IFM IGC268
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | All inductive sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can IGC268 be shipped?
IGC268 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up IGC268 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for IGC268 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for IGC268, subject to availability and destination.
For use in machine tools and metalworking Resistant to oils and coolants Metal sensing face for heavy duty Clearly visible indication of the switching status
Specifications
Product characteristics
| Electrical design | NPN |
| Output function | normally open |
| Sensing range[mm] [mm] | 8 |
| Housing | threaded type |
| Dimensions[mm] [mm] | M18 x 1 / L = 60 |
Application
| Special feature | Drag chain suitability; Increased sensing range; Full-metal housing |
| Application | Use in machine tools, coolants and lubricants |
| Pressure rating | 20 bar; 2 MPa |
| 20 bar | 2 MPa |
| Note on pressure rating | sensing face |
Electrical data
| Operating voltage[V] [V] | 8.5...60 DC |
| Current consumption[mA] [mA] | < 10 |
| Protection class | III |
| Reverse polarity protection | yes |
Outputs
| Electrical design | NPN |
| Output function | normally open |
| Max. voltage drop switching output DC[V] [V] | 1.8 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 100 |
| Short-circuit protection | yes |
| Overload protection | yes |
Detection zone
| Sensing range[mm] [mm] | 8 |
| Real sensing range Sr[mm] [mm] | 8 ± 10 % |
| Operating distance[mm] [mm] | 0...6.48 |
| Increased sensing range | yes |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.6 / aluminium: 0.5 / copper: 0.2 |
| Hysteresis[% of Sr] [% of Sr] | 3...15 |
| Switch point drift[% of Sr] [% of Sr] | -10...10 |
Operating conditions
| Ambient temperature[°C] [°C] | -40...85 |
| Protection | IP 65; IP 66; IP 67; IP 68; IP 69K; (IP68 specification: minimum pressure of 0.5 bar for 7 days of continuous immersion) |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V; EN 55011; class B |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| EN 55011 | class B |
| Vibration resistance | EN 60068-2-6 Fc; 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| EN 60068-2-6 Fc | 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| Shock resistance | EN 60068-2-27 Ea; 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| Continuous shock resistance | EN 60068-2-27; 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| Fast temperature change | EN 60068-2-14 Na; TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| EN 60068-2-14 Na | TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| Salt spray test | EN 60068-2-52 Kb; severity level 5 (4 test cycles) |
| EN 60068-2-52 Kb | severity level 5 (4 test cycles) |
| UL approval | Ta; -25...75 °C; Enclosure type; Type 1; power supply; Class 2; UL approval no.; A058; File number UL; E174191 |
| Ta | -25...75 °C |
| Enclosure type | Type 1 |
| power supply | Class 2 |
| UL approval no. | A058 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 120.55 |
| Housing | threaded type |
| Mounting | flush mountable |
| Dimensions[mm] [mm] | M18 x 1 / L = 60 |
| Thread designation | M18 x 1 |
| Materials | stainless steel (316L/1.4404); sensing face: stainless steel (316L/1.4404); LED window: PEI; lock nuts: stainless steel (316L/1.4404) |
| Tightening torque[Nm] [Nm] | 50 |
| Drag chain suitability | bending radius for flexible use; min. 10 x cable diameter; bending cycles; > 5 Mio. |
| bending radius for flexible use | min. 10 x cable diameter |
| bending cycles | > 5 Mio. |
| Full-metal housing | yes |
Displays / operating elements
| Display | switching status; LED, yellow |
| switching status | LED, yellow |
Accessories
| Items supplied | lock nuts: 2 |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Cable | 2 m, PUR, Ø 4.9 mm; burning behaviour to ECE R118 rev. 2; 3 x 0.5 mm² |