IFM MFH220
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | All magnetic sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can MFH220 be shipped?
MFH220 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up MFH220 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for MFH220 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for MFH220, subject to availability and destination.
Adjustable end position monitoring in the hydraulic cylinder Inline quality control checks to ensure correct assembly of parts Monitoring of critical hydraulic cylinders via switching cycles counter High-pressure resistant up to an operating pressure of 500 bar User-friendly communication and parameterisation via IO-Link
Specifications
Product characteristics
| Electrical design | PNP/NPN |
| Output function | normally open / normally closed; (parameterisable) |
| Sensing range[mm] [mm] | 0...2; (Factory setting 1,65) |
| Communication interface | IO-Link |
| Housing | threaded type |
| Dimensions[mm] [mm] | M12 x 1 / L = 60 |
Application
| Special feature | Full-metal housing |
| Application | hydraulic cylinders |
| Media | detects ferrous metals |
| Min. burst pressure | 2000 bar; 200 MPa |
| 2000 bar | 200 MPa |
| Pressure rating | 500 bar; 50 MPa |
| 500 bar | 50 MPa |
Electrical data
| Operating voltage[V] [V] | 10...30 DC |
| Rated insulation voltage[V] [V] | 60 |
| Current consumption[mA] [mA] | < 20 |
| Protection class | III |
| Reverse polarity protection | yes |
| Max. power-on delay time[ms] [ms] | 300 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
Outputs
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 1.6 |
| Max. leakage current[mA] [mA] | 0.1 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 200 |
| Short-circuit protection | yes |
| Overload protection | yes |
Detection zone
| Sensing range[mm] [mm] | 0...2; (Factory setting 1,65) |
Accuracy / deviations
| Hysteresis[mm] [mm] | 0.05...0.5; (Factory setting 0,1) |
| Switch point drift[% of Sr] [% of Sr] | 10 |
| Repeatability[% of Sr] [% of Sr] | 10 |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1.4 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 4.1.1; Measuring and Switching Sensor, 1 channel; Common - I&D; Identification and Diagnosis; Extension; Object detection, switches when value falls below the setpoint; Function; ProductURI; Function; Teach single value |
| Smart Sensor - SSP 4.1.1 | Measuring and Switching Sensor, 1 channel |
| Common - I&D | Identification and Diagnosis |
| Extension | Object detection, switches when value falls below the setpoint |
| Function | Teach single value |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 4 |
| Supported DeviceIDs | default; 1950 |
| default | 1950 |
Operating conditions
| Pressure peak | 1000 bar; 100 MPa |
| 1000 bar | 100 MPa |
| Ambient temperature[°C] [°C] | -25...120 |
| Protection | IP 65; IP 66; IP 68; IP 69K |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V; EN 55011; class B; DIN ISO 11452-5; 100 V/m |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| EN 55011 | class B |
| DIN ISO 11452-5 | 100 V/m |
| Vibration resistance | EN 60068-2-6 Fc; 20 g 50 sweep cycles, 1 octave per minute, in 3 axes / 10...3000 Hz -20...50 °C |
| EN 60068-2-6 Fc | 20 g 50 sweep cycles, 1 octave per minute, in 3 axes / 10...3000 Hz -20...50 °C |
| Shock resistance | EN 60068-2-27 Ea; 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C |
| EN 60068-2-27 Ea | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
| Continuous shock resistance | EN 60068-2-27 Ea; 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
| UL approval | Ta; -25...65 °C; power supply; Limited Voltage/Current; UL approval no.; C025; File number UL; E174191 |
| Ta | -25...65 °C |
| power supply | Limited Voltage/Current |
| UL approval no. | C025 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 30.64 |
| Housing | threaded type |
| Mounting | flush mountable |
| Dimensions[mm] [mm] | M12 x 1 / L = 60 |
| Thread designation | M12 x 1 |
| Materials | housing: stainless steel (316L / 1.4404); O-ring: FKM; supporting ring: PTFE; plug: PEI |
| Min. pressure cycles | 10 million |
| Tightening torque[Nm] [Nm] | < 25 |
| Full-metal housing | yes |
Accessories
| Items supplied | lock nuts: 1 x M12 |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection - plug