IFM DN4218
Quick facts
| Availability | Confirmed on request |
| Category | Field power supplies |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can DN4218 be shipped?
DN4218 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up DN4218 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for DN4218 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for DN4218, subject to availability and destination.
Protection of the wiring via configurable electronic circuit breakers Installation without control cabinet Additional diagnostics by measuring current, voltage and mains quality as well as counting operating hours Energy-efficient generation of extra-low voltage without power loss Output voltage, load currents, output circuit states and trigger cause are communicated via IO-Link Switching the output circuits on and off as well as resetting the circuit breakers is possible via IO-Link
Specifications
Electrical data
| Nominal voltage AC[V] [V] | 230 |
| Nominal voltage DC[V] [V] | 300 |
| Nominal frequency AC[Hz] [Hz] | 50...60 |
| Input voltage DC[V] [V] | 110...300 |
| Input voltage range AC[V] [V] | 100...240; (-15 % / +10 %) |
| Output voltage DC[V] [V] | 24...28 |
| Protection class | I |
| Max. power-on delay time[ms] [ms] | 2000 |
| Max. output current at min. output voltage[A] [A] | 12.5 |
| Max. output current at max. output voltage[A] [A] | 10.7 |
| Output power (permanent)[W] [W] | 300 |
| Output power (peak)[W] [W] | 600 |
| Power factor (nominal voltage 230 V AC / 50 Hz) | 0.97 |
| Number of output circuits | 4 |
| Efficiency (nominal voltage 120 V AC / 60 Hz)[%] [%] | 94.3 |
| Efficiency (nominal voltage 230 V AC / 50 Hz)[%] [%] | 95.7 |
| Mains buffering time (nominal voltage 120 V AC / 60 Hz)[ms] [ms] | 44 |
| Mains buffering time (nominal voltage 230 V AC / 50 Hz)[ms] [ms] | 44 |
| Input current (nominal voltage 120 V AC / 60 Hz)[A] [A] | 3.2 |
| Input current (nominal voltage 230 V AC / 50 Hz)[A] [A] | 1.68 |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM3 (230,4 kBaud) |
| IO-Link revision | 1.1 |
| Profiles | Common - I&D; Identification and Diagnosis |
| Common - I&D | Identification and Diagnosis |
| SIO mode | yes |
| Min. process cycle time[ms] [ms] | 2 |
| Supported DeviceIDs | default; 1535 |
| default | 1535 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...55 |
| Note on ambient temperature | the derating of the current load indicated in the operating instructions is to be taken into account at the following ambient temperature: 70 °C |
| Storage temperature[°C] [°C] | -40...85 |
| Max. relative air humidity[%] [%] | 95; (relative humidity) |
| Max. height above sea level[m] [m] | 5000 |
| Protection | IP 65; IP 67 |
| Pollution degree | 3 |
Tests / approvals
| EMC | EN 61000-4-2 CD; 8 kV / failure criterion A; EN 61000-4-2 AD; 15 kV / failure criterion A; EN 61000-4-3; 80 Mhz...2.7 GHz / 20 V/m failure criterion A; EN 61000-4-3; 2.7 GHz...6 GHz kV / 10 V/m failure criterion A; EN 61000-4-8; 50 / 60 Hz / 30 A/m failure criterion A; EN 61000-4-4 Burst; 4 kV / failure criterion A; EN 61000-4-5 Surge; 2 kV Lx / Ly / failure criterion A; EN 61000-4-5 Surge; 4 kV L / PE / failure criterion A; EN 61000-4-5 Surge; 1 kV + / - / failure criterion A; EN 61000-4-5 Surge; 1 kV + - / PE / failure criterion A; EN 61000-4-5 Surge; 1 kV + - / PE / failure criterion A; EN 61000-4-5 Surge; 1 kV DC-OK / PE / failure criterion A; EN 61000-4-6; 0.15...80 MHz / 20 V failure criterion A; EN 61000-4-11; 0 V up to 1 cycle / failure criterion A; EN 61000-4-11; 40 % of V / 200 ms failure criterion A; EN 61000-4-11; 70 % of V / 500 ms failure criterion A; EN 61000-4-11; 0 V / 5000 ms failure criterion C; VDE 0160; 1550 V / 1.3 ms failure criterion A; EN 55032; Class B; EN 55032; Class B; EN 55011; Class B; EN 61000-3-2; EN 61000-3-3 |
| EN 61000-4-2 CD | 8 kV / failure criterion A |
| EN 61000-4-2 AD | 15 kV / failure criterion A |
| EN 61000-4-3 | 2.7 GHz...6 GHz kV / 10 V/m failure criterion A |
| EN 61000-4-8 | 50 / 60 Hz / 30 A/m failure criterion A |
| EN 61000-4-4 Burst | 4 kV / failure criterion A |
| EN 61000-4-5 Surge | 1 kV DC-OK / PE / failure criterion A |
| EN 61000-4-6 | 0.15...80 MHz / 20 V failure criterion A |
| EN 61000-4-11 | 0 V / 5000 ms failure criterion C |
| VDE 0160 | 1550 V / 1.3 ms failure criterion A |
| EN 55032 | Class B |
| EN 55011 | Class B |
| Continuous shock resistance | IEC 60068-2-27; 30 g 6 ms / 20 g 11 ms |
| IEC 60068-2-27 | 30 g 6 ms / 20 g 11 ms |
| Vibration resistance | IEC 600068-2-6; 2...17.8 Hz ± 1.6mm / 17.8...500 Hz 2 g |
| IEC 600068-2-6 | 2...17.8 Hz ± 1.6mm / 17.8...500 Hz 2 g |
| MTTF[years] [years] | 31 |
Mechanical data
| Weight[g] [g] | 1524.5 |
| Housing | rectangular |
| Type of mounting | backplane mounting |
| Dimensions[mm] [mm] | 199.7 x 178 x 59.5 |
| Materials | housing: aluminium alloy; housing cap: PC; screws: steel bronzed |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection - IO-Link
| Connector | 1 x M12; coding: A; Locking: brass |
Electrical connection - Output voltage
| Connector | 2 x M12; coding: A; Locking: brass |
Electrical connection - power supply
| Connector | 1 x 7/8"; Locking: brass |