IFM PC9013
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | All pressure sensors / vacuum sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PC9013 be shipped?
PC9013 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PC9013 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PC9013 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PC9013, subject to availability and destination.
Precise linear 0...10 V output signal High repeatability and low linearity error With long-term stability thanks to high overload protection Robust stainless steel housing for use in harsh industrial environments Large operating temperature range and high protection rating
Specifications
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 1 |
| Measuring range | 0...750 psi; 0...5170 kPa |
| 0...750 psi | 0...5170 kPa |
| Process connection | threaded connection 7/16" - 20 UNF internal thread - Schrader |
Application
| Application | for industrial applications |
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -25...90 |
| Min. burst pressure | 8702 psi; 60 MPa |
| 8702 psi | 60 MPa |
| Pressure rating | 870 psi; 6 MPa |
| 870 psi | 6 MPa |
| Type of pressure | relative pressure |
Electrical data
| Operating voltage[V] [V] | 16...36 DC |
| Current consumption[mA] [mA] | < 6 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 1 |
| Output signal | analogue signal |
| Number of analogue outputs | 1 |
| Analogue voltage output[V] [V] | 0...10 |
| Min. load resistance[Ω] [Ω] | 2000 |
Measuring/setting range
| Measuring range | 0...750 psi; 0...5170 kPa |
| 0...750 psi | 0...5170 kPa |
Accuracy / deviations
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation[% of the span] [% of the span] | < ± 1,4; (incl. drift when overtightened, zero point and span error) |
| Linearity deviation[% of the span] [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,3 |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (per 6 months) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,1; (-25...90 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,1; (-25...90 °C) |
Operating conditions
| Ambient temperature[°C] [°C] | -25...90 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 67; IP 69K |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 4 kV coupling clamp; EN 61000-4-5 Surge; 1 kV signal for DC units; EN 61000-4-6 HF conducted; 10 V |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 4 kV coupling clamp |
| EN 61000-4-5 Surge | 1 kV signal for DC units |
| EN 61000-4-6 HF conducted | 10 V |
| Shock resistance | DIN IEC 68-2-27; 50 g (11 ms) |
| DIN IEC 68-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6; 20 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 1116 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 74.5 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 22 / L = 61.7 |
| Materials | stainless steel (316L/1.4404); PA |
| Materials (wetted parts) | stainless steel (316L/1.4404) |
| Min. pressure cycles | 50 million |
| Process connection | threaded connection 7/16" - 20 UNF internal thread - Schrader |
Remarks
| Remarks | BFSL = Best Fit Straight Line; LS = limit value setting |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A |