AvailabilityConfirmed on request
CategoryField power supplies
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can DN4218 be shipped?

DN4218 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up DN4218 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for DN4218 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for DN4218, subject to availability and destination.

Protection of the wiring via configurable electronic circuit breakers Installation without control cabinet Additional diagnostics by measuring current, voltage and mains quality as well as counting operating hours Energy-efficient generation of extra-low voltage without power loss Output voltage, load currents, output circuit states and trigger cause are communicated via IO-Link Switching the output circuits on and off as well as resetting the circuit breakers is possible via IO-Link

Specifications

Electrical data

Nominal voltage AC[V] [V]230
Nominal voltage DC[V] [V]300
Nominal frequency AC[Hz] [Hz]50...60
Input voltage DC[V] [V]110...300
Input voltage range AC[V] [V]100...240; (-15 % / +10 %)
Output voltage DC[V] [V]24...28
Protection classI
Max. power-on delay time[ms] [ms]2000
Max. output current at min. output voltage[A] [A]12.5
Max. output current at max. output voltage[A] [A]10.7
Output power (permanent)[W] [W]300
Output power (peak)[W] [W]600
Power factor (nominal voltage 230 V AC / 50 Hz)0.97
Number of output circuits4
Efficiency (nominal voltage 120 V AC / 60 Hz)[%] [%]94.3
Efficiency (nominal voltage 230 V AC / 50 Hz)[%] [%]95.7
Mains buffering time (nominal voltage 120 V AC / 60 Hz)[ms] [ms]44
Mains buffering time (nominal voltage 230 V AC / 50 Hz)[ms] [ms]44
Input current (nominal voltage 120 V AC / 60 Hz)[A] [A]3.2
Input current (nominal voltage 230 V AC / 50 Hz)[A] [A]1.68

Interfaces

Communication interfaceIO-Link
Transmission typeCOM3 (230,4 kBaud)
IO-Link revision1.1
ProfilesCommon - I&D; Identification and Diagnosis
Common - I&DIdentification and Diagnosis
SIO modeyes
Min. process cycle time[ms] [ms]2
Supported DeviceIDsdefault; 1535
default1535

Operating conditions

Ambient temperature[°C] [°C]-25...55
Note on ambient temperaturethe derating of the current load indicated in the operating instructions is to be taken into account at the following ambient temperature: 70 °C
Storage temperature[°C] [°C]-40...85
Max. relative air humidity[%] [%]95; (relative humidity)
Max. height above sea level[m] [m]5000
ProtectionIP 65; IP 67
Pollution degree3

Tests / approvals

EMCEN 61000-4-2 CD; 8 kV / failure criterion A; EN 61000-4-2 AD; 15 kV / failure criterion A; EN 61000-4-3; 80 Mhz...2.7 GHz / 20 V/m failure criterion A; EN 61000-4-3; 2.7 GHz...6 GHz kV / 10 V/m failure criterion A; EN 61000-4-8; 50 / 60 Hz / 30 A/m failure criterion A; EN 61000-4-4 Burst; 4 kV / failure criterion A; EN 61000-4-5 Surge; 2 kV Lx / Ly / failure criterion A; EN 61000-4-5 Surge; 4 kV L / PE / failure criterion A; EN 61000-4-5 Surge; 1 kV + / - / failure criterion A; EN 61000-4-5 Surge; 1 kV + - / PE / failure criterion A; EN 61000-4-5 Surge; 1 kV + - / PE / failure criterion A; EN 61000-4-5 Surge; 1 kV DC-OK / PE / failure criterion A; EN 61000-4-6; 0.15...80 MHz / 20 V failure criterion A; EN 61000-4-11; 0 V up to 1 cycle / failure criterion A; EN 61000-4-11; 40 % of V / 200 ms failure criterion A; EN 61000-4-11; 70 % of V / 500 ms failure criterion A; EN 61000-4-11; 0 V / 5000 ms failure criterion C; VDE 0160; 1550 V / 1.3 ms failure criterion A; EN 55032; Class B; EN 55032; Class B; EN 55011; Class B; EN 61000-3-2; EN 61000-3-3
EN 61000-4-2 CD8 kV / failure criterion A
EN 61000-4-2 AD15 kV / failure criterion A
EN 61000-4-32.7 GHz...6 GHz kV / 10 V/m failure criterion A
EN 61000-4-850 / 60 Hz / 30 A/m failure criterion A
EN 61000-4-4 Burst4 kV / failure criterion A
EN 61000-4-5 Surge1 kV DC-OK / PE / failure criterion A
EN 61000-4-60.15...80 MHz / 20 V failure criterion A
EN 61000-4-110 V / 5000 ms failure criterion C
VDE 01601550 V / 1.3 ms failure criterion A
EN 55032Class B
EN 55011Class B
Continuous shock resistanceIEC 60068-2-27; 30 g 6 ms / 20 g 11 ms
IEC 60068-2-2730 g 6 ms / 20 g 11 ms
Vibration resistanceIEC 600068-2-6; 2...17.8 Hz ± 1.6mm / 17.8...500 Hz 2 g
IEC 600068-2-62...17.8 Hz ± 1.6mm / 17.8...500 Hz 2 g
MTTF[years] [years]31

Mechanical data

Weight[g] [g]1524.5
Housingrectangular
Type of mountingbackplane mounting
Dimensions[mm] [mm]199.7 x 178 x 59.5
Materialshousing: aluminium alloy; housing cap: PC; screws: steel bronzed

Remarks

Pack quantity1 pcs.

Electrical connection - IO-Link

Connector1 x M12; coding: A; Locking: brass

Electrical connection - Output voltage

Connector2 x M12; coding: A; Locking: brass

Electrical connection - power supply

Connector1 x 7/8"; Locking: brass
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More IFM parts

IFM O8H205Available on requestIFM O8H205
MPN: O8H205 · IFM
Price on request
Request a quote
IFM O8H206Available on requestIFM O8H206
MPN: O8H206 · IFM
Price on request
Request a quote
IFM O8H207Available on requestIFM O8H207
MPN: O8H207 · IFM
Price on request
Request a quote
IFM O8H202Available on requestIFM O8H202
MPN: O8H202 · IFM
Price on request
Request a quote