IFM PV7003
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Two switching outputs |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PV7003 be shipped?
PV7003 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PV7003 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PV7003 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PV7003, subject to availability and destination.
Compact housing for use where space is restricted Very high overpressure and vacuum resistance Robust stainless steel housing with high shock and vibration resistance Lifespan of more than 60 million pressure cycles Two programmable switching outputs, one of them with IO-Link communication interface User-friendly communication and parameterisation via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2 |
| Measuring range | -1...25 bar; -14.6...362.6 psi; -0.1...2.5 MPa |
| -1...25 bar | -14.6...362.6 psi |
| Process connection | threaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5 |
Application
| Measuring element | metallic thin film cell |
| Application | for industrial applications |
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -40...90 |
| Min. burst pressure | 600 bar; 8700 psi; 60 MPa |
| 600 bar | 8700 psi |
| Pressure rating | 65 bar; 940 psi; 6.5 MPa |
| 65 bar | 940 psi |
| Note on pressure rating | static |
| Vacuum resistance | -1000 mbar; -0.1 MPa |
| -1000 mbar | -0.1 MPa |
| Type of pressure | relative pressure; vacuum |
Electrical data
| Operating voltage[V] [V] | 18...30 DC |
| Current consumption[mA] [mA] | < 15 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 0.3 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | < 170 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | -1...25 bar; -14.6...362.6 psi; -0.1...2.5 MPa |
| -1...25 bar | -14.6...362.6 psi |
| Set point SP | -0.75...25 bar; -10.8...362.6 psi; -0.075...2.5 MPa |
| -0.75...25 bar | -10.8...362.6 psi |
| Reset point rP | -0.87...24.88 bar; -12.7...360.8 psi; -0.087...2488 MPa |
| -0.87...24.88 bar | -12.7...360.8 psi |
| In steps of | 0.01 bar; 0.1 psi; 0.001 MPa |
| 0.01 bar | 0.1 psi |
| Factory setting | SP1 = 6.25 bar; rP1 = 5.75 bar; ou1 = Hno;; SP2 = 18.75 bar; rP2 = 18.25 bar; ou2 = Hno;; dS1/dS2 = 0 ms; dr1/dr2 = 0 ms; coF = 0 %; P-n = PnP; dAP= 60 ms |
| SP1 = 6.25 bar | rP1 = 5.75 bar |
| SP2 = 18.75 bar | rP2 = 18.25 bar |
| dS1/dS2 = 0 ms | dr1/dr2 = 0 ms |
| coF = 0 % | P-n = PnP |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,5 (nach DIN EN 61298-2) |
| Repeatability[% of the span] [% of the span] | < ± 0,05; (with temperature fluctuations < 10 K) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,5; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1) |
| Linearity deviation[% of the span] [% of the span] | < ± 0,1 (BFSL) / < ± 0,2 (LS) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,2 |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (per 6 months) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C) |
Response times
| Response time[ms] [ms] | < 3 |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable; Function; Device diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 2 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 5 |
| Supported DeviceIDs | default; 712 |
| default | 712 |
Operating conditions
| Ambient temperature[°C] [°C] | -40...90 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 67; IP 69K |
Tests / approvals
| EMC | DIN EN 61326-1 |
| Shock resistance | DIN EN 60068-2-27; 500 g (1 ms) |
| DIN EN 60068-2-27 | 500 g (1 ms) |
| Vibration resistance | DIN EN 60068-2-6; 20 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 667.77 |
| UL approval | UL approval no.; J015 |
| UL approval no. | J015 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 63 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 19 / L = 66 |
| Materials | stainless steel (630/1.4542/17-4 PH); stainless steel (316L/1.4404); PEI |
| Materials (wetted parts) | stainless steel (303/1.4305); stainless steel (630/1.4542/17-4 PH) |
| Min. pressure cycles | 60 million; (at 1.2 times nominal pressure) |
| Tightening torque[Nm] [Nm] | 25...35; (recommended tightening torque; depends on the lubrication, the seal and the pressure load) |
| Process connection | threaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5 |
| Process connection sealing | FKM (DIN EN ISO 1179-2) |
| Restrictor element integrated | yes |
Remarks
| Remarks | BFSL = Best Fit Straight Line; LS = limit value setting |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A |









