IFM IF0312
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | All inductive sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can IF0312 be shipped?
IF0312 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up IF0312 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for IF0312 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for IF0312, subject to availability and destination.
With combined AC/DC output stage Large operating voltage range Two-wire technology Long sensing range for high uptime Robust metal housing for use in harsh industrial environments
Specifications
Product characteristics
| Output function | normally open |
| Sensing range[mm] [mm] | 7 |
| Housing | threaded type |
| Dimensions[mm] [mm] | M12 x 1 / L = 62 |
Application
| Special feature | Increased sensing range |
Electrical data
| Frequency AC[Hz] [Hz] | 47...63 |
| Operating voltage[V] [V] | 20...140 AC / 10...140 DC |
| Protection class | I |
| Reverse polarity protection | no |
Outputs
| Output function | normally open |
| Max. voltage drop switching output DC[V] [V] | 5 |
| Max. voltage drop switching output AC[V] [V] | 5 |
| Minimum load current[mA] [mA] | 5 |
| Max. leakage current[mA] [mA] | 0.8 |
| Permanent current rating of switching output AC[mA] [mA] | 200 |
| Permanent current rating of switching output DC[mA] [mA] | 200 |
| Short-time current rating of switching output[mA] [mA] | 900; (20 ms / 0,5 Hz) |
| Switching frequency AC[Hz] [Hz] | 25 |
| Switching frequency DC[Hz] [Hz] | 90 |
| Short-circuit proof | no |
| Overload protection | no |
Detection zone
| Sensing range[mm] [mm] | 7 |
| Operating distance[mm] [mm] | 0...5.7 |
| Increased sensing range | yes |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2 |
| Hysteresis[% of Sr] [% of Sr] | 3...15 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...70 |
| Protection | IP 67 |
Tests / approvals
| EMC | EN 60947-5-2; EN 55011; class B |
| EN 55011 | class B |
| MTTF[years] [years] | 1684 |
| UL approval | Ta; 0...40 °C; Enclosure type; Type 1; File number UL; E174191 |
| Ta | 0...40 °C |
| Enclosure type | Type 1 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 30.1 |
| Housing | threaded type |
| Mounting | non-flush mountable |
| Dimensions[mm] [mm] | M12 x 1 / L = 62 |
| Thread designation | M12 x 1 |
| Materials | brass white bronze coated; PBT |
Displays / operating elements
| Display | switching status; 1 x LED, red |
| switching status | 1 x LED, red |
Electrical connection
| Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
Accessories
| Items supplied | lock nuts: 2 |
Remarks
| Remarks | Recommendation: Check the safe functioning of the unit after a short circuit. |
| Pack quantity | 1 pcs. |
Electrical connection - plug
| Connector | 1 x 1/2"; coding: C |