IFM IIM219
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | All inductive sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can IIM219 be shipped?
IIM219 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up IIM219 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for IIM219 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for IIM219, subject to availability and destination.
E1 type approval by the Kraftfahrt-Bundesamt (German Federal Motor Transport Authority) Wide operating temperature range High ingress protection for the requirements of harsh environmental conditions High EMC resistance according to automotive standards Large operating voltage range
Specifications
Product characteristics
| Electrical design | PNP |
| Output function | normally open |
| Sensing range[mm] [mm] | 12 |
| Housing | threaded type |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 81 |
Application
| Special feature | Increased sensing range |
| Application | Use in mobile and harsh applications |
Electrical data
| Operating voltage[V] [V] | 10...60 DC |
| Current consumption[mA] [mA] | < 10 |
| Protection class | II |
| Reverse polarity protection | yes |
Outputs
| Electrical design | PNP |
| Output function | normally open |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 200 |
| Switching frequency DC[Hz] [Hz] | 100 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Detection zone
| Sensing range[mm] [mm] | 12 |
| Operating distance[mm] [mm] | 0...9.72 |
| Increased sensing range | yes |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.45 / copper: 0.35 |
| Hysteresis[% of Sr] [% of Sr] | 1...20 |
Operating conditions
| Ambient temperature[°C] [°C] | -40...85 |
| Protection | IP 67; IP 69K |
Tests / approvals
| EMC | automotive area; noise emission and noise immunity: ECE R10; E1 type approval; noise immunity according to DIN ISO 11452-2; 100 V/m; conducted interference in 24 V networks to ISO 7637-2: 2004 (pulse 1 to 4) and ISO16750-2: 2012 (load dump); pulse; 1 2a 2b 3a 3b 4 Load dump; severity level; III III III III III III Test A; failure criterion; C A C A A C C; EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-5 Surge; 0,5 kV mains line to line; EN 61000-4-6 HF conducted; 10 V; EN 55011; class B |
| noise emission and noise immunity: ECE R10 | E1 type approval |
| noise immunity according to DIN ISO 11452-2 | 100 V/m |
| pulse | 1 2a 2b 3a 3b 4 Load dump |
| severity level | III III III III III III Test A |
| failure criterion | C A C A A C C |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-5 Surge | 0,5 kV mains line to line |
| EN 61000-4-6 HF conducted | 10 V |
| EN 55011 | class B |
| Vibration resistance | EN 60068-2-6 Fc; 20 g (10...3000 Hz) / -20...50 °C; 50 sweep cycles, 1 octave per minute, in 3 axes |
| EN 60068-2-6 Fc | 20 g (10...3000 Hz) / -20...50 °C |
| Shock resistance | EN 60068-2-27 Ea; 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C |
| EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C |
| Continuous shock resistance | EN 60068-2-27; 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
| EN 60068-2-27 | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
| Fast temperature change | EN 60068-2-14 Na; TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| EN 60068-2-14 Na | TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| Salt spray test | EN 60068-2-52 Kb; severity level 5 (4 test cycles) |
| EN 60068-2-52 Kb | severity level 5 (4 test cycles) |
| MTTF[years] [years] | 907 |
Mechanical data
| Weight[g] [g] | 696.2 |
| Housing | threaded type |
| Mounting | flush mountable |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 81 |
| Thread designation | M30 x 1.5 |
| Materials | threaded sleeve: stainless steel; sensing face: LCP natural; LED window: PEI; lock nuts: brass |
Displays / operating elements
| Display | switching status; 4 x 90° LED, yellow |
| switching status | 4 x 90° LED, yellow |
Accessories
| Items supplied | lock nuts: 2 |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Cable | 15 m, PUR; burning behaviour to ECE R118 rev. 2; 3 x 0.5 mm² |