IFM LR2750
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Modular transmitter concept |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can LR2750 be shipped?
LR2750 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up LR2750 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for LR2750 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LR2750, subject to availability and destination.
For the reliable level control in tanks and containers Hygienic design for the requirements of the food and beverage industry Clearly visible 4-digit LED display Modular system consisting of evaluation unit and probe Adaptation to different container heights through shortening of the probe Convenient operation via buttons or parameter setting via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Probe length L[mm] [mm] | 150...2000 |
| Process connection | threaded connection G 1 external thread Aseptoflex Vario |
Application
| Special feature | Gold-plated contacts |
| Application | hygienic systems |
| Media | Liquids |
| Dielectric constant of the medium | > 5 |
| Recommended media | water; hydrous media |
| Process temperature[°C] [°C] | -40...150; (see note under remarks) |
| Pressure rating | 40 bar; 4 MPa |
| 40 bar | 4 MPa |
| Vacuum resistance | -1000 mbar; -0.1 MPa |
| -1000 mbar | -0.1 MPa |
| MAWP for applications according to CRN[bar] [bar] | 25 |
Electrical data
| Operating voltage[V] [V] | 18...30 DC |
| Current consumption[mA] [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 3 |
| Measuring principle | guided wave radar |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; IO-Link |
| Electrical design | PNP/NPN |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 150; (200 (...60 °C)) |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20, invertible; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Probe length L[mm] [mm] | 150...2000 |
| Active range A[mm] [mm] | L-40 |
| Inactive range I1 / I2[mm] [mm] | 30 / 10 |
| Sampling rate[Hz] [Hz] | 4 |
| Set point SP[mm] [mm] | 15...L-30 |
| Reset point rP[mm] [mm] | 10... L-35 |
| In steps of[mm] [mm] | 1 |
| Hysteresis[mm] [mm] | > 5 |
Accuracy / deviations
| Measuring error[mm] [mm] | ± 7 |
| Offset error[mm] [mm] | 5 |
| Resolution[mm] [mm] | 1 |
| Zero signal (current)[mA] [mA] | 4.0 |
| Full signal (current)[mA] [mA] | 20 |
| Temperature drift per 10 K | ± 0.2 % |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable; Function; Device diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 2.3 |
| Supported DeviceIDs | default; 478 |
| default | 478 |
Operating conditions
| Ambient temperature[°C] [°C] | -40...80 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 68; IP 69K |
Tests / approvals
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3; : in a closed metal tank; DIN EN 61000-6-4; : in plastic or open metal tanks |
| DIN EN 61000-6-3 | : in a closed metal tank |
| DIN EN 61000-6-4 | : in plastic or open metal tanks |
| Shock resistance | DIN EN 60068-2-27; 50 g (11 ms) / 20 g (6 ms) with reference rod 0.5 m |
| DIN EN 60068-2-27 | 50 g (11 ms) / 20 g (6 ms) with reference rod 0.5 m |
| Vibration resistance | DIN EN 60068-2-6; 20 g (10...2000 Hz) / 1 g (5...200 Hz) with reference rod 0.5 m |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) / 1 g (5...200 Hz) with reference rod 0.5 m |
| MTTF[years] [years] | 216 |
Mechanical data
| Weight[g] [g] | 330.75 |
| Materials | stainless steel (316L/1.4404); PEI; PFA; PBT; FKM |
| Materials (wetted parts) | stainless steel (316L/1.4404); PEEK; EPDM |
| Process connection | threaded connection G 1 external thread Aseptoflex Vario |
| Surface characteristics Ra/Rz of the wetted parts | Ra < 0.8 µm |
Displays / operating elements
| Display | Display unit; 3 x LED, green; switching status; 2 x LED, yellow; level; alphanumeric display, 4-digit; parameter setting; alphanumeric display, 4-digit |
| Display unit | 3 x LED, green |
| switching status | 2 x LED, yellow |
| level | alphanumeric display, 4-digit |
| parameter setting | alphanumeric display, 4-digit |
Remarks
| Notes | For high process temperatures: The temperature at the process connection is decisive. The actual medium temperature may be higher.; For 3-A applications, the medium temperature is limited to 121 °C and COP cleaning is required. |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |