IFM LR3009
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Modular transmitter concept |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can LR3009 be shipped?
LR3009 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up LR3009 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for LR3009 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LR3009, subject to availability and destination.
For the reliable level control in tanks and containers Suitable for water, oils and coolants Clearly visible 4-digit LED display Modular system consisting of evaluation unit and probe Adaptation to different container heights through shortening of the probe Convenient operation via buttons or parameter setting via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Probe length L[mm] [mm] | 100...1600 |
| Process connection | threaded connection G 3/4 external thread |
Application
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Media | Liquids |
| Dielectric constant of the medium | ≥ 1,8; (for media with a dielectric constant of 1.8...5 (e.g. oils), a coaxial pipe is needed for operation) |
| Recommended media | water; hydrous media; oils; oil-based media |
| Cannot be used for | See the operating instructions, chapter "Function and features". |
| Process temperature[°C] [°C] | -25...80; (90 < 1 h ; see note under remarks) |
| Pressure rating[MPa] [MPa] | 1.6 |
| Vacuum resistance[MPa] [MPa] | -0.1 |
| MAWP for applications according to CRN | 16 bar; 1.6 MPa |
| 16 bar | 1.6 MPa |
Electrical data
| Operating voltage[V] [V] | 18...30 DC |
| Current consumption[mA] [mA] | < 30 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 3 |
| Measuring principle | guided wave radar |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; IO-Link |
| Electrical design | PNP/NPN |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 200 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20, invertible; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Analogue voltage output[V] [V] | 0...10, invertible; (scalable) |
| Min. load resistance[Ω] [Ω] | 2000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | thermal, pulsed |
| Overload protection | yes |
Measuring/setting range
| Probe length L[mm] [mm] | 100...1600 |
| Active range A[mm] [mm] | L-40; (when set to oil and oil based media: L-60) |
| Inactive range I1 / I2[mm] [mm] | 30 / 10; (when set to oil and oil based media: 30 / 30) |
| Sampling rate[Hz] [Hz] | 4 |
| Set point SP[mm] [mm] | 15...L-30 |
| Note on setpoint SP | when set to oil and oil based media: 35...L-30 |
| Reset point rP[mm] [mm] | 10... L-35 |
| Note on reset point rP | when set to oil and oil based media: 30...L-35 |
| In steps of[mm] [mm] | 5 |
| Hysteresis[mm] [mm] | > 5 |
Accuracy / deviations
| Repeatability[mm] [mm] | ± 5 |
| Measuring error[mm] [mm] | ± 7 |
| Offset error[mm] [mm] | 5 |
| Resolution[mm] [mm] | 1 |
| Zero signal (current)[mA] [mA] | 4.0 |
| Full signal (voltage)[V] [V] | 10 |
| Full signal (current)[mA] [mA] | 20 |
| Temperature drift per 10 K | ± 0.2 |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 1 |
| Min. process cycle time[ms] [ms] | 2.3 |
| Supported DeviceIDs | default; 1524 |
| default | 1524 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...60 |
| Storage temperature[°C] [°C] | -40...80 |
| Protection | IP 67 |
Tests / approvals
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3; in a closed metal tank; DIN EN 61000-6-4; in plastic or open metal tanks |
| DIN EN 61000-6-3 | in a closed metal tank |
| DIN EN 61000-6-4 | in plastic or open metal tanks |
| Shock resistance | DIN EN 60068-2-27; 50 g (11 ms) / 25 g (6 ms) with reference rod 0.5 m |
| DIN EN 60068-2-27 | 50 g (11 ms) / 25 g (6 ms) with reference rod 0.5 m |
| Vibration resistance | DIN EN 60068-2-6; 5 g (10...2000 Hz) / 1 g (5...200 Hz) with reference rod 0.5 m |
| DIN EN 60068-2-6 | 5 g (10...2000 Hz) / 1 g (5...200 Hz) with reference rod 0.5 m |
| MTTF[years] [years] | 195 |
| UL approval | UL approval no.; H00X |
| UL approval no. | H00X |
Mechanical data
| Weight[g] [g] | 378.458 |
| Dimensions[mm] [mm] | Ø 50 / L = 99 |
| Materials | stainless steel (304/1.4301); stainless steel (316L/1.4404); FKM; PBT; PC; PEI; TPE-V |
| Materials (wetted parts) | stainless steel (303/1.4305); probe connection: stainless steel (316L/1.4435); PTFE; FKM; Sealing: NBR reinforced fibre |
| Process connection | threaded connection G 3/4 external thread |
Displays / operating elements
| Display | Display unit; 2 x LED, green; switching status; 1 x LED, yellow; level; alphanumeric display, 4-digit; parameter setting; alphanumeric display, 4-digit |
| Display unit | 2 x LED, green |
| switching status | 1 x LED, yellow |
| level | alphanumeric display, 4-digit |
| parameter setting | alphanumeric display, 4-digit |
Remarks
| Remarks | For high process temperatures: The temperature at the process connection is decisive. The actual medium temperature may be higher. |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |