IFM SA4300
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Compact flow sensors with display |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SA4300 be shipped?
SA4300 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SA4300 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SA4300 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SA4300, subject to availability and destination.
Measurement of flow and temperature at the same time Optimised for water, oils and air Red/green display for clear identification of the acceptable range With switching output, analogue signal and IO-Link The process connection can be rotated for optimum alignment Convenient operation via buttons or parameter setting via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Process connection | clamp adapter Ø 8 mm |
Application
| Special feature | Gold-plated contacts |
| Media | water; glycol solutions; air; oils |
| Note on media | low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C); high-viscosity oils with viscosity: > 40 mm²/s (40 °C) |
| Medium temperature[°C] [°C] | -20...100 |
| Pressure rating | 50 bar; 5 MPa |
| 50 bar | 5 MPa |
| MAWP for applications according to CRN[bar] [bar] | 50 |
Electrical data
| Operating voltage[V] [V] | 18...30 DC |
| Current consumption[mA] [mA] | < 100 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 10 |
| Measuring principle | calorimetric |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; frequency signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 250 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20; (scalable) |
| Max. load[Ω] [Ω] | 350 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Frequency of the output[Hz] [Hz] | 0...1000 |
Measuring/setting range
| Probe length L[mm] [mm] | 200 |
| Operating mode | relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended; Factory setting: relative) |
| Measuring range[°C] [°C] | -20...100 |
| Resolution[°C] [°C] | 0.2 |
| Setting range[m/s] [m/s] | 2...200 |
| Greatest sensitivity[m/s] [m/s] | 30...100 |
Accuracy / deviations
| Temperature drift[cm/s x 1/K] [cm/s x 1/K] | 0,003 m/s x 1/K (< 20 °C; > 70 °C) |
| Temperature gradient[K/min] [K/min] | 100 |
| Repeatability | 0,05 m/s; (water; flow velocity: 0,05...3 m/s) |
| Accuracy | ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20...70 °C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.) |
| Temperature drift | ± 0,005 K/°C |
| Accuracy[K] [K] | ± 0,3 / ± 1; (water; flow velocity: 0,3...3 m/s / air; flow velocity: > 10 m/s) |
Response times
| Response time[s] [s] | 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09) |
| Dynamic response T05 / T09[s] [s] | 1,5 (T09); (water; flow velocity: 0,3...3 m/s) |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable; Function; Device diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 2 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 3 |
| Supported DeviceIDs | Factory setting / ModE = (REL); 533; ModE = (GAS); 547; ModE = (LIQU); 540 |
| Factory setting / ModE = (REL) | 533 |
| ModE = (GAS) | 547 |
| ModE = (LIQU) | 540 |
Operating conditions
| Ambient temperature[°C] [°C] | -40...80 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | DIN EN 60947-5-9 |
| Shock resistance | DIN EN 60068-2-27; 50 g (11 ms) |
| DIN EN 60068-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 2 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 2 g (10...2000 Hz) |
| MTTF[years] [years] | 180 |
| UL approval | UL approval no.; I017; File number UL; E174189 |
| UL approval no. | I017 |
| File number UL | E174189 |
Mechanical data
| Weight[g] [g] | 345.5 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 8 / L = 292 |
| Materials | stainless steel (316L/1.4404); PBT-GF20; PBT-GF30 |
| Materials (wetted parts) | stainless steel (316L/1.4404) |
| Process connection | clamp adapter Ø 8 mm |
Displays / operating elements
| Display | Display unit; 6 x LED, green (%, m/s, l/min, m³/h, °C, 10³); switching status; 2 x LED, yellow; measured values; alphanumeric display, red/green 4-digit |
| Display unit | 6 x LED, green (%, m/s, l/min, m³/h, °C, 10³) |
| switching status | 2 x LED, yellow |
| measured values | alphanumeric display, red/green 4-digit |
Remarks
| Remarks | MW = measured value; MEW = Final value of the measuring range |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |