IFM LL8022
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can LL8022 be shipped?
LL8022 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up LL8022 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for LL8022 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LL8022, subject to availability and destination.
Reliable level detection in containers and tanks For use in water, oils and coolants Easy adjustment to the medium to be measured Clearly visible 4-digit LED display Two programmable switching outputs for leakage detection
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 4 |
| Probe length L[mm] [mm] | 264 |
Application
| Special feature | Gold-plated contacts |
| Media | hydrous coolants; oils; water; media similar to water |
| Dielectric constant of the medium | > 2 |
| Cannot be used for | extremely conductive media; adhering media; granulates; bulk material; acids; alkali |
| Tank pressure | 0.5; (when mounting with mounting accessories: E43001 - E43007, E43019) bar; 0.05; (when mounting with mounting accessories: E43001 - E43007, E43019) MPa |
| 0.5; (when mounting with mounting accessories: E43001 - E43007, E43019) bar | 0.05; (when mounting with mounting accessories: E43001 - E43007, E43019) MPa |
| Medium temperature[°C] [°C] | 0...35; (LL8022 + E43100: 0...65; For water and hydrous media with temperatures > 35 °C install the unit into a climatic tube.) |
| Medium temperature short time[°C] [°C] | 0...90 |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; ("supply class 2" to cULus) |
| Current consumption[mA] [mA] | < 60 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 3 |
| Measuring principle | capacitive |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 4 |
Outputs
| Total number of outputs | 4 |
| Output signal | switching signal |
| Electrical design | PNP |
| Number of digital outputs | 4 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 200 |
| Short-circuit protection | yes |
| Type of short-circuit protection | thermal, pulsed |
| Overload protection | yes |
Measuring/setting range
| Probe length L[mm] [mm] | 264 |
| Active range A[mm] [mm] | 195 |
| Inactive range I1 / I2[mm] [mm] | 53 / 15 |
| Set point SP[mm] [mm] | 25...190 |
| Reset point rP[mm] [mm] | 20...185 |
| In steps of[mm] [mm] | 5 |
| Hysteresis[mm] [mm] | 5 |
| Overflow switch point OP[mm] [mm] | 69 - 82 - 94 - 106 - 118 - 130 - 143 - 155 - 167 - 179 - 191 - 204 |
| Hysteresis, OP[mm] [mm] | 2 |
| Display range[°C] [°C] | -10...100 |
Accuracy / deviations
| Measuring error[% of the final value] [% of the final value] | ± 5 |
| Repeatability | ± 2 |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; SP/rP position; OP position; adjustment OP; medium selection; offset setting; Display unit; settings for leakage monitoring |
Operating conditions
| Ambient temperature[°C] [°C] | 0...60 |
| Storage temperature[°C] [°C] | -25...80 |
| Protection | IP 67 |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| Shock resistance | DIN EN 60068-2-29; 15 g (11 ms) |
| DIN EN 60068-2-29 | 15 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 5 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 202 |
Mechanical data
| Weight[g] [g] | 344.6 |
| Dimensions[mm] [mm] | Ø 16 |
| Materials | stainless steel (304/1.4301); FKM; NBR; PBT; PC; PEI; PP; TPE-V |
| Materials (wetted parts) | PP |
Displays / operating elements
| Display | display unit / status; 4 x LED, green; switching status; 4 x LED, yellow; level; alphanumeric display, 4-digit; parameter setting; alphanumeric display, 4-digit |
| display unit / status | 4 x LED, green |
| switching status | 4 x LED, yellow |
| level | alphanumeric display, 4-digit |
| parameter setting | alphanumeric display, 4-digit |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |