| Availability | Confirmed on request |
| Category | All inductive sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can IGP200 be shipped?
IGP200 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up IGP200 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for IGP200 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for IGP200, subject to availability and destination.
For a precise position monitoring on machines Flexible use thanks to large operating temperature range Very high repeatability Reliable transmission of the distance as linearised process value via IO-Link Normally closed / normally open and PNP/NPN adjustable via IO-Link
Specifications
Product characteristics
| Electrical design | PNP/NPN; (parameterisable) |
| Output function | normally open / normally closed; (parameterisable) |
| Communication interface | IO-Link |
| Housing | threaded type |
| Dimensions[mm] [mm] | M18 x 1 / L = 60 |
Application
| Special feature | Magnetic-field immune |
| Magnetic-field immune | yes |
| Max. magnetic field immunity[mT] [mT] | 300 |
Electrical data
| Operating voltage[V] [V] | 10...30 DC |
| Current consumption[mA] [mA] | < 20 |
| Protection class | III |
| Reverse polarity protection | yes |
Outputs
| Electrical design | PNP/NPN; (parameterisable) |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 75 |
| Short-circuit protection | yes |
| Overload protection | yes |
Detection zone
| Switch point IO-Link[mm] [mm] | 1...4.85 |
| Measuring range IO-Link[mm] [mm] | 0.5...5 |
Accuracy / deviations
| Repeatability | < 20 µm |
| Resolution[µm] [µm] | 10 |
| Temperature drift | ± 3 µm/K |
| Linearity deviation | ± 50 µm |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 4.1.1; Measuring and Switching Sensor, 1 channel; Common - I&D; Identification and Diagnosis; Extension; Object detection, switches when value falls below the setpoint; Function; Locator; Function; ProductURI |
| Smart Sensor - SSP 4.1.1 | Measuring and Switching Sensor, 1 channel |
| Common - I&D | Identification and Diagnosis |
| Extension | Object detection, switches when value falls below the setpoint |
| Function | ProductURI |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 3.2 |
| Supported DeviceIDs | default; 1706 |
| default | 1706 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...70 |
| Protection | IP 65; IP 66; IP 67; IP 68; IP 69K |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V; EN 55011; class B |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| EN 55011 | class B |
| Vibration resistance | EN 60068-2-6 Fc; 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| EN 60068-2-6 Fc | 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| Shock resistance | EN 60068-2-27 Ea; 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| Continuous shock resistance | EN 60068-2-27 Eb; 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 Eb | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| Fast temperature change | EN 60068-2-14 Na; TA = -25 °C; TB = 70 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| EN 60068-2-14 Na | TA = -25 °C; TB = 70 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| MTTF[years] [years] | 1341 |
| Embedded software included | yes |
| UL approval | Ta; -25...70 °C; Enclosure type; Type 1; power supply; Limited Voltage/Current; UL approval no.; A005; File number UL; E174191 |
| Ta | -25...70 °C |
| Enclosure type | Type 1 |
| power supply | Limited Voltage/Current |
| UL approval no. | A005 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 73.5 |
| Housing | threaded type |
| Mounting | flush mountable |
| Dimensions[mm] [mm] | M18 x 1 / L = 60 |
| Thread designation | M18 x 1 |
| Materials | housing: stainless steel (316L/1.4404); sensing face: LCP white; LED window: PEI; lock nuts: stainless steel (316L/1.4404) |
| Tightening torque[Nm] [Nm] | 7 |
Displays / operating elements
| Display | switching status; 4 x LED, yellow; SIO mode; output stage supplied with current; LED, yellow lights; IO-Link mode; target in measuring range; LED, yellow lights |
| switching status | 4 x LED, yellow |
| output stage supplied with current | LED, yellow lights |
| target in measuring range | LED, yellow lights |
Accessories
| Items supplied | lock nuts: 2 |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection - plug
| Connector | 1 x M12; coding: A |