IFM E84016
Quick facts
| Availability | Confirmed on request |
| Category | 24 V DC power supplies |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can E84016 be shipped?
E84016 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up E84016 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for E84016 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for E84016, subject to availability and destination.
For the regulated power supply for controllers, sensors, actuators, and industrial electronics Low power loss thanks to high efficiency High mains buffering time Possibility to shut down the device via pulse pick-up High power reserves
Specifications
Electrical data
| Frequency AC[Hz] [Hz] | 47...64 |
| Nominal voltage AC[V] [V] | < 230 |
| Input voltage range AC[V] [V] | 100...240; (-15 % / +10 %) |
| Output voltage DC[V] [V] | 24...28 |
| Protection class | I; (IEC 61140) |
| Overvoltage protection | yes; (< 32 DC) |
| Output voltage[V] [V] | adjustable; output voltage to SELV, PELV |
| Max. output current at min. output voltage[A] [A] | 40 |
| Max. output current at max. output voltage[A] [A] | 34.3 |
| Max. output current peak at min. output voltage[A] [A] | 60 |
| Max. output current peak at max. output voltage[A] [A] | 51.5 |
| Output power (permanent)[W] [W] | 960 |
| Output power (peak)[W] [W] | 1440 |
| Note on output power (peak)[W] [W] | if consumption > 4 s the power is automatically reduced to the output power |
| Power factor (nominal voltage 120 V AC / 60 Hz) | 0.99 |
| Power factor (nominal voltage 230 V AC / 50 Hz) | 0.99 |
| Power reserve[%] [%] | 50 |
| Number of output circuits | 1 |
| Max. residual ripple[mV] [mV] | 100 |
| Switch-on peak current (nominal voltage 120 V AC / 60 Hz)[A] [A] | 17 |
| Switch-on peak current (nominal voltage 230 V AC / 50 Hz)[A] [A] | 11 |
| Inrush current limitation | yes |
| Efficiency (nominal voltage 120 V AC / 60 Hz)[%] [%] | 93.6 |
| Efficiency (nominal voltage 230 V AC / 50 Hz)[%] [%] | 94.6 |
| External input protection | ≥ B-16 A / ≥ C-16 A |
| Derating[W/K] [W/K] | 24 (60...70 °C) |
| Mains buffering time (nominal voltage 120 V AC / 60 Hz)[ms] [ms] | 27 |
| Mains buffering time (nominal voltage 230 V AC / 50 Hz)[ms] [ms] | 27 |
| Input current (nominal voltage 120 V AC / 60 Hz)[A] [A] | 8.6 |
| Input current (nominal voltage 230 V AC / 50 Hz)[A] [A] | 4.5 |
| Power loss (nominal voltage 120 V AC / 60 Hz)[W] [W] | 65.6 |
| Power loss (nominal voltage 230 V AC / 50 Hz)[W] [W] | 54.8 |
| Back feeding protection[V] [V] | 35 |
Outputs
| Short-circuit proof | yes |
| Overload protection | yes |
| Overload performance | Hiccup Mode; In the event of overload / short circuit, the output alternately supplies continuous power for 2 s and then switches off for 17 s. |
| Type DC-OK signal | relay output |
| Reliability of the DC OK signal | 60 V DC (0.3 A) / 30 V DC (1 A) / 30 V AC (0.5 A) |
Operating conditions
| Ambient temperature[°C] [°C] | -25...70 |
| Note on ambient temperature | observe the free space for convection (see operating instructions) |
| Storage temperature[°C] [°C] | -40...85 |
| Max. relative air humidity[%] [%] | 95; (IEC 60068-2-30) |
| Protection | IP 20; (EN 60529) |
| Pollution degree | 2; (IEC 62103: conductive soiling not permitted) |
Tests / approvals
| EMC | EN 61000-6-1; EN 61000-6-2; EN 61000-6-3; EN 61000-6-4; EN 61000-3-2; Class A |
| EN 61000-3-2 | Class A |
| Vibration resistance | IEC 60068-2-6; ±1,6 mm 2...17,8 Hz / 1 g 17,8...500 Hz |
| IEC 60068-2-6 | ±1,6 mm 2...17,8 Hz / 1 g 17,8...500 Hz |
| Shock resistance | IEC 60068-2-27; 15 g 6 ms / 10 g 11 ms |
| IEC 60068-2-27 | 15 g 6 ms / 10 g 11 ms |
| MTTF[years] [years] | 55 |
| Power Factor Correction (PFC) | met |
Mechanical data
| Weight[g] [g] | 2044.5 |
| Housing | rectangular |
| Type of mounting | mounting on DIN rail; (TH35 (EN 60715)) |
| Dimensions[mm] [mm] | 124 x 125 x 132.6 |
| Materials | housing: steel sheet |
Displays / operating elements
| Display | DC ok; 1 x LED; overload; 1 x LED |
| DC ok | 1 x LED |
| overload | 1 x LED |
Remarks
| Remarks | Series connection of outputs only applies to identical units up to max. 150 V DC overall voltage |
| Pack quantity | 1 pcs. |