IFM PI009A
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Use in hazardous areas |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PI009A be shipped?
PI009A is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PI009A in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PI009A and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PI009A, subject to availability and destination.
For applications in hazardous areas With switching output and analogue output Scalable analogue output with adjustable span and zero point Resistant to high-pressure cleaning with aggressive cleaning agents Clearly visible 4-digit LED display
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range | -1...1 bar; -1000...1000 mbar; -14.5...14.5 psi; -100...100 kPa |
| -1...1 bar | -1000...1000 mbar |
| Process connection | threaded connection G 1 external thread sealing cone |
Application
| Special feature | Gold-plated contacts |
| Application | food and beverage industry |
| Installation | freely rotatable housing 350° |
| Media | viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature[°C] [°C] | -20...60; (when used outside the hazardous area:; Ambient temperature: -25...85 °C; Medium temperature: -25...125 °C / 145 °C < 1h) |
| Min. burst pressure | 30000 mbar; 435 psi; 3000 kPa |
| 30000 mbar | 435 psi |
| Pressure rating | 10000 mbar; 145 psi; 1000 kPa |
| 10000 mbar | 145 psi |
| Type of pressure | relative pressure; vacuum |
Electrical data
| Operating voltage[V] [V] | 18...32 DC |
| Current consumption[mA] [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 0.5 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250 |
| Switching frequency DC[Hz] [Hz] | 6 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20, invertible; (scalable 1:4) |
| Max. load[Ω] [Ω] | (Ub - 10 V) / 20 mA |
| Analogue voltage output[V] [V] | 0...10, invertible; (scalable 1:4) |
| Min. load resistance[Ω] [Ω] | 2000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | -1...1 bar; -1000...1000 mbar; -14.5...14.5 psi; -100...100 kPa |
| -1...1 bar | -1000...1000 mbar |
| Set point SP | -998...1000 mbar; -14.45...14.5 psi; -99.8...100 kPa |
| -998...1000 mbar | -14.45...14.5 psi |
| Reset point rP | -1000...998 mbar; -14.5...14.45 psi; -100...99.8 kPa |
| -1000...998 mbar | -14.5...14.45 psi |
| Analogue start point | -1000...500 mbar; -14.5...7.25 psi; -100...50 kPa |
| -1000...500 mbar | -14.5...7.25 psi |
| Analogue end point | -500...1000 mbar; -7.25...14.5 psi; -50...100 kPa |
| -500...1000 mbar | -7.25...14.5 psi |
| In steps of | 1 mbar; 0.05 psi; 0.1 kPa |
| 1 mbar | 0.05 psi |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,2; (Turn down 1:1) |
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
| Linearity deviation[% of the span] [% of the span] | < ± 0,15; (Turn down 1:1) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,15; (Turn down 1:1) |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,05; (0...70 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,15; (0...70 °C) |
Response times
| Response time[ms] [ms] | < 100 |
| Damping process value dAP[s] [s] | 0.1...100 |
| Damping for the analogue output dAA[s] [s] | 0.1...100 |
| Step response time analogue output[ms] [ms] | 25 |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span |
Operating conditions
| Ambient temperature[°C] [°C] | -20...60 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 65 |
Tests / approvals
| ATEX marking | II 3D Ex tc IIIC T90°C Dc X |
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-5 Surge; 0,5/1 kV; EN 61000-4-6 HF conducted; 10 V |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-5 Surge | 0,5/1 kV |
| EN 61000-4-6 HF conducted | 10 V |
| Shock resistance | DIN IEC 68-2-27; 50 g (11 ms) |
| DIN IEC 68-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6; 20 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 163 |
Mechanical data
| Weight[g] [g] | 513 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 36 / L = 132 |
| Materials | stainless steel (316L/1.4404); PC; PBT; PEI; FKM; PTFE |
| Materials (wetted parts) | ceramics (99.9 % Al2O3); stainless steel (316L/1.4435); stainless steel (316L/1.4404) surface characteristics: Ra < 0,4 µm / Rz = 4 µm; PTFE; EPDM |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection G 1 external thread sealing cone |
Displays / operating elements
| Display | Display unit; 6 x, green; switching status; LED, yellow; function display; alphanumeric display, 4-digit; measured values; alphanumeric display, 4-digit |
| Display unit | mbar; kPa; psi; inH2O; mWS; % of the span |
| switching status | LED, yellow |
| function display | alphanumeric display, 4-digit |
| measured values | alphanumeric display, 4-digit |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |



