IFM PG2451
Quick facts
| Availability | Confirmed on request |
| Category | Electronic contact manometers with analogue display |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PG2451 be shipped?
PG2451 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PG2451 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PG2451 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PG2451, subject to availability and destination.
Analogue display, pressure switch and transmitter in one unit Excellent readability also over a long distance Rotatable display with LED bar graph for switch point indication Programmable switching output and scalable analogue output Robust stainless steel housing for use in harsh industrial environments
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range | 0...250 bar; 0...3625 psi |
| 0...250 bar | 0...3625 psi |
| Process connection | threaded connection G 1/2 external thread |
Application
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Media | liquids and gases |
| Conditionally suitable for | use in gases at pressures > 25 bar only on request |
| Medium temperature[°C] [°C] | -25...80 |
| Min. burst pressure | 1000 bar; 14500 psi; 100 MPa |
| 1000 bar | 14500 psi |
| Pressure rating | 600 bar; 8700 psi; 60 MPa |
| 600 bar | 8700 psi |
| Type of pressure | relative pressure |
Electrical data
| Operating voltage[V] [V] | 18...32 DC |
| Current consumption[mA] [mA] | < 70; (24 V) |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 6 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250 |
| Switching frequency DC[Hz] [Hz] | 75 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20, invertible; (scalable) |
| Max. load[Ω] [Ω] | (Ub - 10 V) / 20 mA |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 0...250 bar; 0...3625 psi |
| 0...250 bar | 0...3625 psi |
| Set point SP | 1...400 bar; 15...5800 psi |
| 1...400 bar | 15...5800 psi |
| Reset point rP | 0...399 bar; 0...5785 psi |
| 0...399 bar | 0...5785 psi |
| Analogue start point | 0...350 bar; 0...5075 psi |
| 0...350 bar | 0...5075 psi |
| Analogue end point | 50...400 bar; 725...5800 psi |
| 50...400 bar | 725...5800 psi |
| In steps of | 0.5 bar; 5 psi |
| 0.5 bar | 5 psi |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,6; (Turn down 1:1) |
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,35 (BFSL) / < ± 0,6 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,5; (Turn down 1:1) |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (Turn down 1:1; per 6 months) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,3; (0...70 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,3; (0...70 °C) |
Response times
| Response time[ms] [ms] | < 9 |
| Damping process value dAP[s] [s] | 0.01...30 |
| Damping for the analogue output dAA[s] [s] | 0.01...30 |
| Step response time analogue output[ms] [ms] | 28 |
Operating conditions
| Ambient temperature[°C] [°C] | -20...80 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 67; IP 69K |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-5 Surge; 0,5/1 kV; EN 61000-4-6 HF conducted; 10 V |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-5 Surge | 0,5/1 kV |
| EN 61000-4-6 HF conducted | 10 V |
| Shock resistance | DIN EN 60068-2-27; 50 g (11 ms) |
| DIN EN 60068-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 10 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 10 g (10...2000 Hz) |
| MTTF[years] [years] | 100 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 563 |
| Dimensions[mm] [mm] | 169 x 100 x 57 |
| Materials | stainless steel (316L/1.4404); PA; FKM; PTFE; viewing glass: laminated safety glass 4 mm |
| Materials (wetted parts) | Al2O3 (ceramics); FKM; stainless steel (316L/1.4404) |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection G 1/2 external thread |
| Restrictor element integrated | yes |
Displays / operating elements
| Display | Display unit; 2 x LED, green; switching status; LED, yellow; switch points; LED ring, red; function display; alphanumeric display, red 4-digit; measured values; analogue display, 0...350° rotatable, pointer not visible when unit disconnected; measured values; alphanumeric display, red 4-digit |
| Display unit | 2 x LED, green |
| switching status | LED, yellow |
| switch points | LED ring, red |
| function display | alphanumeric display, red 4-digit |
| measured values | alphanumeric display, red 4-digit |
| With scale | yes |
| Extended display range (max.) | 400 bar; 5800 psi |
| 400 bar | 5800 psi |
Remarks
| Remarks | switch point accuracy in the extended display range: 1.5 % of the span |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |