Available on request

IFM CR413S

MPN: CR413S · Brand: IFM
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryControllers for use in cabins and control cabinets
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can CR413S be shipped?

CR413S is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up CR413S in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for CR413S and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for CR413S, subject to availability and destination.

Freely programmable to IEC 61131-3 with CODESYS 3.5 High-performance CAN interface for various communication tasks Multifunctional inputs and current-controlled outputs ensure maximum adaptability Can be used as a safety controller up to SIL2/PL d when combined with a TÜV-certified software package

Specifications

Product characteristics

Total number of inputs16
Total number of outputs16
Communication interfaceCAN; Ethernet
ProtectionIP 20

Electrical data

Operating voltage[V] [V]8...32 DC
Nominal voltage DC[V] [V]12 / 24
Power consumption[W] [W]4; (VBB30)
Reverse polarity protectionyes; (VBB30; VBB0, VBB1, VBB2: in case of supply via the on-board system / battery)

Inputs / outputs

Total number of inputs and outputs32

Inputs

Total number of inputs16
Number of frequency inputs4
Number of resistor inputs4
Number of digital inputs16
Number of analogue inputs12
Number4
Plug C2.0IN0400, IN0401; IN0500, IN0501
Frequency inputfunction type; phase; software mode; IN_PHASE_CSO; IN_PHASE_CSI; input pair; A: IN0400 + B: IN0401; A: IN0500 + B: IN0501; input range [V]; 0...32; frequency [Hz]; 0,0625...5000; switching level high [V]; > 70 % VBB30; switching level low [V]; < 30 % VBB30; input resistance [Ω]; 10000; accuracy; ± 10 µs
function typebinary, high side
software modeIN_RESISTOR
input range [V]0...32
frequency [Hz]0,0625...5000
switching level high [V]> 70 % VBB30; (parameterisable)
switching level low [V]< 30 % VBB30; (parameterisable)
input resistance [Ω]3200
accuracy16...3000 Ω: ± 60 Ω
input pairA: IN0400 + B: IN0401
Analogue inputfunction type; Voltage, ratiometric; software mode; IN_VOLTAGE_RATIO; input range [V]; 0...1000 ‰ VBB30; input resistance [Ω]; 51000; Resolution; 12 Bit; accuracy; ± 320 mV; input frequency [Hz]; < 330; diagnostic level low; 0 ‰; (parameterisable); diagnostic level high; 1000 ‰; (parameterisable)
Resolution12 Bit
input frequency [Hz]< 330
diagnostic level low0 Ω; (parameterisable)
diagnostic level high30000 Ω; (parameterisable)
Digital inputfunction type; binary, low-side; software mode; IN_DIGITAL_CSI; IN_DIGITAL_CSI_NAMUR; input range [V]; 0...32; switching level high [V]; > 70 % VBB30; (parameterisable); switching level low [V]; < 30 % VBB30; (parameterisable); Resolution; 12 Bit; accuracy; ± 320 mV; input frequency [Hz]; < 330; input resistance [Ω]; 3200; diagnostic level low; 0 % VBB30; (parameterisable); diagnostic level high; 400 % VBB30; (parameterisable)
Plug C2.2IN0000, IN0001; IN0100, IN0101
Plug C2.3IN0600, IN0601; IN0700, IN0701
input range [mA]0...20
Plug C2.1IN0200, IN0201; IN0300, IN0301
Resistor inputfunction type; binary, high side; software mode; IN_RESISTOR; input range [Ω]; 16...30000; measuring current [mA]; < 2,0; Resolution; 12 Bit; accuracy; 16...3000 Ω: ± 60 Ω; 3000...15000 Ω: ± 750 Ω; 15000...30000 Ω: ± 3000 Ω; diagnostic level low; 0 Ω; (parameterisable); diagnostic level high; 30000 Ω; (parameterisable)
input range [Ω]16...30000
measuring current [mA]< 2,0

Outputs

Total number of outputs16
Number of digital outputs16
Number of PWM outputs12
Number of PWM-I outputs4
Number4
Plug C1.0VBB0, VBB1
Output group switchfunction type; second independent option for safety shut-down of the output group; software mode; OUT_DIGITAL; voltage range [V]; 6...32; voltage measurement [V]; 0...36; accuracy of the voltage measurement [mV]; ± 360; diagnostic function; current monitoring voltage monitoring; Current rating [A]; 10; lower limit of current monitoring [mA]; 0; (parameterisable); upper limit of current monitoring [mA]; 10000; (parameterisable)
function typebinary, high side
software modeOUT_DIGITAL_CSO
voltage range [V]6...32
voltage measurement [V]0...36
accuracy of the voltage measurement [mV]± 360
Current rating [A]10
lower limit of current monitoring [mA]0; (parameterisable)
upper limit of current monitoring [mA]4000; (parameterisable)
Plug C1.2VBB2
diagnostic functionwire break; short circuit; current monitoring
Plug C3.0OUT0002, OUT0003
Plug C3.3OUT0202, OUT0203
PWM outputfunction type; binary, high side; software mode; OUT_PWM_CSO; voltage range [V]; 6...32; switching current [A]; 0,025...1,0; output frequency [Hz]; 20...2000; pulse/pause ratio; 1...1000 ‰; (parameterisable); Resolution; 1 ‰; (20...250 Hz); Min. load resistance [Ω]; 12 V: 12 Ω / 24 V: 24 Ω; protective circuitry; inductive load; thermal protection
switching current [A]0,025...1,0
output frequency [Hz]20...2000
pulse/pause ratio1...1000 ‰; (parameterisable)
Min. load resistance [Ω]12 V: 12 Ω / 24 V: 24 Ω
protective circuitryinductive load; thermal protection
current measurement [A]0...6
accuracy of the current measurement [mA]± 300
diagnostic functionswire break; short circuit; current monitoring
PWM-I outputfunction type; current-controlled; software mode; OUT_CURRENT_CSO; voltage range [V]; 6...32; switching current [A]; 0,025...2,5; output frequency [Hz]; 20...2000; control range [A]; 0,05...2,5; control resolution [mA]; 2; Min. load resistance [Ω]; 12 V: 4,8 Ω / 24 V: 9,6 Ω; protective circuitry; inductive load; thermal protection; current measurement [A]; 0...4; accuracy of the current measurement [mA]; ± 37,5; diagnostic functions; wire break; short circuit; current monitoring; lower limit of current monitoring [mA]; 0; (parameterisable); upper limit of current monitoring [mA]; 2500; (parameterisable)
control range [A]0,05...2,5
control resolution [mA]2
Digital outputfunction type; binary, high side; software mode; OUT_DIGITAL_CSO; voltage range [V]; 6...32; switching current [A]; 0,025...1,0; Min. load resistance [Ω]; 12 V: 12 Ω / 24 V: 24 Ω; protective circuitry; inductive load; thermal protection
Plug C3.2OUT0102, OUT0103
Plug C3.1OUT0004...OUT0007
Resolution1 ‰; (20...250 Hz)

Software / programming

Parameter setting optionsCODESYS 3.5
PLC function to IEC 61131-3yes
Operating systemreal-time operating system

Interfaces

Communication interfaceCAN; Ethernet
Number of CAN interfaces2
Number of Ethernet interfaces1
Transmission rate10 MBit/s; 100 MBit/s
ProtocolTCP/IP; UDP/IP; Modbus TCP
InterfaceCAN Interface 2.0 A/B ISO 11898
Transmission standard10Base-T; 100Base-TX

Operating conditions

Ambient temperature[°C] [°C]-40...85
Note on ambient temperaturefor further details see section Diagrams and graphs
Storage temperature[°C] [°C]-40...85
Max. relative air humidity[%] [%]90; (non condensing)
Max. height above sea level[m] [m]5000
ProtectionIP 20
Pollution degree2
Chemical mediaISO 16750-5; AA, BA, BD, CC, DB, DC, DD; chemical resistance of the plastics; only one chemical permitted at a time
ISO 16750-5AA, BA, BD, CC, DB, DC, DD

Tests / approvals

EMCIEC 61000-6-2; immunity; IEC 61000-6-4; noise emission; ISO 7637-2 pulse 1; severity level 4 / function state C (24 V); ISO 7637-2 pulse 2a; severity level 4 / function state A (24 V); ISO 7637-2 pulse 2b; severity level 4 / function state C (24 V); ISO 7637-2 pulse 3a; severity level 4 / function state A (24 V); ISO 7637-2 pulse 3b; severity level 4 / function state A (24 V); ISO 7637-2 pulse 4; severity level 3 / function state B (12 V); ISO 7637-2 pulse 4; severity level 4 / function state B (24 V); ISO 16750-2 (load dump); function state D (24 V); DIN EN ISO 13766-1; earthworks and construction machines; UN/ECE-R10; noise emission and noise immunity:
IEC 61000-6-2immunity
IEC 61000-6-4noise emission
ISO 7637-2 pulse 1severity level 4 / function state C (24 V)
ISO 7637-2 pulse 2aseverity level 4 / function state A (24 V)
ISO 7637-2 pulse 2bseverity level 4 / function state C (24 V)
ISO 7637-2 pulse 3aseverity level 4 / function state A (24 V)
ISO 7637-2 pulse 3bseverity level 4 / function state A (24 V)
ISO 7637-2 pulse 4severity level 4 / function state B (24 V)
ISO 16750-2 (load dump)function state D (24 V)
DIN EN ISO 13766-1earthworks and construction machines
UN/ECE-R10noise emission and noise immunity:
Continuous shock resistanceISO 16750-3; 30 g 6 ms / 24000 shocks
ISO 16750-330 g 6 ms / 24000 shocks
Vibration resistanceISO 16750-3 Test VII; random, mounting place car body; EN 60068-2-6 sine; 10...500 Hz / 10 cycles/axis, sine
ISO 16750-3 Test VIIrandom, mounting place car body
EN 60068-2-6 sine10...500 Hz / 10 cycles/axis, sine
Climatic testsEN 60068-2-30 damp heat: cyclical; 55 °C upper temperature limit / 6 cycles; EN 60068-2-78 damp heat: constant; 40 °C 93 % rH / test period 21 days
EN 60068-2-30 damp heat: cyclical55 °C upper temperature limit / 6 cycles
EN 60068-2-78 damp heat: constant40 °C 93 % rH / test period 21 days
Electrical safetyIEC 61010-1; safety requirement: general requirements; IEC 61010-2-201; safety requirement: particular requirements for control equipment
IEC 61010-1safety requirement: general requirements
IEC 61010-2-201safety requirement: particular requirements for control equipment
Railway applicationsEN 50121-3-2; EN 50155

Mechanical data

Weight[g] [g]560
Housingrectangular
Type of mountingscrew mounting; (3 x M4)
Dimensions[mm] [mm]162.2 x 139.2 x 25.5
Materialshousing: PPE + PS

Displays / operating elements

Displayconnection; LED, green lights; data transmission; LED, green flashing
Ethernet (ETH0)1 LED, green
status (SYS0)1 LED, multi-colour
status (SYS1)1 LED, multi-colour
status (APP0)1 LED, multi-colour programmable
status (APP1)1 LED, multi-colour programmable
status (APP2)1 LED, multi-colour programmable
no operating system loadedLED (SYS0), green flashing 5 Hz
hardware error fatal error+LED (SYS0), red lights
system error fatal errorLED (SYS0/SYS1), red lights
updateLED (SYS0/SYS1), yellow/green flashing 2 Hz
sleep modeLED (SYS0), blue lights
no applicationLED, green lights
runLED, green flashing 2 Hz
faultLED, red flashing 10 Hz
debug runLED, yellow flashing 2 Hz
debug stopLED, yellow lights
connectionLED, green lights
data transmissionLED, green flashing

Hardware

Processor32-Bit Triple-Core
RAM2,7 MByte RAM
Mass storage9 MByte Flash
Non-volatile memory10 kByte
Boot time≤ 3 s

Remarks

Notesfor use as a safety controller, a separately available licence (CP100S) is required
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: D
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More IFM parts

IFM O8H205Available on requestIFM O8H205
MPN: O8H205 · IFM
Price on request
Request a quote
IFM O8H206Available on requestIFM O8H206
MPN: O8H206 · IFM
Price on request
Request a quote
IFM O8H207Available on requestIFM O8H207
MPN: O8H207 · IFM
Price on request
Request a quote
IFM O8H202Available on requestIFM O8H202
MPN: O8H202 · IFM
Price on request
Request a quote