IFM DL3003
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | 2-channel threshold relays |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can DL3003 be shipped?
DL3003 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up DL3003 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for DL3003 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for DL3003, subject to availability and destination.
For the reliable limit monitoring of flow, pressure, temperature, or level With two analogue inputs Possibility of calculating a new value based on the two input values Various configurable monitoring functions Monitoring data is provided via two relays and transistor outputs Easy parameter setting and process value output via IO-Link
Specifications
Product characteristics
| Communication interface | IO-Link |
| Housing | rectangular |
| Dimensions[mm] [mm] | 126 x 50 x 112.4 |
Application
| Design | housing for DIN rail mounting |
| Application | 2-channel threshold relay for analogue standard signals |
Electrical data
| Operating voltage[V] [V] | 110...240 AC / 18...30 DC; (tolerance AC operation: -20 % / +10 %) |
| Nominal voltage AC[V] [V] | 110...240 |
| Nominal voltage DC[V] [V] | 24 |
| Nominal frequency AC[Hz] [Hz] | 50...60 |
| Current consumption[mA] [mA] | AC operation: max. 8 A (including maximum AC supply for additional devices ) |
| Max. power consumption DC[W] [W] | 9 |
| Overvoltage category | II |
| Auxiliary energy for sensors DC[V] [V] | 16.5...27.7; (Short-circuit proof; DC operation: ≤ 200 mA; AC operation: ≤ 150 mA) |
Inputs / outputs
| Number of inputs and outputs | Number of analogue inputs: 2; Number of digital outputs: 2; Number of analogue outputs: 1; Number of relay outputs: 2 |
Inputs
| Number of analogue inputs | 2; (configurable) |
| Analogue input (current)[mA] [mA] | 0...20 |
| Input resistance[Ω] [Ω] | 300 |
| Analogue input (voltage)[V] [V] | 0...10 |
| Input resistance[kΩ] [kΩ] | 25 |
| Resolution of analogue input | 12 Bit |
Outputs
| Number of digital outputs | 2 |
| Number of relay outputs | 2; (changeover contact) |
| Number of analogue outputs | 1 |
| Circuit | PNP |
| Max. current load per output[mA] [mA] | 10 |
| Short-circuit proof | yes |
| Electrically separated | no |
| Minimum load current[mA] [mA] | 10; (> 12 V) |
| Contact rating | 6 A; (max. 240 V AC / 30 V DC see diagram:: Contact rating; B300: 6000 cycles) |
| Switching frequency AC[Hz] [Hz] | < 2 |
| Switching frequency DC[Hz] [Hz] | < 2 |
| Analogue current output[mA] [mA] | 4...20; (max.. 20,5 mA) |
| Max. load[Ω] [Ω] | 600; (300 Ω: Operating voltage < 24 V DC) |
Accuracy / deviations
| Accuracy | ± 0.75; (% of the final value < 45 °C; including analogue input accuracy) |
| Temperature coefficient[% of the span / 10 K] [% of the span / 10 K] | ± 0,1; (> 45 °C) |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 4.1.2; Measuring and Switching Sensor, 2 channel; Common - I&D; Identification and Diagnosis; Extension; Sensor control; Extension; Quantity detection, switches when value exceeds the setpoint; Function; Locator; Function; ProductURI |
| Smart Sensor - SSP 4.1.2 | Measuring and Switching Sensor, 2 channel |
| Common - I&D | Identification and Diagnosis |
| Extension | Quantity detection, switches when value exceeds the setpoint |
| Function | ProductURI |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 4.9 |
| Supported DeviceIDs | default; 1583 |
| default | 1583 |
Operating conditions
| Ambient temperature[°C] [°C] | -40...60 |
| Note on ambient temperature | 110V AC operation: -25...60 °C; 2000...3000 m: max. 58 °C; 3000...4000 m: max. 56 °C; Contact rating relay output: B300 max. 50 °C |
| Storage temperature[°C] [°C] | -40...85 |
| Max. relative air humidity[%] [%] | 80; (31 °C; linearly decreasing to 50 % (40 °C)) |
| Max. height above sea level[m] [m] | 4000 |
| Protection | IP 20; (when mounted) |
| Protection rating terminals | IP 20 |
| Pollution degree | 2 |
Tests / approvals
| EMC | EN 61000-6-2; EN 61000-6-8 |
| Electrical safety | EN 61010-1; EN 61010-2-201 |
| MTTF[years] [years] | 150 |
| UL approval | Ta; 60 °C; Enclosure type; open Type; File number UL; E191692 |
| Ta | 60 °C |
| Enclosure type | open Type |
| File number UL | E191692 |
Mechanical data
| Weight[g] [g] | 338.6 |
| Housing | rectangular |
| Type of mounting | mounting on DIN rail; (TH35 (EN 60715)) |
| Dimensions[mm] [mm] | 126 x 50 x 112.4 |
| Materials | housing: plastics |
Displays / operating elements
| Display | 1x OLED display, 128 x 64 pixels luminous; switching status; 2x LED, yellow; operation; 1x LED, green/red |
| switching status | 2x LED, yellow |
| operation | 1x LED, green/red |
| Teach function | yes |
Accessories
| Items supplied | cage clamps: 9 |
Remarks
| Remarks | For information about installation and operation please see the operating instructions. |
| Pack quantity | 1 pcs. |
Electrical connection
| cage clamps | ...2.5 mm² |