IFM IN0117
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Sensors for valve actuators |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can IN0117 be shipped?
IN0117 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up IN0117 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for IN0117 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for IN0117, subject to availability and destination.
For monitoring valve positions For reliable position feedback on valve actuators Non-contact and self-cleaning system Quick and secure mounting with only three screws High shock and vibration resistance
Specifications
Product characteristics
| Output function | 2 x normally open |
| Sensing range[mm] [mm] | 4 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 40 x 26 x 26 |
Application
| Application | position sensor for valve actuators |
Electrical data
| Frequency AC[Hz] [Hz] | 47...63 |
| Operating voltage[V] [V] | 20...140 AC / 10...140 DC |
| Protection class | I |
| Reverse polarity protection | no |
Outputs
| Output function | 2 x normally open |
| Max. voltage drop switching output DC[V] [V] | 5 |
| Max. voltage drop switching output AC[V] [V] | 5 |
| Minimum load current[mA] [mA] | 5 |
| Max. leakage current[mA] [mA] | 0.8 |
| Permanent current rating of switching output AC[mA] [mA] | 200 |
| Permanent current rating of switching output DC[mA] [mA] | 200 |
| Short-time current rating of switching output[mA] [mA] | 900; (20 ms / 0,5 Hz) |
| Switching frequency AC[Hz] [Hz] | 25 |
| Switching frequency DC[Hz] [Hz] | 25 |
| Short-circuit proof | no |
| Overload protection | no |
Detection zone
| Sensing range[mm] [mm] | 4 |
| Real sensing range Sr[mm] [mm] | 4 ± 10 % |
| Operating distance[mm] [mm] | 0...3.25 |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2 |
| Hysteresis[% of Sr] [% of Sr] | 3...15 |
| Switch point drift[% of Sr] [% of Sr] | -10...10 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...80 |
| Protection | IP 67 |
Tests / approvals
| EMC | EN 60947-5-2; EN 55011; class B |
| EN 55011 | class B |
| MTTF[years] [years] | 502 |
Mechanical data
| Weight[g] [g] | 78.5 |
| Housing | rectangular |
| Mounting | non-flush mountable |
| Dimensions[mm] [mm] | 40 x 26 x 26 |
| Materials | stainless steel (303/1.4305); PBT |
Displays / operating elements
| Display | switching status; 2 x LED, red |
| switching status | 2 x LED, red |
Electrical connection
| Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting; Place the fuse outside the hazardous area. |
Remarks
| Remarks | Recommendation: Check the safe functioning of the unit after a short circuit. |
| Pack quantity | 1 pcs. |
Electrical connection - plug
| Connector | 1 x 7/8"; coding: A |