Quick facts
| Availability | Confirmed on request |
| Category | Static inclination sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can JN2200 be shipped?
JN2200 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up JN2200 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for JN2200 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for JN2200, subject to availability and destination.
Precise measurement of angles of inclination on X and Y axes High measurement accuracy across the total angular range in two axes With two programmable switching outputs, two scalable analogue outputs and IO-Link Compact and robust housing High protection rating for the requirements of harsh industrial environments User-friendly communication and parameterisation via IO-Link
Specifications
Product characteristics
| Measuring principle | MEMS capacitive |
| Communication interface | IO-Link |
| Number of measurement axes | 2 |
| Angular range[°] [°] | ± 180 |
Application
| Function principle | static |
| Application | High-precision inclination measurement in 2 axes for mobile and industrial applications |
Electrical data
| Operating voltage[V] [V] | 9.2...30 DC; (voltage output: 12...30 DC; IO-Link: 18...30 DC) |
| Current consumption[mA] [mA] | 90; (24 V DC, 25 °C) |
| Max. current consumption[mA] [mA] | 330; (9,2 V DC; -40 °C) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 300; (warm-up time; Max. initialisation time: 1000 ms) |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 2 |
Outputs
| Total number of outputs | 4 |
| Output signal | analogue signal; switching signal |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (programmable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 125; (125 mA (85° C); 200 mA (60° C); 250 mA (40° C)) |
| Number of analogue outputs | 2 |
| Analogue current output[mA] [mA] | 4...20; (in case of a fault: 2 mA) |
| Max. load[Ω] [Ω] | 220; (220 (9,2…15 V) / 500 (15…30 V)) |
| Analogue voltage output[V] [V] | 2...10; (in case of a fault: 1 V) |
| Min. load resistance[Ω] [Ω] | 1000; (10000 (12...13,5 V) / 1000 (13,5...30 V)) |
| Precision analogue output[%] [%] | ≤ 1 |
| Short-circuit protection | yes |
| Overload protection | yes |
Measuring/setting range
| Measuring principle | MEMS capacitive |
| Number of measurement axes | X/Y/Z parameterisable |
| Angular range[°] [°] | ± 180 |
| Limit frequency[Hz] [Hz] | 0.5...10; (parameterisable) |
| Measuring range of vibration[g] [g] | 16; (± 2; ± 4; ±8 g parameterisable) |
| Measuring range of vibration[mm/s] [mm/s] | 3200 |
| Frequency range[Hz] [Hz] | 0.1...400 |
Accuracy / deviations
| Accuracy[°] [°] | ≤ ± 0,5; (absolute) |
| Hysteresis[°] [°] | ≤ ± 0,05 |
| Repeatability[°] [°] | ≤ ± 0,1 |
| Resolution[°] [°] | 0.05 |
| Temperature coefficient[1/K] [1/K] | ≤ ± 0,02 ° |
Software / programming
| Parameter setting options | angle (X/Y) / vibration (Veff / aPeak); hysteresis / window; switch points; switching logic; fault indication; self-test; current/voltage output |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable; Function; Device diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 2 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 5 |
| Supported DeviceIDs | default; 416 |
| default | 416 |
Operating conditions
| Ambient temperature[°C] [°C] | -40...85 |
| Storage temperature[°C] [°C] | -40...85 |
| Protection | IP 65; IP 67; IP 68; IP 69K |
Tests / approvals
| EMC | DIN EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; DIN EN 61000-4-3 HF radiated; 10 V/m; DIN EN 61000-4-4 Burst; 2 kV; DIN EN 61000-4-6 HF conducted; 10 V; DIN EN 55022 class B / CISPR 16-2-3; 30 - 1000 MHz; CISPR 25 ECE R 10; 30 - 1000 MHz narrowband and broadband; ISO 11452-2 ECE R 10; 20 - 2000 MHz / 30 V/m; ISO 7637-2 ECE R 10; pulse 1, 2a, 2b, 3a, 3b, 4, and pulse emission during operation, switching-on, switching-off; ISO 7637-3; - 80 V pulse a / + 80 V pulse b |
| DIN EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| DIN EN 61000-4-3 HF radiated | 10 V/m |
| DIN EN 61000-4-4 Burst | 2 kV |
| DIN EN 61000-4-6 HF conducted | 10 V |
| DIN EN 55022 class B / CISPR 16-2-3 | 30 - 1000 MHz |
| CISPR 25 ECE R 10 | 30 - 1000 MHz narrowband and broadband |
| ISO 11452-2 ECE R 10 | 20 - 2000 MHz / 30 V/m |
| ISO 7637-2 ECE R 10 | pulse 1, 2a, 2b, 3a, 3b, 4, and pulse emission during operation, switching-on, switching-off |
| ISO 7637-3 | - 80 V pulse a / + 80 V pulse b |
| Shock resistance | DIN EN 60068-2-27; 100 g 1 ms / 10000 impacts per axis (X/Y); DIN EN 60068-2-29; 30 g 6 ms / 24000 shock (bump) |
| DIN EN 60068-2-27 | 100 g 1 ms / 10000 impacts per axis (X/Y) |
| DIN EN 60068-2-29 | 30 g 6 ms / 24000 shock (bump) |
| Vibration resistance | DIN EN 60068-2-64; 10...2000 Hz Test VII / random, mounting place car body; DIN EN 60068-2-6; 10...500 Hz / 10 g 10 cycles/axis, sine |
| DIN EN 60068-2-64 | 10...2000 Hz Test VII / random, mounting place car body |
| DIN EN 60068-2-6 | 10...500 Hz / 10 g 10 cycles/axis, sine |
| Salt spray test | DIN EN 60068-2-52; severity level 5 (motor vehicle) |
| DIN EN 60068-2-52 | severity level 5 (motor vehicle) |
| Damp heat | DIN EN 60068-2-30; 55 °C cyclic upper temperature / 95 % rh 2 cycles of 24 h |
| DIN EN 60068-2-30 | 55 °C cyclic upper temperature / 95 % rh 2 cycles of 24 h |
| MTTF[years] [years] | 176 |
| Standard | Compliant with ECE R 10, rev. 5; ISO 7637-3: 2007-07 |
Mechanical data
| Weight[g] [g] | 410 |
| Dimensions[mm] [mm] | 90 x 62 x 33.2 |
| Materials | housing: diecast zinc nickel-plated |
| Installation position | horizontal |
Displays / operating elements
| Display | operation; 1 x LED, green; switch point; 1 x LED, yellow |
| operation | 1 x LED, green |
| switch point | 1 x LED, yellow |
Accessories
| Items supplied | Protective cover |
Remarks
| Remarks | the device complies with overvoltage category II |
| Pack quantity | 1 pcs. |
Electrical connection - digital
| Connector | 1 x M12; coding: A |
Electrical connection - analogue
| Connector | 1 x M12; coding: A |