Quick facts

AvailabilityConfirmed on request
CategoryModular transmitter concept
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can LX0025 be shipped?

LX0025 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up LX0025 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for LX0025 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LX0025, subject to availability and destination.

For the reliable level control in tanks and containers Suitable for water, oils and coolants Precise analogue output and user-friendly communication via IO-Link Modular system consisting of evaluation unit and probe Adaptation to different container heights through shortening of the probe User-friendly communication and parameterisation via IO-Link

Specifications

Product characteristics

Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1
Factory settinghydrous media; probe length L = 400 mm
Probe length L[mm] [mm]100...1600
Process connectionG 3/4 external thread

Application

Special featureGold-plated contacts
MediaLiquids
Dielectric constant of the medium≥ 1,8; (for media with a dielectric constant of 1.8...5 (e.g. oils), a coaxial pipe is needed for operation)
Recommended mediawater; hydrous media; oils; oil-based media
Cannot be used forSee the operating instructions, chapter "Function and features".
Medium temperature[°C] [°C]-25...80; (90 < 1 h)
Tank pressure-1...16 bar; -0.1...1.6 MPa
-1...16 bar-0.1...1.6 MPa

Electrical data

Operating voltage[V] [V]18...30 DC
Current consumption[mA] [mA]< 25
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]< 3
Measuring principleguided wave radar

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1

Outputs

Total number of outputs2
Output signalanalogue signal; IO-Link
Electrical designPNP
Number of digital outputs1
Number of analogue outputs1
Analogue current output[mA] [mA]4...20, invertible
Max. load[Ω] [Ω]500
Analogue voltage output[V] [V]0...10, invertible
Min. load resistance[Ω] [Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionthermal, pulsed
Overload protectionyes

Measuring/setting range

Factory settinghydrous media; probe length L = 400 mm
Probe length L[mm] [mm]100...1600
Active range A[mm] [mm]L-40; (when set to oil and oil based media: L-60)
Inactive range I1 / I2[mm] [mm]30 / 10; (when set to oil and oil based media: 30 / 30)
Sampling rate[Hz] [Hz]4

Accuracy / deviations

Repeatability[mm] [mm]± 5
Measuring error[mm] [mm]± 7
Offset error[mm] [mm]5
Resolution[mm] [mm]1
Zero signal (current)[mA] [mA]4
Full signal (voltage)[V] [V]10
Full signal (current)[mA] [mA]20
Temperature drift per 10 K± 0.2 %

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 CDV
SIO modeno
Required master port typeA
Process data analogue1
Min. process cycle time[ms] [ms]2.3
Supported DeviceIDsdefault; 685
default685

Operating conditions

Ambient temperature[°C] [°C]-25...60
Storage temperature[°C] [°C]-40...85
ProtectionIP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68)

Tests / approvals

EMCDIN EN 61000-6-2; DIN EN 61000-6-3; in a closed metal tank; DIN EN 61000-6-4; in plastic or open metal tanks
DIN EN 61000-6-3in a closed metal tank
DIN EN 61000-6-4in plastic or open metal tanks
Shock resistanceDIN EN 60068-2-27; 50 g (11 ms) / 25 g (6 ms) with reference rod 0.5 m
DIN EN 60068-2-2750 g (11 ms) / 25 g (6 ms) with reference rod 0.5 m
Vibration resistanceDIN EN 60068-2-6; 5 g (10...2000 Hz) / 1 g (5...200 Hz) with reference rod 0.5 m
DIN EN 60068-2-65 g (10...2000 Hz) / 1 g (5...200 Hz) with reference rod 0.5 m
MTTF[years] [years]239
UL approvalFile number UL; E355663
File number ULE355663

Mechanical data

Weight[g] [g]431.5
Dimensions[mm] [mm]Ø 50 / L = 86
Materialsstainless steel (304/1.4301); stainless steel (316L/1.4404); FKM; PEI
Materials (wetted parts)stainless steel (303/1.4305); probe connection: stainless steel (316L/1.4435); PTFE; FKM; Sealing: NBR reinforced fibre
Process connectionG 3/4 external thread

Remarks

Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More IFM parts

IFM O8H205Available on requestIFM O8H205
MPN: O8H205 · IFM
Price on request
Request a quote
IFM O8H206Available on requestIFM O8H206
MPN: O8H206 · IFM
Price on request
Request a quote
IFM O8H207Available on requestIFM O8H207
MPN: O8H207 · IFM
Price on request
Request a quote
IFM O8H202Available on requestIFM O8H202
MPN: O8H202 · IFM
Price on request
Request a quote