IFM IM5140
Quick facts
| Availability | Confirmed on request |
| Category | All inductive sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can IM5140 be shipped?
IM5140 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up IM5140 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for IM5140 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for IM5140, subject to availability and destination.
Non-contact measurement of distances up to 26 mm Precise linearised current output Wide operating temperature range High repeatability LED display to check working range and operation Reliable transmission of the distance as linearised process value via IO-Link Normally closed / normally open and PNP/NPN adjustable via IO-Link
Specifications
Product characteristics
| Electrical design | PNP/NPN; (parameterisable) |
| Output function | normally open / normally closed; (parameterisable) |
| Communication interface | IO-Link |
| Housing | rectangular |
| Dimensions[mm] [mm] | 40 x 40 x 54 |
Electrical data
| Operating voltage[V] [V] | 15...30 DC |
| Current consumption[mA] [mA] | < 33 |
| Protection class | II |
| Reverse polarity protection | yes |
Outputs
| Electrical design | PNP/NPN; (parameterisable) |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 100 |
| Analogue voltage output[V] [V] | 0...10; (linear; gradient: 0,714 V/mm; for frontal approach and for target made of mild steel: 45 x 45 x 1 mm) |
| Min. load resistance[Ω] [Ω] | 2000 |
| Short-circuit protection | yes |
| Overload protection | yes |
Detection zone
| Measuring range[mm] [mm] | 1...15 |
| Switch point IO-Link[mm] [mm] | 2.37...13.99 |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.9 / brass: 0.4 / aluminium: 0.4 / copper: 0.3 |
| Hysteresis[% of Sr] [% of Sr] | 3...15 |
| Note on hysteresis | parameterisable |
| Linearity error of analogue output[%] [%] | ± 2; (of the final value of the measuring range) |
| Repeatability analogue output[%] [%] | ± 2; (of the final value of the measuring range) |
| Temperature coefficient[%/K vom MEW] [%/K vom MEW] | ±0,15 |
| Temperature drift | ± 5 %; (of the final value of the measuring range) |
Response times
| Response time[ms] [ms] | < 20 |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Common - I&D; Identification and Diagnosis; Function; Multiple switching signal; Function; Teach channel |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Common - I&D | Identification and Diagnosis |
| Function | Teach channel |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 3.2 |
| IO-Link process data (cyclical) | process value; 16; device status; 4; binary switching information; 2 |
| process value | 16 |
| device status | 4 |
| binary switching information | 2 |
| IO-Link functions (acyclical) | switching cycles counter; switch-on cycle counter; operating hours counter; internal temperature; application specific tag |
| Supported DeviceIDs | default; 1206 |
| default | 1206 |
| Note | For further information please see the IODD PDF file under "Downloads" |
Operating conditions
| Ambient temperature[°C] [°C] | -25...80 |
| Protection | IP 67 |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V; EN 55011; class B |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| EN 55011 | class B |
| MTTF[years] [years] | 230 |
| Embedded software included | yes |
| UL approval | Ta; -25...70 °C; Enclosure type; Type 1; power supply; Limited Voltage/Current; UL approval no.; A026; File number UL; E174191 |
| Ta | -25...70 °C |
| Enclosure type | Type 1 |
| power supply | Limited Voltage/Current |
| UL approval no. | A026 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 152.5 |
| Housing | rectangular |
| Sensing face | 5 positions selectable |
| Mounting | flush mountable |
| Dimensions[mm] [mm] | 40 x 40 x 54 |
| Materials | PA; brass white bronze coated |
Displays / operating elements
| Display | target in measuring range; 1 x LED, yellow lights; target outside measuring range; 1 x LED, yellow flashing; operation; LED, green |
| target in measuring range | 1 x LED, yellow lights |
| target outside measuring range | 1 x LED, yellow flashing |
| operation | LED, green |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection - plug
| Connector | 1 x M12; coding: A |









