IFM PN3093
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Type PN / PE with digital display |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PN3093 be shipped?
PN3093 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PN3093 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PN3093 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PN3093, subject to availability and destination.
Red/green display for clear identification of the acceptable range The process connection can be rotated for optimum alignment With long-term stability thanks to high overload protection Robust design for use in harsh industrial environments Convenient operation via buttons or parameter setting via IO-Link Programmable switching output with IO-Link and analogue output
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range | 0...25 bar; 0...362 psi; 0...2.5 MPa |
| 0...25 bar | 0...362 psi |
| Process connection | threaded connection G 1/4 internal thread M6 I |
Application
| Special feature | Gold-plated contacts |
| Measuring element | ceramic-capacitive pressure measuring cell |
| Application | for industrial applications |
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -25...80 |
| Min. burst pressure | 350 bar; 5075 psi; 35 MPa |
| 350 bar | 5075 psi |
| Pressure rating | 150 bar; 2175 psi; 15 MPa |
| 150 bar | 2175 psi |
| Vacuum resistance | -1000 mbar; -0.1 MPa |
| -1000 mbar | -0.1 MPa |
| Type of pressure | relative pressure |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | < 35 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 0.3 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design | PNP |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 150; (200 (...60 °C) 250 (...40 °C)) |
| Switching frequency DC[Hz] [Hz] | < 170 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | 500 |
| Analogue voltage output[V] [V] | 0...10 |
| Min. load resistance[Ω] [Ω] | 2000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 0...25 bar; 0...362 psi; 0...2.5 MPa |
| 0...25 bar | 0...362 psi |
| Set point SP | 0.2...25 bar; 3...363 psi; 0.02...2.5 MPa |
| 0.2...25 bar | 3...363 psi |
| Reset point rP | 0.1...24.9 bar; 1...361 psi; 0.01...2.49 MPa |
| 0.1...24.9 bar | 1...361 psi |
| Min. difference between SP and rP | 0.2 bar; 2 psi; 0.02 MPa |
| 0.2 bar | 2 psi |
| In steps of | 0.1 bar; 1 psi; 0.01 MPa |
| 0.1 bar | 1 psi |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,5 |
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,25 |
| Long-term stability[% of the span] [% of the span] | < ± 0,05; (per 6 months) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (-0...80 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (-0...80 °C) |
Response times
| Response time[ms] [ms] | < 3 |
| Delay time programmable dS, dr[s] [s] | 0...50 |
| Damping process value dAP[s] [s] | 0...4 |
| Damping for the analogue output dAA[s] [s] | 0...4 |
| Max. response time analogue output[ms] [ms] | 3 |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 1 |
| Supported DeviceIDs | Factory setting / CMPT = 2; 430; Status_B High Resolution / CMPT = 3; 609 |
| Factory setting / CMPT = 2 | 430 |
| Status_B High Resolution / CMPT = 3 | 609 |
| Note | For further information please see the IODD PDF file under "Downloads" |
| Profiles | Smart Sensor - SSP 3.1; Measuring Sensor; Common - I&D; Identification and Diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| Min. process cycle time[ms] [ms] | 3 |
| IO-Link resolution pressure | 0.01 bar; 0.001 MPa |
| 0.1 bar | 0.01 MPa |
| IO-Link process data (cyclical) | pressure; 16; device status; 4; binary switching information; 1 |
| pressure | 16 |
| binary switching information | 1 |
| IO-Link functions (acyclical) | application specific tag |
| Smart Sensor - SSP 3.1 | Measuring Sensor |
| Common - I&D | Identification and Diagnosis |
| 0.01 bar | 0.001 MPa |
| device status | 4 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...80 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27; 50 g (11 ms) |
| DIN EN 60068-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 20 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 226 |
| UL approval | UL approval no.; J004 |
| UL approval no. | J004 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 235 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 34 / L = 90.7 |
| Materials | stainless steel (316L/1.4404) stainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC |
| Materials (wetted parts) | stainless steel (316L/1.4404); Al2O3 (ceramics); FKM |
| Min. pressure cycles | 100 million |
| Tightening torque[Nm] [Nm] | 25...35; (recommended tightening torque; depends on the lubrication, the seal and the pressure load) |
| Process connection | threaded connection G 1/4 internal thread M6 I |
| Restrictor element integrated | no (can be retrofitted) |
Displays / operating elements
| Display | Display unit; 3 x LED, green (bar, psi, MPa); switching status; 1 x LED, yellow; measured values; alphanumeric display, red/green 4-digit |
| Display unit | 3 x LED, green (bar, psi, MPa) |
| switching status | 1 x LED, yellow |
| measured values | alphanumeric display, red/green 4-digit |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |