Quick facts

AvailabilityConfirmed on request
CategoryTwo switching outputs
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can PV8003 be shipped?

PV8003 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up PV8003 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for PV8003 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PV8003, subject to availability and destination.

Compact housing for use where space is restricted Very high overpressure and vacuum resistance Robust stainless steel housing with high shock and vibration resistance Two programmable switching outputs, one of them with IO-Link communication interface Integrated temperature measurement via IO-Link User-friendly communication and parameterisation via IO-Link

Specifications

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2
Measuring range-1...25 bar; -14.6...362.6 psi; -0.1...2.5 MPa
-1...25 bar-14.6...362.6 psi
Process connectionthreaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5

Application

Measuring elementmetallic thin film cell
Applicationfor industrial applications
Medialiquids and gases
Medium temperature[°C] [°C]-40...90
Min. burst pressure600 bar; 8700 psi; 60 MPa
600 bar8700 psi
Pressure rating65 bar; 940 psi; 6.5 MPa
65 bar940 psi
Note on pressure ratingstatic
Vacuum resistance-1000 mbar; -0.1 MPa
-1000 mbar-0.1 MPa
Type of pressurerelative pressure

Electrical data

Operating voltage[V] [V]18...30 DC
Current consumption[mA] [mA]< 15
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]< 0.3

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2

Outputs

Total number of outputs2
Output signalswitching signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]100
Switching frequency DC[Hz] [Hz]< 130
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range-40...90 °C; -40...194 °F
-1...25 bar-14.6...362.6 psi
Set point SP-38...90 °C; -36.4...194 °F
-0.75...25 bar-10.8...362.6 psi
Reset point rP-40...88 °C; -40...190.4 °F
-0.87...24.88 bar-12.7...360.8 psi
In steps of0.1 °C; 0.1 °F
0.01 bar0.1 psi
Factory settingSP1 = 6.25 bar; rP1 = 5.75 bar; ou1 = Hno;; SP2 = 18.75 bar; rP2 = 18.25 bar; ou2 = Hno;; dS1/dS2 = 0 ms; dr1/dr2 = 0 ms; coF = 0 %; P-n = PnP; dAP= 60 ms
SP1 = 6.25 barrP1 = 5.75 bar
SP2 = 18.75 barrP2 = 18.25 bar
dS1/dS2 = 0 msdr1/dr2 = 0 ms
coF = 0 %P-n = PnP
-40...90 °C-40...194 °F
-38...90 °C-36.4...194 °F
-40...88 °C-40...190.4 °F
0.1 °C0.1 °F

Accuracy / deviations

Switch point accuracy[% of the span] [% of the span]< ± 0,5 (nach DIN EN 61298-2)
Repeatability[% of the span] [% of the span]< ± 0,05; (with temperature fluctuations < 10 K)
Characteristics deviation[% of the span] [% of the span]< ± 0,5; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1)
Linearity deviation[% of the span] [% of the span]< ± 0,1 (BFSL) / < ± 0,2 (LS)
Hysteresis deviation[% of the span] [% of the span]< ± 0,2
Long-term stability[% of the span] [% of the span]< ± 0,1; (per 6 months)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]< 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]< 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C)
Accuracy[K] [K]± 2 K + (0.1 x (ambient temperature - medium temperature))
Notes on the accuracy / deviationtemperature range -10 to 80 °C

Response times

Response time[ms] [ms]< 3
Dynamic response T05 / T09[s] [s]< 80 / < 210 ( under ifm reference conditions )

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesCommon - I&D; Identification and Diagnosis; Function; Measurement data, standard resolution
Common - I&DIdentification and Diagnosis
FunctionMeasurement data, standard resolution
SIO modeyes
Required master port typeA
Process data analogue5
Process data binary2
Min. process cycle time[ms] [ms]4.5
IO-Link resolution pressure[bar] [bar]0.01
IO-Link resolution temperature[K] [K]0.2
IO-Link process data (cyclical)pressure; 16; temperature; 16; device status; 4; binary switching information; 2
pressure16
temperature16
device status4
binary switching information2
IO-Link functions (acyclical)application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter; Temperature peak counter
Supported DeviceIDsdefault; 1211
default1211

Operating conditions

Ambient temperature[°C] [°C]-40...90
Storage temperature[°C] [°C]-40...100
ProtectionIP 67; IP 69K

Tests / approvals

EMCDIN EN 61326-1
Shock resistanceDIN EN 60068-2-27; 500 g (1 ms)
DIN EN 60068-2-27500 g (1 ms)
Vibration resistanceDIN EN 60068-2-6; 20 g (10...2000 Hz)
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years] [years]668
UL approvalUL approval no.; J037; File number UL; E174189
UL approval no.J037
File number ULE174189
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]56.3
Housingcylindrical
Dimensions[mm] [mm]Ø 19 / L = 66
Materialsstainless steel (630/1.4542/17-4 PH); stainless steel (316L/1.4404); PEI
Materials (wetted parts)stainless steel (303/1.4305); stainless steel (630/1.4542/17-4 PH)
Min. pressure cycles60 million; (at 1.2 times nominal pressure)
Tightening torque[Nm] [Nm]25...35; (recommended tightening torque; depends on the lubrication, the seal and the pressure load)
Process connectionthreaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5
Process connection sealingFKM (DIN EN ISO 1179-2)
Restrictor element integratedyes

Remarks

RemarksBFSL = Best Fit Straight Line; LS = limit value setting
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More IFM parts

IFM O8H205Available on requestIFM O8H205
MPN: O8H205 · IFM
Price on request
Request a quote
IFM O8H206Available on requestIFM O8H206
MPN: O8H206 · IFM
Price on request
Request a quote
IFM O8H207Available on requestIFM O8H207
MPN: O8H207 · IFM
Price on request
Request a quote
IFM O8H202Available on requestIFM O8H202
MPN: O8H202 · IFM
Price on request
Request a quote