IFM PY9000
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PY9000 be shipped?
PY9000 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PY9000 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PY9000 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PY9000, subject to availability and destination.
Suited for use in homogeniser processes Intuitive, user-friendly handling Analogue output and switching output for alarm function Integrated, clearly readable display With long-term stability thanks to high overload protection
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range[bar] [bar] | 0...600 |
| Process connection | homogeniser connection |
Application
| Special feature | Gold-plated contacts |
| Application | flush mountable for the food and beverage industry |
| Media | liquids and gases |
| Conditionally suitable for | For gaseous media the application is limited to max. 25 bar. |
| Medium temperature[°C] [°C] | -25...100; (145 max 1h) |
| Min. burst pressure | 1200 bar; 120 MPa |
| 1200 bar | 120 MPa |
| Pressure rating | 800 bar; 80 MPa |
| 800 bar | 80 MPa |
| Type of pressure | relative pressure |
Electrical data
| Operating voltage[V] [V] | 20...30 DC |
| Current consumption[mA] [mA] | < 65 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 0.3 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250 |
| Switching frequency DC[Hz] [Hz] | < 170 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20; (scalable 1:4) |
| Max. load[Ω] [Ω] | (Ub - 10 V) / 20 mA |
| Analogue voltage output[V] [V] | 0...10; (scalable 1:4) |
| Min. load resistance[Ω] [Ω] | 2000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range[bar] [bar] | 0...600 |
| Set point SP[bar] [bar] | 6...600 |
| Reset point rP[bar] [bar] | 3...597 |
| Analogue start point[bar] [bar] | 0...240 |
| Analogue end point[bar] [bar] | 150...600 |
| In steps of[bar] [bar] | 3 |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 1,0; (Turn down 1:1) |
| Repeatability[% of the span] [% of the span] | < ± 0,25; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation[% of the span] [% of the span] | < ± 1,0; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
| Linearity deviation[% of the span] [% of the span] | < ± 0,5; (Turn down 1:1) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 1,0; (Turn down 1:1) |
| Long-term stability[% of the span] [% of the span] | < ± 0,25; (Turn down 1:1; per year) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (0...80 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (0...80 °C) |
Response times
| Response time[ms] [ms] | < 3 |
| Damping process value dAP[s] [s] | 0...4 |
| Damping for the analogue output dAA in steps[s] [s] | 0 - 0; 1 - 0; 5 - 2 |
| Max. response time analogue output[ms] [ms] | 3 |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span |
Operating conditions
| Ambient temperature[°C] [°C] | -25...80 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 67 |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; EN 61000-4-4 Burst; 2 kV; EN 61000-4-5 Surge; 0,5/1 kV; EN 61000-4-6 HF conducted; 10 V |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-5 Surge | 0,5/1 kV |
| EN 61000-4-6 HF conducted | 10 V |
| Shock resistance | DIN EN 60068-2-27; 50 g (11 ms) |
| DIN EN 60068-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 20 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 145 |
Mechanical data
| Weight[g] [g] | 384 |
| Materials | stainless steel (304/1.4301); stainless steel (316L/1.4404); PC; PBT; PA; FKM; EPDM/X |
| Materials (wetted parts) | stainless steel (316L/1.4404); ceramics (99.9 % Al2O3); FKM |
| Min. pressure cycles | 50 million |
| Process connection | homogeniser connection |
Displays / operating elements
| Display | Display unit; 3 x LED, green; switching status; 2 x LED, yellow; function display; alphanumeric display, 4-digit; measured values; alphanumeric display, 4-digit |
| Display unit | bar; psi; MPa |
| switching status | 2 x LED, yellow |
| function display | alphanumeric display, 4-digit |
| measured values | alphanumeric display, 4-digit |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |