IFM PT5002
Quick facts
| Availability | Confirmed on request |
| Category | Transmitters small type PT / PU |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PT5002 be shipped?
PT5002 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PT5002 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PT5002 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PT5002, subject to availability and destination.
Reliable detection of system pressure in industrial and mobile applications High shock and vibration resistance Excellent repeatability and low linearity error Lifespan of more than 60 million pressure cycles Compact and robust stainless steel housing for use where space is restricted
Specifications
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 1 |
| Measuring range | 0...100 bar; 0...1450 psi; 0...10 MPa |
| 0...100 bar | 0...1450 psi |
| Process connection | threaded connection G 1/4 external thread (DIN EN ISO 1179-2) |
Application
| Measuring element | metallic thin film cell |
| Application | for mobile applications; for industrial applications |
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -40...125 |
| Min. burst pressure | 1000 bar; 14500 psi; 100 MPa |
| 1000 bar | 14500 psi |
| Pressure rating | 250 bar; 3625 psi; 25 MPa |
| 250 bar | 3625 psi |
| Note on pressure rating | static |
| Vacuum resistance | -1000 mbar; -0.1 MPa |
| -1000 mbar | -0.1 MPa |
| Type of pressure | relative pressure |
Electrical data
| Operating voltage[V] [V] | 8...36 DC |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 0.1 |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 1 |
| Output signal | analogue signal |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | (Ub - 8 V) / 21,5 mA ; @8V= 0 Ω ; @12V max. 200 Ω: @24V max. 750 Ω |
| Short-circuit proof | yes |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 0...100 bar; 0...1450 psi; 0...10 MPa |
| 0...100 bar | 0...1450 psi |
Accuracy / deviations
| Repeatability[% of the span] [% of the span] | < ± 0,05; (with temperature fluctuations < 10 K) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,5; (incl. drift when overtightened, zero point and span error, non-linearity, hysteresis) |
| Linearity deviation[% of the span] [% of the span] | < ± 0,1 (BFSL) / < ± 0,2 (LS) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,2 |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (per 6 months) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,1 (0...80 °C); < ± 0,2 (-40...0 °C / 80...125 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,1 (0...80 °C); < ± 0,2 (-40...0 °C / 80...125 °C) |
Response times
| Step response time analogue output[ms] [ms] | 2 |
Operating conditions
| Ambient temperature[°C] [°C] | -40...100 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 67 |
Tests / approvals
| EMC | Compliant with ECE R 10, rev. 5; (E1 compliant); DIN EN ISO 13766-1 : 2018; earthworks and construction machines; DIN EN ISO 14982 : 2009; agricultural and forestry machines; ISO 11452-2; 100 V/m; ISO 7637-2 : 2011 pulse 1; Test severity III. function state C; ISO 7637-2 : 2011 pulse 2b; test severity IV. function state C; DIN EN 61326-1 |
| Compliant with ECE R 10, rev. 5 | (E1 compliant) |
| DIN EN ISO 13766-1 : 2018 | earthworks and construction machines |
| DIN EN ISO 14982 : 2009 | agricultural and forestry machines |
| ISO 11452-2 | 100 V/m |
| ISO 7637-2 : 2011 pulse 1 | Test severity III. function state C |
| ISO 7637-2 : 2011 pulse 2b | test severity IV. function state C |
| Shock resistance | DIN EN 60068-2-27; 500 g (1 ms) |
| DIN EN 60068-2-27 | 500 g (1 ms) |
| Vibration resistance | DIN EN 60068-2-6; 20 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 715 |
| UL approval | UL approval no.; J032; File number UL; E174189 |
| UL approval no. | J032 |
| File number UL | E174189 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 67.5 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 19 / L = 71 |
| Materials | stainless steel (630/1.4542/17-4 PH); stainless steel (316L/1.4404); PPS |
| Materials (wetted parts) | stainless steel (630/1.4542/17-4 PH); stainless steel (303/1.4305) |
| Min. pressure cycles | 60 million; (at 1.2 times nominal pressure) |
| Tightening torque[Nm] [Nm] | 25...35; (recommended tightening torque; depends on the lubrication, the seal and the pressure load) |
| Process connection | threaded connection G 1/4 external thread (DIN EN ISO 1179-2) |
| Process connection sealing | FKM (DIN EN ISO 1179-2) |
| Restrictor element integrated | yes |
Remarks
| Remarks | BFSL = Best Fit Straight Line; LS = limit value setting |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x valve plug type A DIN (EN175301-803-A) |