IFM PI2995
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PI2995 be shipped?
PI2995 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PI2995 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PI2995 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PI2995, subject to availability and destination.
Combined level measurement and point level detection with analogue / switching output Resistant to high-pressure cleaning with aggressive cleaning agents For use in high temperatures in process technology Hygienic design for the requirements of the food and beverage industry Flush mount installation in containers, tanks and pipes
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range | -1...4 bar; -14.5...58 psi; -100...400 kPa |
| -1...4 bar | -14.5...58 psi |
| Process connection | threaded connection G 3/4 external thread |
Application
| Special feature | Gold-plated contacts |
| Application | flush mountable for the food and beverage industry |
| Installation | freely rotatable housing 350° |
| Media | viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature[°C] [°C] | -25...125; (145 max. 1h) |
| Min. burst pressure | 100 bar; 1450 psi; 10000 kPa |
| 100 bar | 1450 psi |
| Pressure rating | 30 bar; 435 psi; 3000 kPa |
| 30 bar | 435 psi |
| Type of pressure | relative pressure; vacuum |
| No dead space | yes |
Electrical data
| Operating voltage[V] [V] | 18...32 DC |
| Current consumption[mA] [mA] | < 50 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 0.5 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250 |
| Switching frequency DC[Hz] [Hz] | 6 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20, invertible; (scalable 1:4) |
| Max. load[Ω] [Ω] | (Ub - 10 V) / 20 mA |
| Analogue voltage output[V] [V] | 0...10, invertible; (scalable 1:4) |
| Min. load resistance[Ω] [Ω] | 2000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | -1...4 bar; -14.5...58 psi; -100...400 kPa |
| -1...4 bar | -14.5...58 psi |
| Set point SP | -0.99...4 bar; -14.35...58 psi; -99...400 kPa |
| -0.99...4 bar | -14.35...58 psi |
| Reset point rP | -1...3.99 bar; -14.5...57.85 psi; -100...399 kPa |
| -1...3.99 bar | -14.5...57.85 psi |
| Analogue start point | -1...3 bar; -14.5...43.5 psi; -100...300 kPa |
| -1...3 bar | -14.5...43.5 psi |
| Analogue end point | 0...4 bar; 0...58 psi; 0...400 kPa |
| 0...4 bar | 0...58 psi |
| In steps of | 0.005 bar; 0.05 psi; 0.5 kPa |
| 0.005 bar | 0.05 psi |
| Factory setting | SP1 = 1.000 bar; rP1 = 0.920 bar; ASP = 0.000 bar; AEP = 4.000 bar |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,2; (Turn down 1:1) |
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
| Linearity deviation[% of the span] [% of the span] | < ± 0,15; (Turn down 1:1) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,15; (Turn down 1:1) |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,05; (0...70 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,15; (0...70 °C) |
Response times
| Response time[ms] [ms] | < 100 |
| Damping process value dAP[s] [s] | 0.1...100 |
| Damping for the analogue output dAA[s] [s] | 0.1...100 |
| Step response time analogue output[ms] [ms] | 25 |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span |
Operating conditions
| Ambient temperature[°C] [°C] | -25...80 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 67; IP 69K |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-5 Surge; 0,5/1 kV; EN 61000-4-6 HF conducted; 10 V |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-5 Surge | 0,5/1 kV |
| EN 61000-4-6 HF conducted | 10 V |
| Shock resistance | DIN IEC 68-2-27; 50 g (11 ms) |
| DIN IEC 68-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6; 20 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 163 |
Mechanical data
| Weight[g] [g] | 384 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 34 / L = 119 |
| Materials | stainless steel (316L/1.4404); PC; PBT; PEI; FKM; PTFE |
| Materials (wetted parts) | ceramics (99.9 % Al2O3); stainless steel (316L/1.4435) surface characteristics: Ra < 0,4 µm / Rz = 4 µm; PTFE |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection G 3/4 external thread |
Displays / operating elements
| Display | Display unit; 4 x LED, green; switching status; LED, yellow; function display; alphanumeric display, 4-digit; measured values; alphanumeric display, 4-digit |
| Display unit | bar; psi; kPa; % of the span |
| switching status | LED, yellow |
| function display | alphanumeric display, 4-digit |
| measured values | alphanumeric display, 4-digit |
Remarks
| Notes | phase-out article |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |