Quick facts

AvailabilityConfirmed on request
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can LL8024 be shipped?

LL8024 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up LL8024 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for LL8024 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LL8024, subject to availability and destination.

Reliable level detection in containers and tanks For use in water, oils and coolants Easy adjustment to the medium to be measured Clearly visible 4-digit LED display Two programmable switching outputs for leakage detection

Specifications

Product characteristics

Number of inputs and outputsNumber of digital outputs: 4
Probe length L[mm] [mm]728

Application

Special featureGold-plated contacts
Mediahydrous coolants; oils; water; media similar to water
Dielectric constant of the medium> 2
Cannot be used forextremely conductive media; adhering media; granulates; bulk material; acids; alkali
Tank pressure0.5; (when mounting with mounting accessories: E43001 - E43007, E43019) bar; 0.05; (when mounting with mounting accessories: E43001 - E43007, E43019) MPa
0.5; (when mounting with mounting accessories: E43001 - E43007, E43019) bar0.05; (when mounting with mounting accessories: E43001 - E43007, E43019) MPa
Medium temperature[°C] [°C]0...35; (LL8024 + E43102: 0...55; For water and hydrous media with temperatures > 35 °C install the unit into a climatic tube.)
Medium temperature short time[°C] [°C]0...90

Electrical data

Operating voltage[V] [V]18...30 DC; ("supply class 2" to cULus)
Current consumption[mA] [mA]< 60
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]3
Measuring principlecapacitive

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 4

Outputs

Total number of outputs4
Output signalswitching signal
Electrical designPNP
Number of digital outputs4
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2.5
Permanent current rating of switching output DC[mA] [mA]200
Short-circuit protectionyes
Type of short-circuit protectionthermal, pulsed
Overload protectionyes

Measuring/setting range

Probe length L[mm] [mm]728
Active range A[mm] [mm]585
Inactive range I1 / I2[mm] [mm]102 / 40
Set point SP[mm] [mm]60...580
Reset point rP[mm] [mm]50...570
In steps of[mm] [mm]10
Hysteresis[mm] [mm]10
Overflow switch point OP[mm] [mm]200 - 240 - 280 - 310 - 350 - 390 - 420 - 460 - 500 - 530 - 570 -610
Hysteresis, OP[mm] [mm]4
Display range[°C] [°C]-10...100

Accuracy / deviations

Measuring error[% of the final value] [% of the final value]± 5
Repeatability± 2

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; SP/rP position; OP position; adjustment OP; medium selection; offset setting; Display unit; settings for leakage monitoring

Operating conditions

Ambient temperature[°C] [°C]0...60
Storage temperature[°C] [°C]-25...80
ProtectionIP 67

Tests / approvals

EMCEN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated10 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-6 HF conducted10 V
Shock resistanceDIN EN 60068-2-29; 15 g (11 ms)
DIN EN 60068-2-2915 g (11 ms)
Vibration resistanceDIN EN 60068-2-6; 5 g (10...2000 Hz)
DIN EN 60068-2-65 g (10...2000 Hz)
MTTF[years] [years]202

Mechanical data

Weight[g] [g]534.8
Dimensions[mm] [mm]Ø 16
Materialsstainless steel (304/1.4301); FKM; NBR; PBT; PC; PEI; PP; TPE-V
Materials (wetted parts)PP

Displays / operating elements

Displaydisplay unit / status; 4 x LED, green; switching status; 4 x LED, yellow; level; alphanumeric display, 4-digit; parameter setting; alphanumeric display, 4-digit
display unit / status4 x LED, green
switching status4 x LED, yellow
levelalphanumeric display, 4-digit
parameter settingalphanumeric display, 4-digit

Remarks

Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More IFM parts

IFM O8H205Available on requestIFM O8H205
MPN: O8H205 · IFM
Price on request
Request a quote
IFM O8H206Available on requestIFM O8H206
MPN: O8H206 · IFM
Price on request
Request a quote
IFM O8H207Available on requestIFM O8H207
MPN: O8H207 · IFM
Price on request
Request a quote
IFM O8H202Available on requestIFM O8H202
MPN: O8H202 · IFM
Price on request
Request a quote