Quick facts

AvailabilityConfirmed on request
CategoryElectronic contact manometers with analogue display
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can PG1401 be shipped?

PG1401 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up PG1401 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for PG1401 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PG1401, subject to availability and destination.

Manometer display, pressure switch and transmitter in one unit Excellent readability also over a long distance Rotatable display with LED indication for flexible visualisation Programmable switching output and scalable analogue output Robust stainless steel housing for use in harsh industrial environments Convenient operation via buttons or parameter setting via IO-Link

Specifications

Product characteristics

Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1
Measuring range0...250 bar; 0...3626 psi
0...250 bar0...3626 psi
Process connectionthreaded connection G 1/2 DIN EN 837-1

Application

Special featureGold-plated contacts
Applicationfor industrial applications
Medialiquids and gases
Medium temperature[°C] [°C]-25...80; (higher temperature upon request)
Min. burst pressure1000 bar; 14503 psi
1000 bar14503 psi
Pressure rating600 bar; 8702 psi
600 bar8702 psi
Vacuum resistance-1000 mbar; 14.5 psi
-1000 mbar14.5 psi
Type of pressurerelative pressure; vacuum

Electrical data

Operating voltage[V] [V]18...30 DC
Current consumption[mA] [mA]25...260
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]< 0.5
Integrated watchdogyes

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; IO-Link
Electrical designPNP/NPN
Number of digital outputs1
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]100
Switching frequency DC[Hz] [Hz]125
Number of analogue outputs1
Analogue current output[mA] [mA]4...20, invertible; (scalable)
Max. load[Ω] [Ω]500
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range0...250 bar; 0...3626 psi
0...250 bar0...3626 psi
Set point SP0...250 bar; 0...3626 psi
Analogue start point0...200 bar; 0...2901 psi
0...200 bar0...2901 psi
Analogue end point50...250 bar; 725...3626 psi
50...250 bar725...3626 psi
In steps of0.1 bar; 5 psi
0.1 bar5 psi
Factory settingSP1 = 906 psi; SP2 = 834 psi; ASP = 0.00 psi; AEP = 3626 psi; dAP = 0.06 s; dAA = 0.06 s

Accuracy / deviations

Switch point accuracy[% of the span] [% of the span]< ± 0,5; (DIN EN IEC 62828-1; Turn down 1:1)
Repeatability[% of the span] [% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation[% of the span] [% of the span]< ± 0,5; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1)
Zero-point stabilisation[% of the span] [% of the span]IO-Link, analogue output; 0,3; (see operating instructions zero-point behaviour); display, switching output; 0,6
IO-Link, analogue output0,3; (see operating instructions zero-point behaviour)
display, switching output0,6
Hysteresis deviation[% of the span] [% of the span]< ± 0,3; (Turn down 1:1 -25...80°C)
Long-term stability[% of the span] [% of the span]< ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]< ± 0,25; (0...70 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]< ± 0,25; (0...70 °C)

Response times

Min. response time of switching output (dAP)[ms] [ms]3
Damping process value dAP[s] [s]0...99.99
Damping for the analogue output dAA[s] [s]0...99.99
Step response time analogue output[ms] [ms]7

Interfaces

Communication interfaceIO-Link
Transmission typeCOM3 (230,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 4.2.1; Measuring and Switching Sensor, high resolution, 1 channel; BLOB; Binary Large Object transfer; Common - I&D; Identification and Diagnosis; Extension; Sensor Control Wide; Extension; Quantity detection, switches when value exceeds the setpoint; Function; Locator; Function; ProductURI
Smart Sensor - SSP 4.2.1Measuring and Switching Sensor, high resolution, 1 channel
BLOBBinary Large Object transfer
Common - I&DIdentification and Diagnosis
ExtensionQuantity detection, switches when value exceeds the setpoint
FunctionProductURI
SIO modeyes
Required master port typeA
Min. process cycle time[ms] [ms]1.3
IO-Link resolution pressure[bar] [bar]0.01
IO-Link process data (cyclical)pressure; 32; device status; 4; binary switching information pressure; 2
pressure32
device status4
binary switching information pressure2
IO-Link functions (acyclical)application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter
Supported DeviceIDsdefault; 1869
default1869

Operating conditions

Ambient temperature[°C] [°C]-25...70
Storage temperature[°C] [°C]-40...100
ProtectionIP 67; IP 69; (to DIN EN 60529)

Tests / approvals

EMCDIN EN 61326-1
Shock resistanceDIN EN 60068-2-27; 50 g (11 ms)
DIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-6; 10 g (10...2000 Hz)
DIN EN 60068-2-610 g (10...2000 Hz)
MTTF[years] [years]115
Embedded software includedyes
UL approvalUL approval no.; J063; File number UL; E174189
UL approval no.J063
File number ULE174189
Embedded Software entwickelt nachISO 13849-1 : 2015 (clause 4.6.2)

Mechanical data

Weight[g] [g]692
Housingmanometer housing
Dimensions[mm] [mm]160 x 100 x 57
MaterialsHousing: stainless steel (316L/1.4404); M12 connector: PPSU; Sealing: FKM; viewing glass: laminated safety glass 4 mm
Materials (wetted parts)measuring cell: Al2O3 (ceramics); Process connection: stainless steel (316L/1.4404); Sealing: FKM
Min. pressure cycles100 million
Process connectionthreaded connection G 1/2 DIN EN 837-1
Restrictor element integratedno (can be retrofitted)

Displays / operating elements

3optical operating keys
Displaydisplay rotation: 320°
PointerLED, white ; 72 steps
LED bar graphmulti-colour ; 72 steps
measured valuesalphanumeric display, white 4-digit
switching statusLED, yellow
device statusLED, red/green
Display unitbar; psi
Operating elements3; optical operating keys

Remarks

Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More IFM parts

IFM O8H205Available on requestIFM O8H205
MPN: O8H205 · IFM
Price on request
Request a quote
IFM O8H206Available on requestIFM O8H206
MPN: O8H206 · IFM
Price on request
Request a quote
IFM O8H207Available on requestIFM O8H207
MPN: O8H207 · IFM
Price on request
Request a quote
IFM O8H202Available on requestIFM O8H202
MPN: O8H202 · IFM
Price on request
Request a quote