IFM CR413S
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Controllers for use in cabins and control cabinets |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can CR413S be shipped?
CR413S is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up CR413S in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for CR413S and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for CR413S, subject to availability and destination.
Freely programmable to IEC 61131-3 with CODESYS 3.5 High-performance CAN interface for various communication tasks Multifunctional inputs and current-controlled outputs ensure maximum adaptability Can be used as a safety controller up to SIL2/PL d when combined with a TÜV-certified software package
Specifications
Product characteristics
| Total number of inputs | 16 |
| Total number of outputs | 16 |
| Communication interface | CAN; Ethernet |
| Protection | IP 20 |
Electrical data
| Operating voltage[V] [V] | 8...32 DC |
| Nominal voltage DC[V] [V] | 12 / 24 |
| Power consumption[W] [W] | 4; (VBB30) |
| Reverse polarity protection | yes; (VBB30; VBB0, VBB1, VBB2: in case of supply via the on-board system / battery) |
Inputs / outputs
| Total number of inputs and outputs | 32 |
Inputs
| Total number of inputs | 16 |
| Number of frequency inputs | 4 |
| Number of resistor inputs | 4 |
| Number of digital inputs | 16 |
| Number of analogue inputs | 12 |
| Number | 4 |
| Plug C2.0 | IN0400, IN0401; IN0500, IN0501 |
| Frequency input | function type; phase; software mode; IN_PHASE_CSO; IN_PHASE_CSI; input pair; A: IN0400 + B: IN0401; A: IN0500 + B: IN0501; input range [V]; 0...32; frequency [Hz]; 0,0625...5000; switching level high [V]; > 70 % VBB30; switching level low [V]; < 30 % VBB30; input resistance [Ω]; 10000; accuracy; ± 10 µs |
| function type | binary, high side |
| software mode | IN_RESISTOR |
| input range [V] | 0...32 |
| frequency [Hz] | 0,0625...5000 |
| switching level high [V] | > 70 % VBB30; (parameterisable) |
| switching level low [V] | < 30 % VBB30; (parameterisable) |
| input resistance [Ω] | 3200 |
| accuracy | 16...3000 Ω: ± 60 Ω |
| input pair | A: IN0400 + B: IN0401 |
| Analogue input | function type; Voltage, ratiometric; software mode; IN_VOLTAGE_RATIO; input range [V]; 0...1000 ‰ VBB30; input resistance [Ω]; 51000; Resolution; 12 Bit; accuracy; ± 320 mV; input frequency [Hz]; < 330; diagnostic level low; 0 ‰; (parameterisable); diagnostic level high; 1000 ‰; (parameterisable) |
| Resolution | 12 Bit |
| input frequency [Hz] | < 330 |
| diagnostic level low | 0 Ω; (parameterisable) |
| diagnostic level high | 30000 Ω; (parameterisable) |
| Digital input | function type; binary, low-side; software mode; IN_DIGITAL_CSI; IN_DIGITAL_CSI_NAMUR; input range [V]; 0...32; switching level high [V]; > 70 % VBB30; (parameterisable); switching level low [V]; < 30 % VBB30; (parameterisable); Resolution; 12 Bit; accuracy; ± 320 mV; input frequency [Hz]; < 330; input resistance [Ω]; 3200; diagnostic level low; 0 % VBB30; (parameterisable); diagnostic level high; 400 % VBB30; (parameterisable) |
| Plug C2.2 | IN0000, IN0001; IN0100, IN0101 |
| Plug C2.3 | IN0600, IN0601; IN0700, IN0701 |
| input range [mA] | 0...20 |
| Plug C2.1 | IN0200, IN0201; IN0300, IN0301 |
| Resistor input | function type; binary, high side; software mode; IN_RESISTOR; input range [Ω]; 16...30000; measuring current [mA]; < 2,0; Resolution; 12 Bit; accuracy; 16...3000 Ω: ± 60 Ω; 3000...15000 Ω: ± 750 Ω; 15000...30000 Ω: ± 3000 Ω; diagnostic level low; 0 Ω; (parameterisable); diagnostic level high; 30000 Ω; (parameterisable) |
| input range [Ω] | 16...30000 |
| measuring current [mA] | < 2,0 |
Outputs
| Total number of outputs | 16 |
| Number of digital outputs | 16 |
| Number of PWM outputs | 12 |
| Number of PWM-I outputs | 4 |
| Number | 4 |
| Plug C1.0 | VBB0, VBB1 |
| Output group switch | function type; second independent option for safety shut-down of the output group; software mode; OUT_DIGITAL; voltage range [V]; 6...32; voltage measurement [V]; 0...36; accuracy of the voltage measurement [mV]; ± 360; diagnostic function; current monitoring voltage monitoring; Current rating [A]; 10; lower limit of current monitoring [mA]; 0; (parameterisable); upper limit of current monitoring [mA]; 10000; (parameterisable) |
| function type | binary, high side |
| software mode | OUT_DIGITAL_CSO |
| voltage range [V] | 6...32 |
| voltage measurement [V] | 0...36 |
| accuracy of the voltage measurement [mV] | ± 360 |
| Current rating [A] | 10 |
| lower limit of current monitoring [mA] | 0; (parameterisable) |
| upper limit of current monitoring [mA] | 4000; (parameterisable) |
| Plug C1.2 | VBB2 |
| diagnostic function | wire break; short circuit; current monitoring |
| Plug C3.0 | OUT0002, OUT0003 |
| Plug C3.3 | OUT0202, OUT0203 |
| PWM output | function type; binary, high side; software mode; OUT_PWM_CSO; voltage range [V]; 6...32; switching current [A]; 0,025...1,0; output frequency [Hz]; 20...2000; pulse/pause ratio; 1...1000 ‰; (parameterisable); Resolution; 1 ‰; (20...250 Hz); Min. load resistance [Ω]; 12 V: 12 Ω / 24 V: 24 Ω; protective circuitry; inductive load; thermal protection |
| switching current [A] | 0,025...1,0 |
| output frequency [Hz] | 20...2000 |
| pulse/pause ratio | 1...1000 ‰; (parameterisable) |
| Min. load resistance [Ω] | 12 V: 12 Ω / 24 V: 24 Ω |
| protective circuitry | inductive load; thermal protection |
| current measurement [A] | 0...6 |
| accuracy of the current measurement [mA] | ± 300 |
| diagnostic functions | wire break; short circuit; current monitoring |
| PWM-I output | function type; current-controlled; software mode; OUT_CURRENT_CSO; voltage range [V]; 6...32; switching current [A]; 0,025...2,5; output frequency [Hz]; 20...2000; control range [A]; 0,05...2,5; control resolution [mA]; 2; Min. load resistance [Ω]; 12 V: 4,8 Ω / 24 V: 9,6 Ω; protective circuitry; inductive load; thermal protection; current measurement [A]; 0...4; accuracy of the current measurement [mA]; ± 37,5; diagnostic functions; wire break; short circuit; current monitoring; lower limit of current monitoring [mA]; 0; (parameterisable); upper limit of current monitoring [mA]; 2500; (parameterisable) |
| control range [A] | 0,05...2,5 |
| control resolution [mA] | 2 |
| Digital output | function type; binary, high side; software mode; OUT_DIGITAL_CSO; voltage range [V]; 6...32; switching current [A]; 0,025...1,0; Min. load resistance [Ω]; 12 V: 12 Ω / 24 V: 24 Ω; protective circuitry; inductive load; thermal protection |
| Plug C3.2 | OUT0102, OUT0103 |
| Plug C3.1 | OUT0004...OUT0007 |
| Resolution | 1 ‰; (20...250 Hz) |
Software / programming
| Parameter setting options | CODESYS 3.5 |
| PLC function to IEC 61131-3 | yes |
| Operating system | real-time operating system |
Interfaces
| Communication interface | CAN; Ethernet |
| Number of CAN interfaces | 2 |
| Number of Ethernet interfaces | 1 |
| Transmission rate | 10 MBit/s; 100 MBit/s |
| Protocol | TCP/IP; UDP/IP; Modbus TCP |
| Interface | CAN Interface 2.0 A/B ISO 11898 |
| Transmission standard | 10Base-T; 100Base-TX |
Operating conditions
| Ambient temperature[°C] [°C] | -40...85 |
| Note on ambient temperature | for further details see section Diagrams and graphs |
| Storage temperature[°C] [°C] | -40...85 |
| Max. relative air humidity[%] [%] | 90; (non condensing) |
| Max. height above sea level[m] [m] | 5000 |
| Protection | IP 20 |
| Pollution degree | 2 |
| Chemical media | ISO 16750-5; AA, BA, BD, CC, DB, DC, DD; chemical resistance of the plastics; only one chemical permitted at a time |
| ISO 16750-5 | AA, BA, BD, CC, DB, DC, DD |
Tests / approvals
| EMC | IEC 61000-6-2; immunity; IEC 61000-6-4; noise emission; ISO 7637-2 pulse 1; severity level 4 / function state C (24 V); ISO 7637-2 pulse 2a; severity level 4 / function state A (24 V); ISO 7637-2 pulse 2b; severity level 4 / function state C (24 V); ISO 7637-2 pulse 3a; severity level 4 / function state A (24 V); ISO 7637-2 pulse 3b; severity level 4 / function state A (24 V); ISO 7637-2 pulse 4; severity level 3 / function state B (12 V); ISO 7637-2 pulse 4; severity level 4 / function state B (24 V); ISO 16750-2 (load dump); function state D (24 V); DIN EN ISO 13766-1; earthworks and construction machines; UN/ECE-R10; noise emission and noise immunity: |
| IEC 61000-6-2 | immunity |
| IEC 61000-6-4 | noise emission |
| ISO 7637-2 pulse 1 | severity level 4 / function state C (24 V) |
| ISO 7637-2 pulse 2a | severity level 4 / function state A (24 V) |
| ISO 7637-2 pulse 2b | severity level 4 / function state C (24 V) |
| ISO 7637-2 pulse 3a | severity level 4 / function state A (24 V) |
| ISO 7637-2 pulse 3b | severity level 4 / function state A (24 V) |
| ISO 7637-2 pulse 4 | severity level 4 / function state B (24 V) |
| ISO 16750-2 (load dump) | function state D (24 V) |
| DIN EN ISO 13766-1 | earthworks and construction machines |
| UN/ECE-R10 | noise emission and noise immunity: |
| Continuous shock resistance | ISO 16750-3; 30 g 6 ms / 24000 shocks |
| ISO 16750-3 | 30 g 6 ms / 24000 shocks |
| Vibration resistance | ISO 16750-3 Test VII; random, mounting place car body; EN 60068-2-6 sine; 10...500 Hz / 10 cycles/axis, sine |
| ISO 16750-3 Test VII | random, mounting place car body |
| EN 60068-2-6 sine | 10...500 Hz / 10 cycles/axis, sine |
| Climatic tests | EN 60068-2-30 damp heat: cyclical; 55 °C upper temperature limit / 6 cycles; EN 60068-2-78 damp heat: constant; 40 °C 93 % rH / test period 21 days |
| EN 60068-2-30 damp heat: cyclical | 55 °C upper temperature limit / 6 cycles |
| EN 60068-2-78 damp heat: constant | 40 °C 93 % rH / test period 21 days |
| Electrical safety | IEC 61010-1; safety requirement: general requirements; IEC 61010-2-201; safety requirement: particular requirements for control equipment |
| IEC 61010-1 | safety requirement: general requirements |
| IEC 61010-2-201 | safety requirement: particular requirements for control equipment |
| Railway applications | EN 50121-3-2; EN 50155 |
Mechanical data
| Weight[g] [g] | 560 |
| Housing | rectangular |
| Type of mounting | screw mounting; (3 x M4) |
| Dimensions[mm] [mm] | 162.2 x 139.2 x 25.5 |
| Materials | housing: PPE + PS |
Displays / operating elements
| Display | connection; LED, green lights; data transmission; LED, green flashing |
| Ethernet (ETH0) | 1 LED, green |
| status (SYS0) | 1 LED, multi-colour |
| status (SYS1) | 1 LED, multi-colour |
| status (APP0) | 1 LED, multi-colour programmable |
| status (APP1) | 1 LED, multi-colour programmable |
| status (APP2) | 1 LED, multi-colour programmable |
| no operating system loaded | LED (SYS0), green flashing 5 Hz |
| hardware error fatal error+ | LED (SYS0), red lights |
| system error fatal error | LED (SYS0/SYS1), red lights |
| update | LED (SYS0/SYS1), yellow/green flashing 2 Hz |
| sleep mode | LED (SYS0), blue lights |
| no application | LED, green lights |
| run | LED, green flashing 2 Hz |
| fault | LED, red flashing 10 Hz |
| debug run | LED, yellow flashing 2 Hz |
| debug stop | LED, yellow lights |
| connection | LED, green lights |
| data transmission | LED, green flashing |
Hardware
| Processor | 32-Bit Triple-Core |
| RAM | 2,7 MByte RAM |
| Mass storage | 9 MByte Flash |
| Non-volatile memory | 10 kByte |
| Boot time | ≤ 3 s |
Remarks
| Notes | for use as a safety controller, a separately available licence (CP100S) is required |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: D |