IFM OY5106
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Measuring light grids |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can OY5106 be shipped?
OY5106 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up OY5106 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for OY5106 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for OY5106, subject to availability and destination.
Simple object dimensioning in intralogistics without complex programming High resolution for precise object detection Ease of integration due to a standardised IO-Link interface Selective evaluation of beams to determine the dimensions or distances between objects
Specifications
Product characteristics
| Type of light | infrared light |
| Electrical design | PNP/NPN; (parameterisable) |
| Protection | IP 65; IP 67 |
Electrical data
| Operating voltage[V] [V] | 19.2...28.8 DC |
| Protection class | III |
| Reverse polarity protection | yes |
| Max. power-on delay time[ms] [ms] | 300 |
| Type of light | infrared light |
| Wave length[nm] [nm] | 880 |
| Current consumption[mA] [mA] | 15 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1 |
Outputs
| Electrical design | PNP/NPN; (parameterisable) |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Max. current load per output[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 14 |
| Short-circuit protection | yes |
| Overload protection | yes |
Detection zone
| Number of beams | 105 |
| Sensing field height[mm] [mm] | 1040 |
| Sensing field width (low light intensity)[m] [m] | 0...2 |
| Sensing field width (high light intensity)[m] [m] | 1...10 |
| Distance between beams[mm] [mm] | 10 |
Software / programming
| Parameter setting options | hysteresis / window; second switch point; Switch-on and switch-off delay; switch-on operations; Teach function; light-on/dark-on mode |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Common - I&D; Identification and Diagnosis; Function; Multiple switching signal |
| Common - I&D | Identification and Diagnosis |
| Function | Multiple switching signal |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 10.4 |
| IO-Link process data (cyclical) | process value; 80; device status; 4; binary switching information; 2 |
| process value | 80 |
| device status | 4 |
| binary switching information | 2 |
| IO-Link functions (acyclical) | application specific tag; operating hours counter |
| Supported DeviceIDs | default; 1401 |
| default | 1401 |
| Note | For further information please see the IODD PDF file under "Downloads" |
Operating conditions
| Ambient temperature[°C] [°C] | -10...55 |
| Storage temperature[°C] [°C] | -25...70 |
| Protection | IP 65; IP 67 |
| Max. immunity to extraneous light[klx] [klx] | 10 |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 3 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 3 V; EN 55011; Class A |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 3 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 3 V |
| EN 55011 | Class A |
| Vibration resistance | EN 60068-2-6 Fc; (10-55) Hz 1 mm amplitude, oscillation period 5 min., 30 min. per axis at resonance or 55 Hz |
| EN 60068-2-6 Fc | (10-55) Hz 1 mm amplitude, oscillation period 5 min., 30 min. per axis at resonance or 55 Hz |
| Shock resistance | EN 60068-2-27 Ea; 30 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 Ea | 30 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| MTTF[years] [years] | 82 |
Mechanical data
| Weight[g] [g] | 3.5 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 1113 x 30 x 28 |
| Materials | housing: aluminium; front pane: PC |
| Length L[mm] [mm] | 1113 |
Displays / operating elements
| Display | transmitter; 2 LED; receiver; 3 LED |
| transmitter | 2 LED |
| receiver | 3 LED |
Accessories
| Items supplied | mounting bracket: 2; slot nuts: 2; Nuts |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection - receiver
| Connector | 1 x M12; coding: A |
Electrical connection - transmitter
| Connector | 1 x M12; coding: A |