IFM PE2099
Quick facts
| Availability | Confirmed on request |
| Category | Type PN / PE with digital display |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PE2099 be shipped?
PE2099 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PE2099 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PE2099 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PE2099, subject to availability and destination.
Two switching outputs, one of them programmable as IO-Link and one as analogue output Red/green display for clear identification of the acceptable range The process connection can be rotated for optimum alignment With long-term stability thanks to high overload protection Robust design for use in harsh industrial environments Convenient operation via buttons or parameter setting via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range | -1...1 bar; -1000...1000 mbar; -14.5...14.5 psi; -100...100 kPa |
| -1...1 bar | -1000...1000 mbar |
| Process connection | threaded connection G 1/4 internal thread |
Application
| Special feature | Gold-plated contacts |
| Measuring element | ceramic-capacitive pressure measuring cell |
| Application | for industrial applications |
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -25...80 |
| Min. burst pressure | 30000 mbar; 435 psi; 3000 kPa |
| 30000 mbar | 435 psi |
| Pressure rating | 10000 mbar; 145 psi; 1000 kPa |
| 10000 mbar | 145 psi |
| Vacuum resistance | -1000 mbar; -0.1 MPa |
| -1000 mbar | -0.1 MPa |
| Type of pressure | relative pressure |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | < 35 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 0.3 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250 |
| Switching frequency DC[Hz] [Hz] | < 500 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20; (scalable 1:5) |
| Max. load[Ω] [Ω] | 500 |
| Analogue voltage output[V] [V] | 0...10; (scalable 1:5) |
| Min. load resistance[Ω] [Ω] | 2000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | -1...1 bar; -1000...1000 mbar; -14.5...14.5 psi; -100...100 kPa |
| -1...1 bar | -1000...1000 mbar |
| Set point SP | -985...1000 mbar; -14.3...14.5 psi; -98.5...100 kPa |
| -985...1000 mbar | -14.3...14.5 psi |
| Reset point rP | -995...990 mbar; -14.45...14.4 psi; -99.5...99 kPa |
| -995...990 mbar | -14.45...14.4 psi |
| Analogue start point | -1000...600 mbar; -14.5...8.7 psi; -100...60 kPa |
| -1000...600 mbar | -14.5...8.7 psi |
| Analogue end point | -600...1000 mbar; -8.7...14.5 psi; -60...100 kPa |
| -600...1000 mbar | -8.7...14.5 psi |
| In steps of | 5 mbar; 0.05 psi; 0.5 kPa |
| 5 mbar | 0.05 psi |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,4; (Turn down 1:1) |
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,1; (Turn down 1:1) |
| Long-term stability[% of the span] [% of the span] | < ± 0,05; (Turn down 1:1; per 6 months) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | 0,2; (-25...80 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | 0,2; (-25...80 °C) |
| Notes on the accuracy / deviation | switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1% |
Response times
| Response time[ms] [ms] | < 1.5 |
| Delay time programmable dS, dr[s] [s] | 0...50 |
| Damping process value dAP[s] [s] | 0...4 |
| Damping for the analogue output dAA[s] [s] | 0...4 |
| Max. response time analogue output[ms] [ms] | 3 |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable; Function; Device diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 2.3 |
| Supported DeviceIDs | default; 467 |
| default | 467 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...80 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27; 50 g (11 ms) |
| DIN EN 60068-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 20 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 171 |
| UL approval | UL approval no.; J012 |
| UL approval no. | J012 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 216.45 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 34 / L = 90.7 |
| Materials | stainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC |
| Materials (wetted parts) | stainless steel (316L/1.4404); Al2O3 (ceramics); EPDM |
| Min. pressure cycles | 100 million |
| Tightening torque[Nm] [Nm] | 25...35; (recommended tightening torque; depends on the lubrication, the seal and the pressure load) |
| Process connection | threaded connection G 1/4 internal thread |
| Restrictor element integrated | no (can be retrofitted) |
Displays / operating elements
| Display | Display unit; 5 x LED, green (mbar, psi, kPa, inH2O, inHg); switching status; 2 x LED, yellow; measured values; alphanumeric display, red/green 4-digit |
| Display unit | 5 x LED, green (mbar, psi, kPa, inH2O, inHg) |
| switching status | 2 x LED, yellow |
| measured values | alphanumeric display, red/green 4-digit |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |