Quick facts
| Availability | Confirmed on request |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PM2053 be shipped?
PM2053 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PM2053 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PM2053 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PM2053, subject to availability and destination.
For the reliable hydrostatic level detection Flush mount installation in the tank or container wall Robust potted stainless steel housing as protection against aggressive media and ingress of moisture Scalable analogue output with adjustable span and zero point Can be connected as two-wire or three-wire
Specifications
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 1 |
| Measuring range | -1...25 bar; -15...363 psi; -0.1...2.5 MPa |
| -1...25 bar | -15...363 psi |
| Process connection | threaded connection Aseptoflex external thread Aseptoflex |
Application
| Special feature | Gold-plated contacts |
| Application | flush mountable for the food and beverage industry |
| Media | viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature[°C] [°C] | -25...125; (145 max. 1h) |
| Min. burst pressure | 350 bar; 5070 psi; 35 MPa |
| 350 bar | 5070 psi |
| Pressure rating | 100 bar; 1450 psi; 10 MPa |
| 100 bar | 1450 psi |
| Type of pressure | relative pressure |
| No dead space | yes |
Electrical data
| Operating voltage[V] [V] | 14...30 DC |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 1 |
| Output signal | analogue signal |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | 550; (Ub = 24 V; (Ub - 13 V) / 20 mA) |
| Overload protection | yes |
Measuring/setting range
| Measuring range | -1...25 bar; -15...363 psi; -0.1...2.5 MPa |
| -1...25 bar | -15...363 psi |
| Analogue start point | -1...18.8 bar; -15...272 psi; -0.1...1.88 MPa |
| -1...18.8 bar | -15...272 psi |
| Analogue end point | 5.3...25 bar; 76...363 psi; 0.53...2.5 MPa |
| 5.3...25 bar | 76...363 psi |
| In steps of | 0.1 bar; 1 psi; 0.01 MPa |
| 0.1 bar | 1 psi |
| Factory setting | ASP = 0.0 bar; AEP = 25.0 bar |
Accuracy / deviations
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,6; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
| Linearity deviation[% of the span] [% of the span] | < ± 0,5; (Turn down 1:1) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,1; (Turn down 1:1) |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,1; (0...80 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (0...80 °C) |
Response times
| Max. response time analogue output[ms] [ms] | 3 |
Software / programming
| Parameter setting options | zero point; span |
Interfaces
| Communication interface | EPS |
Operating conditions
| Ambient temperature[°C] [°C] | -25...80 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 67 |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 1 GHz / accuracy < 2,5%; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 1 GHz / accuracy < 2,5% |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| Shock resistance | DIN IEC 68-2-27; 50 g (11 ms) |
| DIN IEC 68-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6; 20 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 271 |
Mechanical data
| Weight[g] [g] | 474 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 34 / L = 121.5 |
| Materials | stainless steel (316L/1.4404); PEI; FKM |
| Materials (wetted parts) | ceramics (99.9 % Al2O3); stainless steel (316L/1.4404) surface characteristics: Ra < 0,4 µm / Rz = 4 µm; PTFE |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection Aseptoflex external thread Aseptoflex |
Remarks
| Remarks | The 3-A qualification is only valid if adapters with 3-A qualification are used for installation. |
| Notes | Please do not use for new projects.; no more adapters available as accessories |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |