Available on request

IFM PI008A

MPN: PI008A · Brand: IFM
Price on request
12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryUse in hazardous areas
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can PI008A be shipped?

PI008A is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up PI008A in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for PI008A and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PI008A, subject to availability and destination.

For applications in hazardous areas With switching output and analogue output Scalable analogue output with adjustable span and zero point Resistant to high-pressure cleaning with aggressive cleaning agents Clearly visible 4-digit LED display

Specifications

Product characteristics

Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1
Measuring range-0.0124...0.25 bar; -12.4...250 mbar; -5...100.4 inH2O; -1.24...25 kPa
-0.0124...0.25 bar-12.4...250 mbar
Process connectionthreaded connection G 1 external thread sealing cone

Application

Special featureGold-plated contacts
Applicationfood and beverage industry
Installationfreely rotatable housing 350°
Mediaviscous media and liquids with suspended particles; liquids and gases
Medium temperature[°C] [°C]-20...60; (when used outside the hazardous area:; Ambient temperature: -25...85 °C; Medium temperature: -25...125 °C / 145 °C < 1h)
Min. burst pressure30000 mbar; 12044 inH2O; 3000 kPa
30000 mbar12044 inH2O
Pressure rating6000 mbar; 2400 inH2O; 600 kPa
6000 mbar2400 inH2O
Type of pressurerelative pressure; vacuum

Electrical data

Operating voltage[V] [V]18...32 DC
Current consumption[mA] [mA]< 50
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]0.5
Integrated watchdogyes

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; (configurable)
Electrical designPNP/NPN
Number of digital outputs1
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250
Switching frequency DC[Hz] [Hz]6
Number of analogue outputs1
Analogue current output[mA] [mA]4...20, invertible; (scalable 1:4)
Max. load[Ω] [Ω](Ub - 10 V) / 20 mA
Analogue voltage output[V] [V]0...10, invertible; (scalable 1:4)
Min. load resistance[Ω] [Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range-0.0124...0.25 bar; -12.4...250 mbar; -5...100.4 inH2O; -1.24...25 kPa
-0.0124...0.25 bar-12.4...250 mbar
Set point SP-12...250 mbar; -4.8...100.4 inH2O; -1.2...25 kPa
-12...250 mbar-4.8...100.4 inH2O
Reset point rP-12.4...249.6 mbar; -5...100.2 inH2O; -1.24...24.96 kPa
-12.4...249.6 mbar-5...100.2 inH2O
Analogue start point-12.4...187.4 mbar; -5...75.2 inH2O; -1.24...18.74 kPa
-12.4...187.4 mbar-5...75.2 inH2O
Analogue end point50...250 mbar; 20.1...100.4 inH2O; 5...25 kPa
50...250 mbar20.1...100.4 inH2O
In steps of0.2 mbar; 0.1 inH2O; 0.02 kPa
0.2 mbar0.1 inH2O

Accuracy / deviations

Switch point accuracy[% of the span] [% of the span]< ± 0,2; (Turn down 1:1)
Repeatability[% of the span] [% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation[% of the span] [% of the span]< ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1)
Linearity deviation[% of the span] [% of the span]< ± 0,15; (Turn down 1:1)
Hysteresis deviation[% of the span] [% of the span]< ± 0,15; (Turn down 1:1)
Long-term stability[% of the span] [% of the span]< ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]< ± 0,05; (0...70 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]< ± 0,15; (0...70 °C)

Response times

Response time[ms] [ms]< 100
Damping process value dAP[s] [s]0.1...100
Damping for the analogue output dAA[s] [s]0.1...100
Step response time analogue output[ms] [ms]25

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span

Operating conditions

Ambient temperature[°C] [°C]-20...60
Storage temperature[°C] [°C]-40...100
ProtectionIP 65

Tests / approvals

ATEX markingII 3D Ex tc IIIC T90°C Dc X
EMCEN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-5 Surge; 0,5/1 kV; EN 61000-4-6 HF conducted; 10 V
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated10 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-5 Surge0,5/1 kV
EN 61000-4-6 HF conducted10 V
Shock resistanceDIN IEC 68-2-27; 50 g (11 ms)
DIN IEC 68-2-2750 g (11 ms)
Vibration resistanceDIN IEC 68-2-6; 20 g (10...2000 Hz)
DIN IEC 68-2-620 g (10...2000 Hz)
MTTF[years] [years]163

Mechanical data

Weight[g] [g]509
Housingcylindrical
Dimensions[mm] [mm]Ø 36 / L = 132
Materialsstainless steel (316L/1.4404); PC; PBT; PEI; FKM; PTFE
Materials (wetted parts)ceramics (99.9 % Al2O3); stainless steel (316L/1.4435); stainless steel (316L/1.4404) surface characteristics: Ra < 0,4 µm / Rz = 4 µm; PTFE; EPDM
Min. pressure cycles100 million
Process connectionthreaded connection G 1 external thread sealing cone

Displays / operating elements

DisplayDisplay unit; 6 x, green; switching status; LED, yellow; function display; alphanumeric display, 4-digit; measured values; alphanumeric display, 4-digit
Display unitmbar; kPa; inH2O; mmWS; % of the span
switching statusLED, yellow
function displayalphanumeric display, 4-digit
measured valuesalphanumeric display, 4-digit

Remarks

Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More IFM parts

IFM O8H205Available on requestIFM O8H205
MPN: O8H205 · IFM
Price on request
Request a quote
IFM O8H206Available on requestIFM O8H206
MPN: O8H206 · IFM
Price on request
Request a quote
IFM O8H207Available on requestIFM O8H207
MPN: O8H207 · IFM
Price on request
Request a quote
IFM O8H202Available on requestIFM O8H202
MPN: O8H202 · IFM
Price on request
Request a quote