IFM KD001A
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | All capacitive sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KD001A be shipped?
KD001A is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KD001A in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KD001A and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KD001A, subject to availability and destination.
With combined AC/DC output and two-wire technology Long sensing range of 60 mm Easy setting of the sensing range via potentiometer For applications in hazardous areas Robust housing for use in harsh industrial environments
Specifications
Product characteristics
| Output function | normally open / normally closed; (selectable) |
| Sensing range[mm] [mm] | 60 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 105 x 80 x 42 |
Electrical data
| Operating voltage[V] [V] | 20...250 AC/DC |
| Protection class | II |
| Reverse polarity protection | no |
| Measuring principle | capacitive |
Outputs
| Output function | normally open / normally closed; (selectable) |
| Max. voltage drop switching output DC[V] [V] | 8 |
| Max. voltage drop switching output AC[V] [V] | 10 |
| Minimum load current[mA] [mA] | 5 |
| Max. leakage current[mA] [mA] | 2.5 (250 V AC) / 1.7 (110 V AC) / 1.3 (24 V DC) |
| Permanent current rating of switching output AC[mA] [mA] | 130; (250 (...40 °C)) |
| Permanent current rating of switching output DC[mA] [mA] | 130; (250 (...40 °C)) |
| Short-time current rating of switching output[mA] [mA] | 1500; (20 ms / 0,5 Hz) |
| Switching frequency AC[Hz] [Hz] | 4 |
| Switching frequency DC[Hz] [Hz] | 4 |
| Notes on switching frequency[Hz] [Hz] | only for resistive loads; 2 Hz for utilisation category AC-140 |
| Short-circuit proof | no |
| Overload protection | no |
Detection zone
| Sensing range[mm] [mm] | 60 |
| Sensing range adjustable | yes |
| Factory setting sensing range[mm] [mm] | 60 |
| Real sensing range Sr[mm] [mm] | 60 ± 10 % |
Accuracy / deviations
| Correction factor | glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 |
| Hysteresis[% of Sr] [% of Sr] | 1...15 |
| Switch point drift[% of Sr] [% of Sr] | -15...15 |
Operating conditions
| Ambient temperature[°C] [°C] | -20...60 |
| Protection | IP 65 |
| Increased immunity | yes |
Tests / approvals
| ATEX marking | II 3D Ex tc IIIC T90°C Dc X IP65 |
| EMC | EN 60947-5-2 |
| MTTF[years] [years] | 270 |
Mechanical data
| Weight[g] [g] | 281.5 |
| Housing | rectangular |
| Mounting | non-flush mountable |
| Dimensions[mm] [mm] | 105 x 80 x 42 |
| Materials | PPE modified; PA |
| Tightening torque[Nm] [Nm] | housing screws: 0,9 Nm; screws: 4 Nm |
Displays / operating elements
| Display | switching status; 1 x LED, yellow |
| switching status | 1 x LED, yellow |
Electrical connection
| Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting; Place the fuse outside the hazardous area. |
Remarks
| Remarks | Recommendation: Check the safe functioning of the unit after a short circuit. |
| Pack quantity | 1 pcs. |
Electrical connection
| terminals | 0.34...2.5 mm²; Cable sheath: Ø 5...9 mm; Cable gland: M20 X 1.5 |