [Hz] | 10 |
| Measuring dynamics | 1:50 |
| -10...100 °C | 14...212 °F |
| -32...122 °C | -25.6...251.6 °F |
| 0.1 °C | 0.2 °F |
| -9.3...100 °C | 15.2...212 °F |
| -10...99.3 °C | 14...210.8 °F |
| Frequency start point, FSP | -10...78 °C; 14...172.4 °F |
| -10...78 °C | 14...172.4 °F |
| 12...100 °C | 53.6...212 °F |
Accuracy / deviations
| Accuracy (in the measuring range) | ± 5 % MEW; (Q > 1 l/min; 20...70 °C Medium temperature) |
| Repeatability | ± 1 % MEW |
| Temperature drift | 0,029 °C / K |
| Accuracy[K] [K] | 3 K (25°C; Q > 1 l/min) |
Response times
| Response time[s] [s] | 0.01 |
| Damping process value dAP[s] [s] | 0...5 |
| In steps of[s] [s] | 0.1 |
| Damping for the analogue output dAA[s] [s] | 0...5 |
| Dynamic response T05 / T09[s] [s] | T09 = 120 (Q > 1 l/min) |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/frequency output; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour; calibration factor |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable; Function; Device diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 2 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 3.2 |
| Supported DeviceIDs | default; 1044 |
| default | 1044 |
Operating conditions
| Ambient temperature[°C] [°C] | 0...60 |
| Note on ambient temperature | medium temperature < 80 °C; medium temperature < 100 °C: 0...40 °C |
| Storage temperature[°C] [°C] | -15...80 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27; 20 g (11 ms) |
| DIN EN 60068-2-27 | 20 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 5 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 145 |
| UL approval | UL approval no.; I005; File number UL; E174189 |
| UL approval no. | I005 |
| File number UL | E174189 |
| Pressure Equipment Directive | Sound engineering practice |
Mechanical data
| Weight[g] [g] | 997 |
| Materials | stainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated |
| Materials (wetted parts) | stainless steel (316 / 1.4401); stainless steel (316L/1.4404); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM |
| Process connection | threaded connection G 3/4 internal thread |
| Switching cycles mechanical | 10 million |
Displays / operating elements
| Display | Display unit; 6 x LED, green; switching status; 2 x LED, yellow; measured values; alphanumeric display, red/green alternating indication 4-digit; programming; alphanumeric display, 4-digit |
| Display unit | 6 x LED, green |
| switching status | 2 x LED, yellow |
| measured values | alphanumeric display, red/green alternating indication 4-digit |
| programming | alphanumeric display, 4-digit |
Remarks
| Remarks | Recommendation: use a 200-micron filter.; All data refer to oil with the following nominal viscosity: 32 cSt, 40 °C ± 3 K; MW = measured value; MEW = Final value of the measuring range |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |