IFM PI2306
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Use in process technology at high temperatures |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PI2306 be shipped?
PI2306 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PI2306 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PI2306 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PI2306, subject to availability and destination.
For use in high temperatures in the food and beverage industry Robust stainless steel housing with hygienic front-flush design With two-wire and three-wire connection technology Reduced wiring complexity when operated as two-wire current loop Integrated clamp diaphragm seal with stainless steel membrane Convenient operation via buttons or parameter setting via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range | -0.124...2.5 bar; -1.8...36.27 psi; -12.4...250 kPa |
| -0.124...2.5 bar | -1.8...36.27 psi |
| Process connection | Clamp DN50 (2") DIN 32676 (ISO 2852) |
Application
| Special feature | Gold-plated contacts |
| Application | flush mountable for the food and beverage industry |
| Media | viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature[°C] [°C] | -20...200; (-20...90 < 0 bar) |
| Min. burst pressure | 50 bar; 725 psi; 5000 kPa |
| 50 bar | 725 psi |
| Pressure rating | 20 bar; 290 psi; 2000 kPa |
| 20 bar | 290 psi |
| Type of pressure | relative pressure |
Electrical data
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Integrated watchdog | yes |
| Operating voltage[V] [V] | 18...32 DC |
| Current consumption[mA] [mA] | < 45 |
| Power-on delay time[s] [s] | 0.5 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20, invertible; (scalable) |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Max. load[Ω] [Ω] | (Ub - 10 V) / 20 mA |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250 |
| Switching frequency DC[Hz] [Hz] | 125 |
Measuring/setting range
| Measuring range | -0.124...2.5 bar; -1.8...36.27 psi; -12.4...250 kPa |
| -0.124...2.5 bar | -1.8...36.27 psi |
| Set point SP | -0.12...2.5 bar; -1.74...36.27 psi; -12...250 kPa |
| -0.12...2.5 bar | -1.74...36.27 psi |
| Reset point rP | -0.124...2.496 bar; -1.8...36.21 psi; -12.4...249.6 kPa |
| -0.124...2.496 bar | -1.8...36.21 psi |
| Analogue start point | -0.124...1.88 bar; -1.8...27.27 psi; -12.4...188 kPa |
| -0.124...1.88 bar | -1.8...27.27 psi |
| Analogue end point | 0.5...2.5 bar; 7.26...36.27 psi; 50...250 kPa |
| 0.5...2.5 bar | 7.26...36.27 psi |
| In steps of | 0.002 bar; 0.03 psi; 0.2 kPa |
| 0.002 bar | 0.03 psi |
| Factory setting | SP1 = 0.624 bar; rP1 = 0.574 bar; SP2 = 1.874 bar; rP2 = 1.824 bar; ASP = 0.000 bar; AEP = 2.500 bar |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,2; (Turn down 1:1) |
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
| Linearity deviation[% of the span] [% of the span] | < ± 0,15; (Turn down 1:1) |
| Zero-point stabilisation[% of the span] [% of the span] | IO-Link, analogue output; 0,15; display, switching output; 0,2 |
| IO-Link, analogue output | 0,15 |
| display, switching output | 0,2 |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,15; (Turn down 1:1) |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (0...200 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,15; (0...200 °C) |
Response times
| Damping process value dAP[s] [s] | 0...30 |
| Damping for the analogue output dAA[s] [s] | 0.01...99.99 |
| Step response time analogue output[ms] [ms] | 7 |
| Min. response time of switching output (dAP)[ms] [ms] | 3 |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.0 |
| SDCI standard | IO-Link Communication Specification, Version 1.0, January 2009, Ordner No: 10.002 |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 2.3 |
| Supported DeviceIDs | default; 159 |
| default | 159 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...65 |
| Note on ambient temperature | Medium temperature: ≤ 200 °C |
| Storage temperature[°C] [°C] | -25...100 |
| Protection | IP 67; IP 68; IP 69K |
Tests / approvals
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27; 50 g (11 ms) |
| DIN EN 60068-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 20 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 142 |
| Note on approval | Including free 6-point calibration certificate. |
Mechanical data
| Weight[g] [g] | 1194.7 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 50 / L = 163 |
| Materials | stainless steel (316L/1.4404); stainless steel (316L/1.4435); PBT; PEI; PFA |
| Materials (wetted parts) | stainless steel (316L/1.4435) |
| Min. pressure cycles | 10 million |
| Process connection | Clamp DN50 (2") DIN 32676 (ISO 2852) |
| Surface characteristics Ra/Rz of the wetted parts | Ra < 0.38 µm |
| Fill fluid for pressure transmission | NEOBEE (food grade, FDA compliant) |
| Diaphragm diameter[mm] [mm] | 47.5 |
Displays / operating elements
| Display | Display unit; LED, green; switching status; LED, yellow; function display; alphanumeric display, 4-digit; measured values; alphanumeric display, 4-digit |
| Display unit | bar; kPa; psi; inH2O; mWS; % of the span |
| switching status | LED, yellow |
| function display | alphanumeric display, 4-digit |
| measured values | alphanumeric display, 4-digit |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |