IFM DP1615
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | IO-Link converter |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can DP1615 be shipped?
DP1615 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up DP1615 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for DP1615 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for DP1615, subject to availability and destination.
Compact housing with high protection rating For controlling 24V RGBW LED strips User-friendly communication and parameterisation via IO-Link Control via IO-Link or digital inputs
Specifications
Electrical data
| Operating voltage[V] [V] | 21.6...26.4 DC; (to SELV/PELV) |
| Nominal voltage DC[V] [V] | 24 |
| Current consumption[mA] [mA] | < 1230 |
| Max. current load total[A] [A] | 1.2 |
Inputs / outputs
| Number of inputs and outputs | Number of digital inputs: 3; Number of digital outputs: 4 |
Inputs
| Number of digital inputs | 3 |
| Switching level high[V] [V] | 11...26.4 |
| Switching level low[V] [V] | 0...5 |
Outputs
| Output signal | switching signal |
| Number of digital outputs | 4 |
| Max. current load per output[mA] [mA] | 400; 640; (400 mA: red; green; blue; 640 mA: white) |
| Max. current load outputs total[A] [A] | 1.2 |
| Short-circuit proof | yes |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Common - I&D; Identification and Diagnosis |
| Common - I&D | Identification and Diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 4.2 |
| Supported DeviceIDs | default; 1474 |
| default | 1474 |
| Note | For further information please see the IODD PDF file under "Downloads" |
Operating conditions
| Ambient temperature[°C] [°C] | -25...60 |
| Storage temperature[°C] [°C] | -25...60 |
| Max. relative air humidity[%] [%] | 90; (linearly decreasing to 50 % (40 °C); non condensing) |
| Max. height above sea level[m] [m] | 2000 |
| Protection | IP 65; IP 67 |
| Pollution degree | 2 |
Tests / approvals
| EMC | IEC61131-2 |
| MTTF[years] [years] | 291 |
Mechanical data
| Weight[g] [g] | 130.2 |
| Weight (without accessories and packaging)[g] [g] | 0.001 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 99.1 x 50 x 31 |
| Materials | housing: PA; cover: PA; Sealing cover: TPE |
| Sealing material | FKM |
Displays / operating elements
| Display | operation; LED, green |
| operation | LED, green |
Accessories
| Accessories (optional) | mounting clip, E89209 |
Remarks
| Remarks | Please observe the permissible voltage ranges of the connected devices, as these may differ from the IO-Link specification.; For further information please see the operating instructions.; the device complies with overvoltage category II |
| Pack quantity | 1 pcs. |
Electrical connection - socket
| Connector | 1 x M12; coding: A; Sealing: FKM |
Electrical connection - plug
| Connector | 1 x M12; coding: A |