IFM PI1094
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PI1094 be shipped?
PI1094 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PI1094 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PI1094 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PI1094, subject to availability and destination.
Combined level measurement and point level detection with analogue / switching output Resistant to high-pressure cleaning with aggressive cleaning agents For use in high temperatures in process technology Hygienic design for the requirements of the food and beverage industry Flush mount installation in containers, tanks and pipes
Specifications
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 1 |
| Measuring range | -1...10 bar; -14.5...145 psi; -100...1000 kPa; -0.1...1 MPa |
| -1...10 bar | -14.5...145 psi |
| Process connection | threaded connection Aseptoflex external thread Aseptoflex |
Application
| Special feature | Gold-plated contacts |
| Application | flush mountable for the food and beverage industry |
| Installation | freely rotatable housing 350° |
| Media | viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature[°C] [°C] | -25...125; (145 max. 1h) |
| Min. burst pressure | 150 bar; 2175 psi; 15 MPa |
| 150 bar | 2175 psi |
| Pressure rating | 50 bar; 725 psi; 5 MPa |
| 50 bar | 725 psi |
| Type of pressure | relative pressure |
| No dead space | yes |
Electrical data
| Operating voltage[V] [V] | 20...32 DC |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 0.5 |
| Switch-on peak current[mA] [mA] | 6 |
| Switch-on peak current duration[ms] [ms] | 30 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 1 |
| Output signal | analogue signal |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20, invertible; (scalable 1:4) |
| Max. load[Ω] [Ω] | 300 |
| Overload protection | yes |
Measuring/setting range
| Measuring range | -1...10 bar; -14.5...145 psi; -100...1000 kPa; -0.1...1 MPa |
| -1...10 bar | -14.5...145 psi |
| Analogue start point | -1...7.25 bar; -14.5...105.1 psi; -0.1...0.725 MPa |
| -1...7.25 bar | -14.5...105.1 psi |
| Analogue end point | 1.75...10 bar; 25.4...145 psi; 0.175...1 MPa |
| 1.75...10 bar | 25.4...145 psi |
| In steps of | 0.01 bar; 0.1 psi; 0.001 MPa |
| 0.01 bar | 0.1 psi |
| Factory setting | ASP = 0.00 bar; AEP = 10.00 bar |
Accuracy / deviations
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
| Linearity deviation[% of the span] [% of the span] | < ± 0,15; (Turn down 1:1) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,15; (Turn down 1:1) |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,05; (0...70 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,15; (0...70 °C) |
Response times
| Damping for the analogue output dAA[s] [s] | 0.1...100 |
| Max. response time analogue output[ms] [ms] | 40 |
Software / programming
| Parameter setting options | zero point; span |
Operating conditions
| Ambient temperature[°C] [°C] | -25...80 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 67; IP 69K |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-5 Surge; 0,5/1 kV; EN 61000-4-6 HF conducted; 10 V |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-5 Surge | 0,5/1 kV |
| EN 61000-4-6 HF conducted | 10 V |
| Shock resistance | DIN IEC 68-2-27; 50 g (11 ms) |
| DIN IEC 68-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6; 20 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 238 |
Mechanical data
| Weight[g] [g] | 403.5 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 34 / L = 119 |
| Materials | stainless steel (316L/1.4404); PC; PBT; PEI; FKM; PTFE |
| Materials (wetted parts) | ceramics (99.9 % Al2O3); stainless steel (316L/1.4435) surface characteristics: Ra < 0,4 µm / Rz = 4 µm; PTFE |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection Aseptoflex external thread Aseptoflex |
Displays / operating elements
| Display | Display unit; 4 x LED, green; function display; alphanumeric display, 4-digit; measured values; alphanumeric display, 4-digit |
| Display unit | bar; psi; MPa; % of the span |
| function display | alphanumeric display, 4-digit |
| measured values | alphanumeric display, 4-digit |
Remarks
| Remarks | The 3-A qualification is only valid if adapters with 3-A qualification are used for installation. |
| Notes | Please do not use for new projects.; no more adapters available as accessories |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |