IFM KI0209
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | All capacitive sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KI0209 be shipped?
KI0209 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KI0209 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KI0209 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KI0209, subject to availability and destination.
Easy setting of the sensing range via potentiometer With combined AC/DC output stage Two-wire technology High noise immunity Clearly visible indication of the switching status
Specifications
Product characteristics
| Output function | normally closed |
| Sensing range[mm] [mm] | 15 |
| Housing | threaded type |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 81 |
Electrical data
| Operating voltage[V] [V] | 20...250 AC/DC |
| Protection class | II |
| Reverse polarity protection | no |
| Max. power-on delay time[ms] [ms] | 300 |
Outputs
| Output function | normally closed |
| Max. voltage drop switching output DC[V] [V] | 8 |
| Max. voltage drop switching output AC[V] [V] | 10 |
| Minimum load current[mA] [mA] | 5 |
| Max. leakage current[mA] [mA] | 2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC) |
| Permanent current rating of switching output AC[mA] [mA] | 200; (350 (...50 °C)) |
| Permanent current rating of switching output DC[mA] [mA] | 200; (350 (...50 °C)) |
| Short-time current rating of switching output[mA] [mA] | 2200; (20 ms / 0,5 Hz) |
| Switching frequency AC[Hz] [Hz] | < 2 |
| Switching frequency DC[Hz] [Hz] | < 2 |
| Short-circuit proof | no |
| Overload protection | no |
Detection zone
| Sensing range[mm] [mm] | 15 |
| Sensing range adjustable | yes |
| Factory setting sensing range[mm] [mm] | 15 |
| Real sensing range Sr[mm] [mm] | 15 ± 10 % |
| Operating distance[mm] [mm] | 0...12.1 |
Accuracy / deviations
| Correction factor | glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 |
| Hysteresis[% of Sr] [% of Sr] | 1...15 |
| Switch point drift[% of Sr] [% of Sr] | -15...15 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...70 |
| Protection | IP 65 |
| Increased immunity | yes; (increased immunity to conducted radio frequency interference) |
Tests / approvals
| EMC | EN 60947-5-2 |
Mechanical data
| Weight[g] [g] | 195.5 |
| Housing | threaded type |
| Mounting | non-flush mountable |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 81 |
| Thread designation | M30 x 1.5 |
| Materials | housing: PBT; end cap: TPE |
Displays / operating elements
| Display | switching status; 1 x LED, yellow |
| switching status | 1 x LED, yellow |
Electrical connection
| Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
Accessories
| Items supplied | lock nuts: 2 |
Remarks
| Remarks | Recommendation: Check the safe functioning of the unit after a short circuit. |
| Pack quantity | 1 pcs. |
Electrical connection
| Cable | 2 m, PVC; 2 x 0.5 mm² |