IFM PS3607
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Submersible pressure transmitters |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PS3607 be shipped?
PS3607 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PS3607 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PS3607 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PS3607, subject to availability and destination.
Low-cost, simple level measurement Pressure compensation via internally vented cable Reduced wiring complexity when operated as two-wire current loop High overall accuracy and long-term stability Robust stainless steel housing with high ingress resistance
Specifications
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 1 |
| Measuring range | 0...0.6 bar; 0...600 mbar; 0...8.7 psi; 0...240.9 inH2O; 0...60 kPa |
| 0...0.6 bar | 0...600 mbar |
Application
| Design | with capillary tube for pressure compensation |
| Application | for industrial applications |
| Media | Liquids |
| Medium temperature[°C] [°C] | -10...50 |
| Min. burst pressure | 4.8 bar; 70 psi; 480 kPa |
| 4.8 bar | 70 psi |
| Pressure rating | 4 bar; 58 psi; 400 kPa |
| 4 bar | 58 psi |
| Type of pressure | relative pressure |
Electrical data
| Operating voltage[V] [V] | 10...30 DC |
| Protection class | III |
| Reverse polarity protection | yes |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 1 |
| Output signal | analogue signal |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | 700; (Ub = 24 V; (Ub - 10 V) / 20 mA) |
| Short-circuit protection | yes |
Measuring/setting range
| Measuring range | 0...0.6 bar; 0...600 mbar; 0...8.7 psi; 0...240.9 inH2O; 0...60 kPa |
| 0...0.6 bar | 0...600 mbar |
Accuracy / deviations
| Repeatability[% of the span] [% of the span] | < 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation[% of the span] [% of the span] | < 0,5 (BFSL) / 1; (incl. linearity, zero and span error (limit value setting)) |
| Linearity deviation[% of the span] [% of the span] | < 0,2 (BFSL) |
| Long-term stability[% of the span] [% of the span] | < 0,2; (per year) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (0...50 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (0...50 °C) |
Operating conditions
| Ambient temperature[°C] [°C] | -10...50 |
| Storage temperature[°C] [°C] | -30...80 |
| Protection | IP 68 |
Tests / approvals
| MTTF[years] [years] | 403 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 2351.65 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 27 / L = 100 |
| Materials | stainless steel (316Ti/1.4571); PA |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Cable | 30 m, PUR, Ø 7.5 mm; Core insulation: |