IFM PT9552
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Transmitters small type PT / PU |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PT9552 be shipped?
PT9552 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PT9552 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PT9552 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PT9552, subject to availability and destination.
For the reliable detection of the system pressure in mobile machines High shock and vibration resistance Excellent repeatability and low linearity error Lifespan of more than 50 million pressure cycles Compact and robust stainless steel housing for use where space is restricted
Specifications
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 1 |
| Measuring range | 0...100 bar; 0...1450 psi; 0...10 MPa |
| 0...100 bar | 0...1450 psi |
| Process connection | threaded connection G 1/4 external thread |
Application
| Application | for mobile applications |
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -25...90; (on request: -40...100 °C) |
| Min. burst pressure | 1000 bar; 14500 psi; 100 MPa |
| 1000 bar | 14500 psi |
| Pressure rating | 200 bar; 2900 psi; 20 MPa |
| 200 bar | 2900 psi |
| Type of pressure | relative pressure |
Electrical data
| Operating voltage[V] [V] | 16...36 DC |
| Current consumption[mA] [mA] | < 6 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (80 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 1 |
| Output signal | analogue signal |
| Number of analogue outputs | 1 |
| Analogue voltage output[V] [V] | 0...10 |
| Min. load resistance[Ω] [Ω] | 2000 |
Measuring/setting range
| Measuring range | 0...100 bar; 0...1450 psi; 0...10 MPa |
| 0...100 bar | 0...1450 psi |
Accuracy / deviations
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation[% of the span] [% of the span] | < ± 1,0; (incl. drift when overtightened, zero point and span error) |
| Linearity deviation[% of the span] [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,2 |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (per 6 months) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,1; (-25...90 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,1; (-25...90 °C) |
Response times
| Step response time analogue output[ms] [ms] | 8 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...90 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 67; IP 69K |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; immunity; according to the automotive directive 1995/54/EC, 2004/104 EC, 2005/83/EC; ISO 11452-2; 100 V/m; ISO 11452-4; 100 mA / severity level 4; ISO 7637-2; severity level 4; radiation of interference; CISPR 25; EN 61000-6-1; EN 61000-6-4 |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| immunity | according to the automotive directive 1995/54/EC, 2004/104 EC, 2005/83/EC |
| ISO 11452-2 | 100 V/m |
| ISO 11452-4 | 100 mA / severity level 4 |
| ISO 7637-2 | severity level 4 |
| radiation of interference | CISPR 25 |
| Shock resistance | DIN IEC 68-2-27; 50 g (11 ms) |
| DIN IEC 68-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6; 20 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 1069 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 82.5 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 22 / L = 65.1 |
| Materials | stainless steel (316L/1.4404); PA |
| Materials (wetted parts) | stainless steel (316L/1.4404); FKM |
| Min. pressure cycles | 50 million |
| Process connection | threaded connection G 1/4 external thread |
| Restrictor element integrated | yes |
Remarks
| Remarks | BFSL = Best Fit Straight Line; LS = limit value setting |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A |



