IFM OPD100
Quick facts
| Availability | Confirmed on request |
| Category | PMD Profiler for object profile checking |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can OPD100 be shipped?
OPD100 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up OPD100 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for OPD100 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for OPD100, subject to availability and destination.
PMD Profiler for object profile checking Inline quality control checks to ensure correct assembly of parts Quick set-up without software Distance-independent measurement for high tolerance on object positioning Immunity to extraneous light – no screening or external illumination required Optional profile visualisation via software
Specifications
Product characteristics
| Type of light | red light |
| Laser protection class | 1 |
| Housing | rectangular |
Electrical data
| Operating voltage[V] [V] | 10...30 DC; ("supply class 2" to cULus) |
| Current consumption[mA] [mA] | < 200; (10 V) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 2 |
| Type of light | red light |
| Wave length[nm] [nm] | 650 |
Inputs / outputs
| Number of inputs and outputs | Number of digital inputs: 1; Number of digital outputs: 2 |
Inputs
| Trigger | external |
| Number of digital inputs | 1 |
Outputs
| Electrical design | PNP/NPN; (parameterisable) |
| Number of digital outputs | 2 |
| Output function | 2 x normally open / normally closed; (parameterisable) |
| Max. current load per output[mA] [mA] | 100 |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring distance (Z-direction)[mm] [mm] | 150...300 |
| Width of the measuring range (X-direction) at min. measuring distance[mm] [mm] | 45; (distance = 150mm) |
| Width of the measuring range (X-direction) at max. measuring distance[mm] [mm] | 90; (distance = 300mm) |
| Sampling rate[Hz] [Hz] | 5 |
Accuracy / deviations
| Measured value resolution | Z-direction 200 µm; X-direction 250 µm |
| Accuracy | Z-direction ± 500 µm; X-direction ± 500 µm; background white (90 % remission) |
Software / programming
| Number of profiles which can be stored | 1 |
| Number of regions of interest | 1 |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM3 (230,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Common - I&D; Identification and Diagnosis; Function; Multiple switching signal; Function; Measurement data, standard resolution |
| Common - I&D | Identification and Diagnosis |
| Function | Measurement data, standard resolution |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 2.3 |
| IO-Link process data (cyclical) | process value; 16; device status; 4; binary switching information; 1 |
| process value | 16 |
| device status | 4 |
| binary switching information | 1 |
| IO-Link functions (acyclical) | operating hours counter; number of trigger events; ROI setting |
| Supported DeviceIDs | default; 1260 |
| default | 1260 |
| Note | For further information please see the IODD PDF file under "Downloads" |
Operating conditions
| Ambient temperature[°C] [°C] | -10...55 |
| Storage temperature[°C] [°C] | -40...60 |
| Protection | IP 65 |
| Max. immunity to extraneous light[klx] [klx] | 20 |
Tests / approvals
| EMC | EN 60947-5-2 |
| Laser protection class | 1 |
| Notes on laser protection | Caution:; laser light; laser class:; 1; EN / IEC60825-1:2007; EN / IEC60825-1:2014; Complies with 21 CFR 1040.10 except for conformance with IEC 60825-1 Ed. 3, as described in Laser Notice No. 56, dated May 8, 2019. |
| Caution: | laser light |
| laser class: | 1 |
| MTTF[years] [years] | 155 |
| UL approval | Ta; -10...55 °C; Enclosure type; Type 1; power supply; Class 2; File number UL; E174191 |
| Ta | -10...55 °C |
| Enclosure type | Type 1 |
| power supply | Class 2 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 535.8 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 88 x 28.5 x 65 |
| Materials | housing: diecast zinc; PPSU; ABS; PMMA; PBT / PC; EPDM; front pane: PMMA |
Displays / operating elements
| Display | switching status; 1 x LED, yellow; Display operation; 1 x LED, green; colour display |
| switching status | 1 x LED, yellow |
| Display operation | 1 x LED, green |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A |