Available on request

IFM SA5004

MPN: SA5004 · Brand: IFM
Price on request
12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryCompact flow sensors with display
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can SA5004 be shipped?

SA5004 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up SA5004 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for SA5004 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SA5004, subject to availability and destination.

Measurement of flow and temperature at the same time Optimised for water, oils and air Clearly visible 4-digit LED display With two scalable analogue outputs The process connection can be rotated for optimum alignment

Specifications

Product characteristics

Number of inputs and outputsNumber of analogue outputs: 2
Process connectionthreaded connection M18 x 1,5 internal thread

Application

Special featureGold-plated contacts
Mediawater; glycol solutions; air; oils
Note on medialow-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C); high-viscosity oils with viscosity: > 40 mm²/s (40 °C)
Medium temperature[°C] [°C]-20...90
Pressure rating100 bar; 10 MPa
100 bar10 MPa
MAWP for applications according to CRN[bar] [bar]100

Electrical data

Operating voltage[V] [V]18...30 DC
Current consumption[mA] [mA]< 100
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]10
Measuring principlecalorimetric

Inputs / outputs

Number of inputs and outputsNumber of analogue outputs: 2

Outputs

Total number of outputs2
Output signalanalogue signal
Number of analogue outputs2
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]350
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Probe length L[mm] [mm]45
Operating moderelative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended; Factory setting: relative)
Measuring range[°C] [°C]-20...90
Resolution[°C] [°C]0.2
Analogue start point[°C] [°C]-20...76
Analogue end point[°C] [°C]4...100
In steps of[°C] [°C]0.2
Setting range[m/s] [m/s]2...200
Greatest sensitivity[m/s] [m/s]30...100

Accuracy / deviations

Temperature drift[cm/s x 1/K] [cm/s x 1/K]0,003 m/s x 1/K (< 20 °C; > 70 °C)
Temperature gradient[K/min] [K/min]100
Repeatability0,05 m/s; (water; flow velocity: 0,05...3 m/s)
Accuracy± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20...70 °C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.)
Temperature drift± 0,005 K/°C
Accuracy[K] [K]± 0,3 / ± 1; (water; flow velocity: 0,3...3 m/s / air; flow velocity: > 10 m/s)

Response times

Response time[s] [s]0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09)
Dynamic response T05 / T09[s] [s]1,5 (T09); (water; flow velocity: 0,3...3 m/s)

Software / programming

Parameter setting optionsmedium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour

Operating conditions

Ambient temperature[°C] [°C]-40...80
Storage temperature[°C] [°C]-40...100
ProtectionIP 65; IP 67

Tests / approvals

EMCDIN EN 60947-5-9
Shock resistanceDIN EN 60068-2-27; 50 g (11 ms)
DIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-6; 20 g (10...2000 Hz)
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years] [years]180
UL approvalUL approval no.; I004; File number UL; E174189
UL approval no.I004
File number ULE174189

Mechanical data

Weight[g] [g]281
Housingcylindrical
Dimensions[mm] [mm]Ø 34 / L = 142
Materialsstainless steel (316L/1.4404); stainless steel (301/1.4310); PBT-GF20; PBT-GF30
Materials (wetted parts)stainless steel (316L/1.4404); Gasket: FKM
Process connectionthreaded connection M18 x 1,5 internal thread
Probe diameter[mm] [mm]8
Installation length EL[mm] [mm]45

Displays / operating elements

DisplayDisplay unit; 6 x LED, green (%, m/s, l/min, m³/h, °C, 10³); measured values; alphanumeric display, red/green 4-digit
Display unit6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)
measured valuesalphanumeric display, red/green 4-digit

Remarks

RemarksMW = measured value; MEW = Final value of the measuring range
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More IFM parts

IFM O8H205Available on requestIFM O8H205
MPN: O8H205 · IFM
Price on request
Request a quote
IFM O8H206Available on requestIFM O8H206
MPN: O8H206 · IFM
Price on request
Request a quote
IFM O8H207Available on requestIFM O8H207
MPN: O8H207 · IFM
Price on request
Request a quote
IFM O8H202Available on requestIFM O8H202
MPN: O8H202 · IFM
Price on request
Request a quote