Quick facts
| Availability | Confirmed on request |
| Category | Compact flow sensors with display |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SA5014 be shipped?
SA5014 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SA5014 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SA5014 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SA5014, subject to availability and destination.
Measurement of flow and temperature at the same time Optimised for water, oils and air Clearly visible 4-digit LED display With two scalable analogue outputs The process connection can be rotated for optimum alignment
Specifications
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 2 |
| Process connection | threaded connection M18 x 1,5 internal thread |
Application
| Special feature | Gold-plated contacts |
| Media | water; glycol solutions; air; oils |
| Note on media | low-viscosity oils with viscosity: ≤ 40 mm²/s (104 °F); high-viscosity oils with viscosity: > 40 mm²/s (104 °F) |
| Medium temperature[°F] [°F] | -4...194 |
| Pressure rating | 100 bar; 10 MPa |
| 100 bar | 10 MPa |
| MAWP for applications according to CRN | 100 bar; 10 MPa |
Electrical data
| Operating voltage[V] [V] | 18...30 DC |
| Current consumption[mA] [mA] | < 100 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 10 |
| Measuring principle | calorimetric |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 2 |
Outputs
| Total number of outputs | 2 |
| Output signal | analogue signal |
| Number of analogue outputs | 2 |
| Analogue current output[mA] [mA] | 4...20; (scalable) |
| Max. load[Ω] [Ω] | 350 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Probe length L[mm] [mm] | 45 |
| Operating mode | relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended; Factory setting: relative) |
| Resolution[ft/s] [ft/s] | 2 |
| Analogue start point ASP[ft/s] [ft/s] | 0...264 |
| Analogue end point AEP[ft/s] [ft/s] | 64...328 |
| Measuring range[°F] [°F] | -4...194 |
| Resolution[°F] [°F] | 0.5 |
| Analogue start point[°F] [°F] | -4...169 |
| Analogue end point[°F] [°F] | 39...212 |
| In steps of[°F] [°F] | 0.5 |
| Setting range[ft/s] [ft/s] | 6...656 |
| Greatest sensitivity[ft/s] [ft/s] | 6...328 |
Accuracy / deviations
| Temperature drift[cm/s x 1/K] [cm/s x 1/K] | 0,01 fps x 1/K (< 68 °F; > 158 °F) |
| Temperature gradient[K/min] [K/min] | 100 |
| Repeatability | 0,05 m/s; (water; flow velocity: 0,05...3 m/s) |
| Accuracy | ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 68...158 °F; inlet length: 5 ft; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.) |
| Temperature drift | ± 0,003 K/°F |
| Accuracy[K] [K] | ± 0,3 / ± 1; (water; flow velocity: 1...9,85 fps / air; flow velocity: > 32,8 fps) |
Response times
| Response time[s] [s] | 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09) |
| Dynamic response T05 / T09[s] [s] | 1,5 (T09); (water; flow velocity: 0,3...3 m/s) |
Software / programming
| Parameter setting options | medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour |
Operating conditions
| Ambient temperature[°F] [°F] | -40...176 |
| Storage temperature[°F] [°F] | -40...212 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | DIN EN 60947-5-9 |
| Shock resistance | DIN EN 60068-2-27; 50 g (11 ms) |
| DIN EN 60068-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 20 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 179 |
| UL approval | UL approval no.; I004; File number UL; E174189 |
| UL approval no. | I004 |
| File number UL | E174189 |
Mechanical data
| Weight[g] [g] | 278 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 34 / L = 142 |
| Materials | stainless steel (316L/1.4404); stainless steel (301/1.4310); PBT-GF20; PBT-GF30 |
| Materials (wetted parts) | stainless steel (316L/1.4404); Gasket: FKM |
| Process connection | threaded connection M18 x 1,5 internal thread |
| Probe diameter[mm] [mm] | 8 |
| Installation length EL[mm] [mm] | 45 |
Displays / operating elements
| Display | Display unit; 6 x LED, green (%, m/s, l/min, m³/h, °C, 10³); measured values; alphanumeric display, red/green 4-digit |
| Display unit | 6 x LED, green (%, m/s, l/min, m³/h, °C, 10³) |
| measured values | alphanumeric display, red/green 4-digit |
Remarks
| Remarks | MW = measured value; MEW = Final value of the measuring range |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |