IFM MQ2005
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can MQ2005 be shipped?
MQ2005 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up MQ2005 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for MQ2005 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for MQ2005, subject to availability and destination.
Reliable wear notification when sensing range decreases Indication of the degree of soiling for preventive maintenance Integrated operating hours and switching cycles counter to monitor the lifetime of tools Quick and simple switch point setting User-friendly communication and parameterisation via IO-Link Fast fault localisation thanks to extensive diagnostic functions
Specifications
Product characteristics
| Electrical design | PNP/NPN; (parameterisable) |
| Output function | normally open / normally closed; (parameterisable) |
| Sensing range[mm] [mm] | 5 |
| Communication interface | IO-Link |
| Housing | rectangular |
| Dimensions[mm] [mm] | 20 x 8 x 32 |
Application
| Media | ferrous only |
Electrical data
| Operating voltage[V] [V] | 10...30 DC |
| Rated insulation voltage[V] [V] | 60 |
| Current consumption[mA] [mA] | < 30 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 0.3 |
Outputs
| Electrical design | PNP/NPN; (parameterisable) |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Max. leakage current[mA] [mA] | 0.1 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Short-time current rating of switching output[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 200 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Detection zone
| Sensing range[mm] [mm] | 5 |
| Real sensing range Sr[mm] [mm] | 5 ± 10 % |
| Operating distance[mm] [mm] | 0...4.05 |
Accuracy / deviations
| Correction factor | steel: 1 |
| Hysteresis[% of Sr] [% of Sr] | < 10 |
| Switch point drift[% of Sr] [% of Sr] | -10...20 |
| Repeatability[% of Sr] [% of Sr] | 10 |
Software / programming
| Parameter setting options | hysteresis / window; switch-off delay; switch-on operations; Auto-teach |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Common - I&D; Identification and Diagnosis; Function; Multiple switching signal; Function; Teach channel |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Common - I&D | Identification and Diagnosis |
| Function | Teach channel |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 9.6 |
| IO-Link process data (cyclical) | process value; 16; device status; 4; binary switching information; 4 |
| process value | 16 |
| device status | 4 |
| binary switching information | 4 |
| IO-Link functions (acyclical) | application specific tag; operating hours counter; switching cycles counter |
| Supported DeviceIDs | default; 830 |
| default | 830 |
| Note | For further information please see the IODD PDF file under "Downloads" |
Operating conditions
| Ambient temperature[°C] [°C] | -25...80 |
| Storage temperature[°C] [°C] | -30...85 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V; EN 55011; class B |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| EN 55011 | class B |
| Vibration resistance | EN 60068-2-6 Fc; 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| EN 60068-2-6 Fc | 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| Shock resistance | EN 60068-2-27 Ea; 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| Continuous shock resistance | EN 60068-2-27; 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| MTTF[years] [years] | 1976 |
| UL approval | Ta; -25...60 °C; Enclosure type; Type 1; power supply; Limited Voltage/Current; UL approval no.; C010; File number UL; E174191 |
| Ta | -25...60 °C |
| Enclosure type | Type 1 |
| power supply | Limited Voltage/Current |
| UL approval no. | C010 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 44.9 |
| Housing | rectangular |
| Mounting | flush mountable |
| Dimensions[mm] [mm] | 20 x 8 x 32 |
| Materials | diecast zinc; LED window: TPU; potting: PUR |
Displays / operating elements
| Display | Display operation; 1 x LED, green; switching status; 1 x LED, yellow |
| Display operation | 1 x LED, green |
| switching status | 1 x LED, yellow |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Cable | 0.3 m, PUR, Ø 4.9 mm; flame-retardant (IEC 60332-2, UL: FT2) |
| Connector | 1 x M12; coding: A; Locking: knurled nut, rotatable |