IFM GI761S
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Fail-safe inductive sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can GI761S be shipped?
GI761S is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up GI761S in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for GI761S and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for GI761S, subject to availability and destination.
Certified to the following standards: EN 60947-5-3, IEC 61508 and ISO 13849 Connection to safety PLC, safe AS-i modules or safe evaluation units Ensuring operator and machine safety Stainless steel sensing face High protection rating
Specifications
Product characteristics
| Electrical design | PNP |
| Enable zone[mm] [mm] | 0...6 |
| Housing | threaded type |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 65 |
Application
| Special feature | Gold-plated contacts; Full-metal housing |
| Type of operation | permanent operation |
| Safety-related sub-function | safe state when properly undamped |
| Application | Use in mobile and harsh applications |
Electrical data
| Operating voltage[V] [V] | 9...32 DC |
| Rated insulation voltage[V] [V] | 60 |
| Current consumption[mA] [mA] | < 10; (24 V) |
| Protection class | III |
| Reverse polarity protection | yes |
| Max. power-on delay time[ms] [ms] | 500 |
Outputs
| Electrical design | PNP |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Number of OSSD outputs | 2 |
| Max. current load per OSSD output[mA] [mA] | 50 |
| Output data | Interface type C class 1 |
| Output voltage at 24 V | compatible with EN 61131-2 inputs type 1, 2 |
| Short-circuit protection | yes |
| Overload protection | yes |
| Max. capacitive load CL_max[nF] [nF] | 20 |
Detection zone
| Enable zone[mm] [mm] | 0...6 |
| Safe switch-off distance sAs (sar)[mm] [mm] | 18 |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.8 / aluminium: 0.6 / copper: 0.3 |
Response times
| Response time when approaching the enable zone, turn-on time (ton)[ms] [ms] | 20 |
| Response time to safety request, turn-off time (toff)[ms] [ms] | 20 |
| Risk time / error handling time (toff max)[ms] [ms] | 100; (at ambient temperature <-25 °C: 250 ms; flush mounting with a single stainless steel fixing nut: 250 ms) |
Operating conditions
| Ambient temperature[°C] [°C] | -40...85 |
| Max. height above sea level[m] [m] | 3000 |
| Ionising radiation | not permissible |
| Protection | IP 65; IP 66; IP 67; IP 68; IP 69K |
Tests / approvals
| EMC | industrial environments; EN 60947-5-3; EN 61000-4-2 ESD; 6 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 20 V/m 80...1000 MHz; EN 61000-4-3 HF radiated; 10 V/m 1,4...2,0 GHz / 3 V/m 2,0...6,0 GHz; EN 61000-4-4 Burst; 2 kV; EN 61000-4-5 Surge; 2 kV; EN 61000-4-6 HF conducted; 10 V; EN 61000-4-8; 30 A/m 50/60 Hz / 1000 A/m 0 Hz; EN 55011; class B; mobile applications; only for operation with central load-dump suppression (58 V) / not for active operation during motor start phase in 12 V systems; ISO 10605 ESD; 8 kV CD / 15 kV AD; ISO 11452-2, ISO 11452-5 radiated immunity; 100 V/m 400...3000 MHz; ISO 7637-2, ISO 16750-2 conducted immunity; 12 V / 24 V; pulse; 1 2a 2b 3a 3b 4 5b; severity level; III III III III III III 58V; failure criterion; B A B A A C/B A/C; EN 55025; class 3 |
| EN 61000-4-2 ESD | 6 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m 1,4...2,0 GHz / 3 V/m 2,0...6,0 GHz |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-5 Surge | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| EN 61000-4-8 | 30 A/m 50/60 Hz / 1000 A/m 0 Hz |
| EN 55011 | class B |
| mobile applications | only for operation with central load-dump suppression (58 V) / not for active operation during motor start phase in 12 V systems |
| ISO 10605 ESD | 8 kV CD / 15 kV AD |
| ISO 11452-2, ISO 11452-5 radiated immunity | 100 V/m 400...3000 MHz |
| ISO 7637-2, ISO 16750-2 conducted immunity | 12 V / 24 V |
| pulse | 1 2a 2b 3a 3b 4 5b |
| severity level | III III III III III III 58V |
| failure criterion | B A B A A C/B A/C |
| EN 55025 | class 3 |
| Shock resistance | EN 60068-2-27 Ea; 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 Ea | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| Continuous shock resistance | EN 60068-2-27 Ea; 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| Fast temperature change | EN 60068-2-14 Na; TA = -40°C; TB = 85°C; t1 = 45 min; t2 = 10 s 100 cycles |
| EN 60068-2-14 Na | TA = -40°C; TB = 85°C; t1 = 45 min; t2 = 10 s 100 cycles |
| Vibration resistance | EN 60068-2-6 Fc; 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes; EN 60068-2-64 Fh; 5.9 g RMS / effective acceleration for chassis mounting; ISO 19014-3; 5.7 g RMS / effective acceleration |
| EN 60068-2-6 Fc | 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| EN 60068-2-64 Fh | 5.9 g RMS / effective acceleration for chassis mounting |
| ISO 19014-3 | 5.7 g RMS / effective acceleration |
| Salt spray test | EN 60068-2-52 Kb; severity level 5 (4 test cycles) |
| EN 60068-2-52 Kb | severity level 5 (4 test cycles) |
Safety classification
| Complies with the requirements | ISO 13849-1 category 2, PL d; IEC 61508 SIL 2, HFT 0, SC 2 |
| Mission time TM[h] [h] | ≤ 87600 |
| Mission time TM (additional indication) | industrial environments Temperature range -25...70 °C ≤ 175200 |
| PFH[1/h] [1/h] | < 1,5E-07 |
Mechanical data
| Weight[g] [g] | 134.1 |
| Housing | threaded type |
| Mounting | flush mountable |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 65 |
| Thread designation | M30 x 1.5 |
| Materials | threaded sleeve: stainless steel (316L/1.4404); sensing face: stainless steel (316L/1.4404); LED window: PEI; LED Sealing: PU; lock nuts: stainless steel (316L/1.4404) |
| Tightening torque[Nm] [Nm] | 70 |
| Full-metal housing | yes |
Displays / operating elements
| Display | Display switching status; 4 LED, yellow |
| Display switching status | 4 LED, yellow |
Accessories
| Items supplied | lock nuts: 2 |
Remarks
| Remarks | meets the environmental and EMC requirements for operation in agricultural and forestry machinery, earthworks and construction machines as well as in industrial trucks; can be used in applications up to SIL 2 in accordance with IEC 62061, MPL d in accordance with ISO 19014-3 and Ag PL d in accordance with ISO 25119; Unless stated otherwise, all data refer to the reference target plate to IEC 60947-5-2 over the whole temperature range.; (FE360 = ST37-2K) 30x30x1 mm; the correction factors apply to an ambient temperature of 20°C; do not use a correction factor for the safe switch-off distance sAs/(sar) |
| Pack quantity | 1 pcs. |
Electrical connection - plug
| Connector | 1 x M12; coding: A; Contacts: gold-plated |