Quick facts
| Availability | Confirmed on request |
| Category | All inductive sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can II5974 be shipped?
II5974 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up II5974 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for II5974 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for II5974, subject to availability and destination.
For a precise position monitoring on machines Flexible use thanks to large operating temperature range Very high repeatability Reliable transmission of the distance as linearised process value via IO-Link Normally closed / normally open and PNP/NPN adjustable via IO-Link
Specifications
Product characteristics
| Electrical design | PNP/NPN; (parameterisable) |
| Output function | normally open / normally closed; (selectable) |
| Communication interface | IO-Link |
| Housing | threaded type |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 65 |
Electrical data
| Operating voltage[V] [V] | 10...30 DC |
| Current consumption[mA] [mA] | < 15 |
| Protection class | III |
| Reverse polarity protection | yes |
Outputs
| Electrical design | PNP/NPN; (parameterisable) |
| Output function | normally open / normally closed; (selectable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 100 |
| Short-circuit protection | yes |
| Overload protection | yes |
Detection zone
| Switch point IO-Link[mm] [mm] | 4.3...21.5; (parameterisable) |
| Measuring range IO-Link[mm] [mm] | 2.3...23 |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.5 / copper: 0.4 |
| Hysteresis[% of Sr] [% of Sr] | 3...15 |
| Linearity error of analogue output[%] [%] | ± 2 %; (of the final value of the measuring range) |
| Repeatability analogue output[%] [%] | ± 1 %; (of the final value of the measuring range) |
| Temperature coefficient | ± 0,3 %/K; (of the final value of the measuring range) |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Multiple switching signal; Function; Process data variable; Function; Device diagnosis; Function; Teach channel |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Teach channel |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 3 |
| Supported DeviceIDs | default; 791 |
| default | 791 |
Operating conditions
| Ambient temperature[°C] [°C] | -40...85 |
| Protection | IP 65; IP 66; IP 67; IP 68; IP 69K |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V; EN 55011; class B |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| EN 55011 | class B |
| Vibration resistance | EN 60068-2-6 Fc; 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| EN 60068-2-6 Fc | 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| Shock resistance | EN 60068-2-27 Ea; 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| Continuous shock resistance | EN 60068-2-29 Eb; 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-29 Eb | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| Fast temperature change | EN 60068-2-14 Na; TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| EN 60068-2-14 Na | TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| MTTF[years] [years] | 664 |
| Embedded software included | yes |
| UL approval | Ta; -25...70 °C; Enclosure type; Type 1; power supply; Limited Voltage/Current; UL approval no.; A008; File number UL; E174191 |
| Ta | -25...70 °C |
| Enclosure type | Type 1 |
| power supply | Limited Voltage/Current |
| UL approval no. | A008 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 113.2 |
| Housing | threaded type |
| Mounting | non-flush mountable |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 65 |
| Thread designation | M30 x 1.5 |
| Materials | housing: brass white bronze coated; sensing face: PBT orange; LED window: PEI; lock nuts: brass white bronze coated |
Displays / operating elements
| Display | switching status; 4 x LED, yellow; SIO mode; output stage supplied with current; LED, yellow lights; IO-Link mode; target in measuring range; LED, yellow lights |
| switching status | 4 x LED, yellow |
| output stage supplied with current | LED, yellow lights |
| target in measuring range | LED, yellow lights |
Accessories
| Items supplied | lock nuts: 2 |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection - plug
| Connector | 1 x M12; coding: A |